Dwyer A3000-3KPA Photohelic Pressure Switch/Gauge (0-3 kPa)

Model: A3000-3KPA

Dwyer A3000-3KPA Photohelic Pressure Switch/Gauge (0-3 kPa)-

Image is for reference only, refer to product info for complete details.


Downloads: datasheet manual

Dwyer A3000-3KPA Photohelic Pressure Switch/Gauge (0-3 kPa)

Model: A3000-3KPA

Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic® switch/gage set point mechanism. Gage pointer and light shutter are mounted on helix and balancing counterweight.

Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic® switch/gage set point mechanism. Gage pointer and light shutter are mounted on helix and balancing counterweight.

Sale Price $730.31 USD
Regular Price $798.15 USD
Availability 2 to 3 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your Dwyer A3000-3KPA Photohelic Pressure Switch/Gauge (0-3 kPa)

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your Dwyer A3000-3KPA Photohelic Pressure Switch/Gauge (0-3 kPa)

Dwyer A3000-3KPA Offers

The Dwyer A3000-3KPA has a range from 0-3 kPa.

Photohelic® Switch/Gaugesfunction as versatile, highly repeatable pressure switches combined with a precise pressure gauge employing the time-proven Magnehelic® gauge design. The Photohelic® switch/gage measures and controls positive, negative or differential pressures of air and compatible gases. Standard models are rated to 25 psig (1.7 bar) with options to 35 (2.4) or 80 (5.5 bar) psig. Single pressure 36000S models measure to 6000 psig (413 bar) with a 9000 psig (620 bar) rating. Two phototransistor actuated, DPDT relays are included for low/high limit control. Easy to adjust set point indicators are controlled by knobs located on the gauge face. Individual set point deadband is one pointer width - less than 1% of full scale. Set points can be interlocked to provide variable deadband - ideal for control of fans, dampers, etc. Gauge reading is continuous and unaffected by switch operation, even during loss of electrical power. Choose from full scale pressure ranges from a low 0-.25" (0-6 mm) w.c. up to 30 psi (21 bar); single positive pressure to 6000 psig (413 bar).

Photohelic Sensing - How It Works
In typical applications, these Dwyer switch/gages control between high and low pressure set points. When pressure changes, reaching either set point pressure, the infrared light to the limiting phototransistor is cut off by the helix-driven light shutter. The resulting phototransistor signal is electronically amplified to actuate its DPDT slave relay and switching occurs. Dead band between make and break is 1% of full scale or less - just enough to assure positive, chatter-free operation.

Relay-Transformer Features
A plastic housing protects all electronic components. Solid-state and integrated circuit electronics are on glass-epoxy printed circuit boards and self-extinguishing terminal boards.

Features

  • Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic® switch/gage set point mechanism (cover is clear polycarbonate plastic)
  • Gauge pointer and light shutter are mounted on helix and balancing counterweight
  • Shutter passes through slot in optical limit switch to expose phototransistors to integral infrared light source or mask them depending on applied pressure
  • Light shield effectively protects phototransistors from strong outside light sources yet allows free pointer movement; it also gives interior a clean "finished" look
  • Optical limit switches are used for reliability and long service life. Attached directly to set pointers, they are individually aligned to assure precise switching accuracy
  • Semi-flexible drive shaft connects to set point knobs
  • Zero adjustment screw connects to screw in cover to adjust zero pressure reading
  • Plastic enclosure protects electronic components and electrical connections
  • Polycarbonate connection or terminal board is self-extinguishing
  • Glass epoxy printed circuit boards for durability and permanence
  • Load relays are DPDT with latching feature for maximum application versatility
  • Electronics are designed to operate on 50/60 Hz, 120 volt current with 10% over or under voltage
  • Switch set pointers show switch settings at all times
  • Spring loaded friction clutch prevents operator damage of set point mechanism
  • 3-in-1 instrument allows the reduction of several instruments with one product
  • Unique design and 1% full scale dead band provides quick response to pressure changes means no delay in switching and chatter-free operation

Applications

  • Air conditioner systems
  • Clean rooms
  • Fume exhaust systems

Dwyer A3000-3KPA Specifications

Switch Specifications
Switch Type Each set point has 2 Form C relays (DPDT)
Repeatability ±1% of FS
Electrical Rating 10 A at 28 VDC
10 A at 120
240 VAC
Electrical Connections Screw terminals. Use 167°F (75°C) copper conductors only
Power Requirements 120 VAC, 50/60 Hz
240 VAC and 24 VAC power optional
Mounting Orientation Diaphragm in vertical position. Consult factory for other position orientations
Set Point Adjustment Adjustable knobs on face
Agency Approvals CE, CSA, UL
Gauge Specifications
Service Air and non-combustible, compatible gases
Accuracy ±2% of FS at 70°F (21.1°C)
±3% on -0
±4% on -00 models
Pressure Limits -20" Hg to 25 psig (-0.677 to 1.72 bar)
MP option; 35 psig (2.41 bar)
HP option; 80 psig (5.52 bar)
Temperature Limits 20 to 120°F. (-6.67 to 48.9°C)
-20 to 120°F (-28 to 48.9°C) with low temperature option
Process Connections ⅛ female NPT
Dimensions 4" (101.6 mm) dial face
5 x 8¼" (127 x 209.55 mm)
Weight 4 lb (1.81 kg)
Click here for complete specifications on the Dwyer A3000-3KPA

What's included with the Dwyer A3000-3KPA

  • Dwyer A3000-3KPA Photohelic Pressure Switch/Gauge (0-3 kPa)

Ask a question about Dwyer A3000-3KPA Photohelic Pressure Switch/Gauge (0-3 kPa)

Customer Reviews for the Dwyer A3000-3KPA

Dwyer A3000-3KPA Offers

The Dwyer A3000-3KPA has a range from 0-3 kPa.

