Dwyer 2010 Magnehelic Differential Pressure Gauge (0-10"w.c.)

Model: 2010 | Order No: 2010/C | UPC: 094700761583

Dwyer 2010 Magnehelic Differential Pressure Gauge (0-10"w.c.)-

Image is for reference only, refer to product info for complete details.


Downloads: datasheet manual

Dwyer 2010 Magnehelic Differential Pressure Gauge (0-10"w.c.)

Model: 2010 | Order No: 2010/C | UPC: 094700761583

Bezel provides flange for flush mounting in panel. Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.

Bezel provides flange for flush mounting in panel. Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.

Sale Price $83.02 USD
Regular Price $90.73 USD
Availability 2 in Stock
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your 2010 Magnehelic Differential Pressure Gauge (0-10"w.c.)

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your 2010 Magnehelic Differential Pressure Gauge (0-10"w.c.)

Dwyer 2010 Offers

The Dwyer 2001 Differential Pressure Gauge Features a range of 0-10" w.c. and minor divisions of .20.

Select the Magnehelic® gauge for high accuracy--guaranteed within 2% of full scale--and for the wide choice of 81 models available to suit your needs precisely. Using Dwyer's simple, frictionless Magnehelic® gauge movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It's inexpensive, too.

The Magnehelic® gauge is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.

Features

  • Bezel provides flange for flush mounting in panel
  • Clear plastic face is highly resistant to breakage and provides undistorted viewing of pointer and scale
  • Precision litho-printed scale is accurate and easy to read.
  • Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.
  • Pointer stops of molded rubber prevent pointer over-travel without damage.
  • "Wishbone" assembly provides mounting for helix, helix bearings and pointer shaft.
  • Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.
  • Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.
  • Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.
  • Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.
  • Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.
  • Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test. Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.
  • Blowout plug is comprised of a rubber plug on the rear which functions as a relief valve by unseating and venting the gauge interior when over pressure reaches approximately 25 psig (1.7 bar). To provide a free path for pressure relief, there are four spacer pads which maintain 0.023" clearance when gauge is surface mounted. Do not obstruct the gap created by these pads. The blowout plug is not used on models above 180" of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicone for the diaphragm. The blowout plug should not be used as a system overpressure control. High supply pressures may still cause the gauge to fail due to over pressurization, resulting in property damage or serious injury. Good engineering practices should be utilized to prevent your system from exceeding the ratings or any component.
  • O-ring seal for cover assures pressure integrity of case.
  • Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.

Applications

  • Filter Monitoring
  • Air Velocity with Dwyer Pitot Tube
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

Dwyer 2010 Specifications

Service Air and non-combustible, compatible gases (natural gas option available). Note: May be used with hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi
Wetted Materials Consult factory
Housing Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 hour salt spray corrosion test.
Accuracy ±2% (-HA model ±1) of FS (±3% (-HA ±1.5%) on -0, -100PA, -125PA, -10MM and ±4% (-HA ±2%) on -00, -60PA, -6MM ranges), throughout range at 70°F (21.1°C)
Pressure Limits -20 in Hg. to 15 psig.† (-0.677 bar to 1.034 bar); MP option; 35 psig (2.41 bar), HP option; 80 psig (5.52 bar)
Enclosure Rating IP67
Overpressure Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. See Overpressure Protection note on Catalog page
Temperature Limits 20 to 140°F (-6.67 to 60°C). -20°F (-28°C) with low temperature option
Size 4" (101.6 mm) diameter dial face
Mounting Orientation Diaphragm in vertical position. Consult factory for other position orientations
Process Connections 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
Weight 1 lb 2 oz (510 g); MP & HP 2 lb 2 oz (963 g)
Standard Accessories Two 1/8" NPT plugs for duplicate pressure taps, two 1/8" pipe thread to rubber tubing adapters and three flush mounting adapterswith screws. (Mounting and snap ring retainer substituted for three adapters in MP & HP gauge accessories)
Click here for complete specifications on the Dwyer 2010

What's included with the Dwyer 2010

  • Dwyer 2010 Magnehelic Differential Pressure Gauge (0-10"w.c.)

Click on a category to view a selection of compatible accessories with the Dwyer 2010 Magnehelic Differential Pressure Gauge (0-10"w.c.).

