Dwyer 636-3 Fixed Range Pressure Transmitter (0-300 psi) with 4-20mA output

Model: 636-3

Dwyer 636-3 Fixed Range Pressure Transmitter (0-300 psi) with 4-20mA output

Model: 636-3

Fixed range, stainless steel transmitter with ±0.30% accuracy. Designed to continuously measure pressure for years in even the toughest environmental and media conditions.

Fixed range, stainless steel transmitter with ±0.30% accuracy. Designed to continuously measure pressure for years in even the toughest environmental and media conditions.

Sale Price $1204.14 USD
Regular Price $1316.00 USD
Availability 5 Days
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your Dwyer 636-3 Fixed Range Pressure Transmitter (0-300 psi) with 4-20mA output

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your Dwyer 636-3 Fixed Range Pressure Transmitter (0-300 psi) with 4-20mA output

Dwyer 636-3 PRESSURE TRANSMITTER, SS, 0-300PSI, FIXED RANGE

  • Fixed range, stainless steel transmitter with ±0.30% accuracy
  • Designed to continuously measure pressure for years in even the toughest environmental and media conditions
  • Select from 4 ranges to 0-300 psig (0-20 bar) with choice of 4-20 mA output
  • Transmitters are explosion-proof, (FM approved) and meet NACE standards for off-shore applications

Specifications

Service: Liquid, gas or vapor.
Wetted Materials: 316L SS.
Fill Fluid: DC 200 Silicone (standard).
Accuracy: ±0.30% of calibrated span.
Stability: ±0.5% of upper range limit for six months.
Temperature Limits: Electronics (ambient): -40 to 140°F (-40 to 60°C); Process interface: -40 to 212°F (-40 to 100°C).
Pressure Limits: 300% upper range limit.
Compensated Temperature Range: -20 to 180°F (-29 to 82°C).
Thermal Effect (includes zero and span): Between -20 and 180°F (-29 and 82°C).
±2.0% per 50°F (28°C).
Power Requirements: 12 to 30 VDC (636), 8 to 14 VDC (636LP), reverse polarity protection.
Output Signal: 4 to 20 mA DC, limited to 30 mA DC (636), 1-5 VDC (636LP).
Zero and Span Adjustments: Null: 4.0 mA ±2% span (636), 1 VDC ±1% span (636LP); Span: 16.0 mA ±1% span (636), 4 VDC ±1% span (636LP).
Loop Resistance: 900 ohms max.
@ 30 V.
Electrical Connection: 3/4" female NPT 24" (61 cm), 22 AWG.
Process Connection: 1/2" female NPT.
Enclosure Rating: NEMA 4 (IP65).
Weight: 0.83 lb (374 g).
Agency Approvals: CE, FM, CSA.
FM and CSA approved explosion-proof for Class I, Division 1, Groups B, C, & D, Class II, Groups E, F, & G, Class III.

Dwyer 636-3 Specifications

Service Liquid, gas or vapor
Wetted Materials 316 L SS
Fill Fluid DC 200 Silicone (standard)
Accuracy ±0.30% of calibrated span
Stability ±0.5% of upper range limit for six months
Temperature Limits Electronics (ambient): -40 to 140°F (-40 to 60°C)
Process interface: -40 to 212°F (-40 to 100°C)
Pressure Limits 300% upper range limit
Compensated Temperature Range -20 to 180°F (-29 to 82°C)
Thermal Effect (includes zero and span) Between -20 and 180°F (-29 and 82°C) ±2.0% per 50°F (28°C)
Power Requirements 12 to 30 VDC (636), 8 to 14 VDC (636LP), reverse polarity protection
Output Signal 4 to 20 mA DC, limited to 30 mA DC (636), 1 to 5 VDC (636LP)
Zero and Span Adjustments Null: 4.0 mA ±2% span (636), 1 VDC ±1% span (636LP)
Span: 16.0 mA ±1% span (636), 4 VDC ±1% span (636LP)
Loop Resistance 900 Ω maximum at 30 V
Electrical Connection 34" NPT 24" (61 cm), 22 AWG
Process Connection ½" NPT
Enclosure Rating NEMA 4 (IP56)
Weight 0.83 lb (374 g)
Agency Approvals CSA, FM. FM and CSA approved explosion-proof for Class I, Division 1, Groups B, C, & D, Class II, Groups E, F, & G, Class III
Click here for complete specifications on the Dwyer 636-3