Photohelic® Switch/Gaugesfunction as versatile, highly repeatable pressure switches combined with a precise pressure gauge employing the time-proven Magnehelic® gauge design. The Photohelic® switch/gage measures and controls positive, negative or differential pressures of air and compatible gases. Standard models are rated to 25 psig (1.7 bar) with options to 35 (2.4) or 80 (5.5 bar) psig. Single pressure 36000S models measure to 6000 psig (413 bar) with a 9000 psig (620 bar) rating. Two phototransistor actuated, DPDT relays are included for low/high limit control. Easy to adjust set point indicators are controlled by knobs located on the gauge face. Individual set point deadband is one pointer width - less than 1% of full scale. Set points can be interlocked to provide variable deadband - ideal for control of fans, dampers, etc. Gauge reading is continuous and unaffected by switch operation, even during loss of electrical power. Choose from full scale pressure ranges from a low 0-.25" (0-6 mm) w.c. up to 30 psi (21 bar); single positive pressure to 6000 psig (413 bar).

Photohelic Sensing - How It Works
In typical applications, these Dwyer switch/gages control between high and low pressure set points. When pressure changes, reaching either set point pressure, the infrared light to the limiting phototransistor is cut off by the helix-driven light shutter. The resulting phototransistor signal is electronically amplified to actuate its DPDT slave relay and switching occurs. Dead band between make and break is 1% of full scale or less - just enough to assure positive, chatter-free operation.

Relay-Transformer Features
A plastic housing protects all electronic components. Solid-state and integrated circuit electronics are on glass-epoxy printed circuit boards and self-extinguishing terminal boards.

Features

  • Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic® switch/gage set point mechanism (cover is clear polycarbonate plastic)
  • Gauge pointer and light shutter are mounted on helix and balancing counterweight
  • Shutter passes through slot in optical limit switch to expose phototransistors to integral infrared light source or mask them depending on applied pressure
  • Light shield effectively protects phototransistors from strong outside light sources yet allows free pointer movement; it also gives interior a clean "finished" look
  • Optical limit switches are used for reliability and long service life. Attached directly to set pointers, they are individually aligned to assure precise switching accuracy
  • Semi-flexible drive shaft connects to set point knobs
  • Zero adjustment screw connects to screw in cover to adjust zero pressure reading
  • Plastic enclosure protects electronic components and electrical connections
  • Polycarbonate connection or terminal board is self-extinguishing
  • Glass epoxy printed circuit boards for durability and permanence
  • Load relays are DPDT with latching feature for maximum application versatility
  • Electronics are designed to operate on 50/60 Hz, 120 volt current with 10% over or under voltage
  • Switch set pointers show switch settings at all times
  • Spring loaded friction clutch prevents operator damage of set point mechanism
  • 3-in-1 instrument allows the reduction of several instruments with one product
  • Unique design and 1% full scale dead band provides quick response to pressure changes means no delay in switching and chatter-free operation

Applications

  • Air conditioner systems
  • Clean rooms
  • Fume exhaust systems

Dwyer A3000-3KPA Specifications

Switch Specifications
Switch Type Each set point has 2 Form C relays (DPDT)
Repeatability ±1% of FS
Electrical Rating 10 A at 28 VDC
10 A at 120
240 VAC
Electrical Connections Screw terminals. Use 167°F (75°C) copper conductors only
Power Requirements 120 VAC, 50/60 Hz
240 VAC and 24 VAC power optional
Mounting Orientation Diaphragm in vertical position. Consult factory for other position orientations
Set Point Adjustment Adjustable knobs on face
Agency Approvals CE, CSA, UL
Gauge Specifications
Service Air and non-combustible, compatible gases
Accuracy ±2% of FS at 70°F (21.1°C)
±3% on -0
±4% on -00 models
Pressure Limits -20" Hg to 25 psig (-0.677 to 1.72 bar)
MP option; 35 psig (2.41 bar)
HP option; 80 psig (5.52 bar)
Temperature Limits 20 to 120°F. (-6.67 to 48.9°C)
-20 to 120°F (-28 to 48.9°C) with low temperature option
Process Connections ⅛ female NPT
Dimensions 4" (101.6 mm) dial face
5 x 8¼" (127 x 209.55 mm)
Weight 4 lb (1.81 kg)
Click here for complete specifications on the Dwyer A3000-3KPA

What's included with the Dwyer A3000-3KPA

  • Dwyer A3000-3KPA Photohelic Pressure Switch/Gauge (0-3 kPa)

Ask a question about Dwyer A3000-3KPA Photohelic Pressure Switch/Gauge (0-3 kPa)

Customer Reviews for the Dwyer A3000-3KPA

More Dwyer Products