Dwyer 160-12 Stainless Steel Pitot Tube (5/16" dia. X 12"L) 160-12
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer A-432 Molded Plastic Carrying Case for Magnehelic gauges A-432
Gray, high-density polyethylene molded carrying case for use with Magnehelic gauges. It comes equipped with 9' (2.7 m) of 3/16" ID rubber tubing, stand-hang bracket, and terminal tube with holder.




Ask a question about Dwyer 2010 Magnehelic Differential Pressure Gauge (0-10"w.c.)

Customer Reviews for the Dwyer 2010

Dwyer 2010 Offers

The Dwyer 2001 Differential Pressure Gauge Features a range of 0-10" w.c. and minor divisions of .20.

Select the Magnehelic® gauge for high accuracy--guaranteed within 2% of full scale--and for the wide choice of 81 models available to suit your needs precisely. Using Dwyer's simple, frictionless Magnehelic® gauge movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It's inexpensive, too.

The Magnehelic® gauge is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.

Features

  • Bezel provides flange for flush mounting in panel
  • Clear plastic face is highly resistant to breakage and provides undistorted viewing of pointer and scale
  • Precision litho-printed scale is accurate and easy to read.
  • Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.
  • Pointer stops of molded rubber prevent pointer over-travel without damage.
  • "Wishbone" assembly provides mounting for helix, helix bearings and pointer shaft.
  • Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.
  • Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.
  • Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.
  • Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.
  • Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.
  • Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test. Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.
  • Blowout plug is comprised of a rubber plug on the rear which functions as a relief valve by unseating and venting the gauge interior when over pressure reaches approximately 25 psig (1.7 bar). To provide a free path for pressure relief, there are four spacer pads which maintain 0.023" clearance when gauge is surface mounted. Do not obstruct the gap created by these pads. The blowout plug is not used on models above 180" of water pressure, medium or high pressure models, or on gauges which require an elastomer other than silicone for the diaphragm. The blowout plug should not be used as a system overpressure control. High supply pressures may still cause the gauge to fail due to over pressurization, resulting in property damage or serious injury. Good engineering practices should be utilized to prevent your system from exceeding the ratings or any component.
  • O-ring seal for cover assures pressure integrity of case.
  • Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.

Applications

  • Filter Monitoring
  • Air Velocity with Dwyer Pitot Tube
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

Dwyer 2010 Specifications

Service Air and non-combustible, compatible gases (natural gas option available). Note: May be used with hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi
Wetted Materials Consult factory
Housing Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 hour salt spray corrosion test.
Accuracy ±2% (-HA model ±1) of FS (±3% (-HA ±1.5%) on -0, -100PA, -125PA, -10MM and ±4% (-HA ±2%) on -00, -60PA, -6MM ranges), throughout range at 70°F (21.1°C)
Pressure Limits -20 in Hg. to 15 psig.† (-0.677 bar to 1.034 bar); MP option; 35 psig (2.41 bar), HP option; 80 psig (5.52 bar)
Enclosure Rating IP67
Overpressure Relief plug opens at approximately 25 psig (1.72 bar), standard gauges only. See Overpressure Protection note on Catalog page
Temperature Limits 20 to 140°F (-6.67 to 60°C). -20°F (-28°C) with low temperature option
Size 4" (101.6 mm) diameter dial face
Mounting Orientation Diaphragm in vertical position. Consult factory for other position orientations
Process Connections 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
Weight 1 lb 2 oz (510 g); MP & HP 2 lb 2 oz (963 g)
Standard Accessories Two 1/8" NPT plugs for duplicate pressure taps, two 1/8" pipe thread to rubber tubing adapters and three flush mounting adapterswith screws. (Mounting and snap ring retainer substituted for three adapters in MP & HP gauge accessories)
Click here for complete specifications on the Dwyer 2010

What's included with the Dwyer 2010

  • Dwyer 2010 Magnehelic Differential Pressure Gauge (0-10"w.c.)

Click on a category to view a selection of compatible accessories with the Dwyer 2010 Magnehelic Differential Pressure Gauge (0-10"w.c.).

Dwyer 160-12 Stainless Steel Pitot Tube (5/16" dia. X 12"L) 160-12
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer A-432 Molded Plastic Carrying Case for Magnehelic gauges A-432
Gray, high-density polyethylene molded carrying case for use with Magnehelic gauges. It comes equipped with 9' (2.7 m) of 3/16" ID rubber tubing, stand-hang bracket, and terminal tube with holder.




Ask a question about Dwyer 2010 Magnehelic Differential Pressure Gauge (0-10"w.c.)

Customer Reviews for the Dwyer 2010

More Dwyer Products