What's included with the Dwyer 636-3

  • Dwyer 636-3 Fixed Range Pressure Transmitter (0-300 psi) with 4-20mA output

Ask a question about Dwyer 636-3 Fixed Range Pressure Transmitter (0-300 psi) with 4-20mA output

Customer Reviews for the Dwyer 636-3

Dwyer 636-3 PRESSURE TRANSMITTER, SS, 0-300PSI, FIXED RANGE

  • Fixed range, stainless steel transmitter with ±0.30% accuracy
  • Designed to continuously measure pressure for years in even the toughest environmental and media conditions
  • Select from 4 ranges to 0-300 psig (0-20 bar) with choice of 4-20 mA output
  • Transmitters are explosion-proof, (FM approved) and meet NACE standards for off-shore applications

Specifications

Service: Liquid, gas or vapor.
Wetted Materials: 316L SS.
Fill Fluid: DC 200 Silicone (standard).
Accuracy: ±0.30% of calibrated span.
Stability: ±0.5% of upper range limit for six months.
Temperature Limits: Electronics (ambient): -40 to 140°F (-40 to 60°C); Process interface: -40 to 212°F (-40 to 100°C).
Pressure Limits: 300% upper range limit.
Compensated Temperature Range: -20 to 180°F (-29 to 82°C).
Thermal Effect (includes zero and span): Between -20 and 180°F (-29 and 82°C).
±2.0% per 50°F (28°C).
Power Requirements: 12 to 30 VDC (636), 8 to 14 VDC (636LP), reverse polarity protection.
Output Signal: 4 to 20 mA DC, limited to 30 mA DC (636), 1-5 VDC (636LP).
Zero and Span Adjustments: Null: 4.0 mA ±2% span (636), 1 VDC ±1% span (636LP); Span: 16.0 mA ±1% span (636), 4 VDC ±1% span (636LP).
Loop Resistance: 900 ohms max.
@ 30 V.
Electrical Connection: 3/4" female NPT 24" (61 cm), 22 AWG.
Process Connection: 1/2" female NPT.
Enclosure Rating: NEMA 4 (IP65).
Weight: 0.83 lb (374 g).
Agency Approvals: CE, FM, CSA.
FM and CSA approved explosion-proof for Class I, Division 1, Groups B, C, & D, Class II, Groups E, F, & G, Class III.

Dwyer 636-3 Specifications

Service Liquid, gas or vapor
Wetted Materials 316 L SS
Fill Fluid DC 200 Silicone (standard)
Accuracy ±0.30% of calibrated span
Stability ±0.5% of upper range limit for six months
Temperature Limits Electronics (ambient): -40 to 140°F (-40 to 60°C)
Process interface: -40 to 212°F (-40 to 100°C)
Pressure Limits 300% upper range limit
Compensated Temperature Range -20 to 180°F (-29 to 82°C)
Thermal Effect (includes zero and span) Between -20 and 180°F (-29 and 82°C) ±2.0% per 50°F (28°C)
Power Requirements 12 to 30 VDC (636), 8 to 14 VDC (636LP), reverse polarity protection
Output Signal 4 to 20 mA DC, limited to 30 mA DC (636), 1 to 5 VDC (636LP)
Zero and Span Adjustments Null: 4.0 mA ±2% span (636), 1 VDC ±1% span (636LP)
Span: 16.0 mA ±1% span (636), 4 VDC ±1% span (636LP)
Loop Resistance 900 Ω maximum at 30 V
Electrical Connection 34" NPT 24" (61 cm), 22 AWG
Process Connection ½" NPT
Enclosure Rating NEMA 4 (IP56)
Weight 0.83 lb (374 g)
Agency Approvals CSA, FM. FM and CSA approved explosion-proof for Class I, Division 1, Groups B, C, & D, Class II, Groups E, F, & G, Class III
Click here for complete specifications on the Dwyer 636-3

What's included with the Dwyer 636-3

  • Dwyer 636-3 Fixed Range Pressure Transmitter (0-300 psi) with 4-20mA output

Ask a question about Dwyer 636-3 Fixed Range Pressure Transmitter (0-300 psi) with 4-20mA output

Customer Reviews for the Dwyer 636-3

More Dwyer Products

Calibration Lab