Dracal USB-TRH450-CAL High-Precision USB Temperature and Relative Humidity Sensor with aluminum probe, -40 to 257°F, ±0.18°F

Model: USB-TRH450-CAL | Order No: 608034

Dracal USB-TRH450-CAL High-Precision USB Temperature and Relative Humidity Sensor with aluminum probe, -40 to 257°F, ±0.18°F

Model: USB-TRH450-CAL | Order No: 608034

Ideal for environmental temperature and relative humidity acquisition, this sensor features an aluminum probe and internal filter that protects against dust, soot, and other contaminants. Additionally, this calibratable sensor boasts ±0.18°F (±0.1°C) accuracy and has a USB port that makes it usable in minutes.

Ideal for environmental temperature and relative humidity acquisition, this sensor features an aluminum probe and internal filter that protects against dust, soot, and other contaminants. Additionally, this calibratable sensor boasts ±0.18°F (±0.1°C) accuracy and has a USB port that makes it usable in minutes.

Your Price $279.99 USD
Availability 1 to 2 Weeks
Quantity

Dracal USB-TRH450-CAL Offers

The TRH450, a member of the TRH series, is designed for environmental measurements of temperature and relative humidity with enhanced accuracy of ±0.18°F (±0.1°C) for temperature and ±1.5 %RH for relative humidity. It offers an extended operating range of -40 to 257°F (-40 to 125°C), fine resolution, and robust protection thanks to an anodized aluminum tip and PTFE membrane. Powered via USB with a 1-meter cable, it is ideal for applications requiring precise monitoring in challenging conditions.

Like all Dracal measurement instruments, the TRH450 is compatible with free software tools, making it an essential component of a DAQ solution. For those who wish to integrate the TRH450 into their system, there are two options available: command line tools and VCP mode (VCP- model, sold separately). If you prefer a graphical interface, DracalView is the appropriate choice.

Features

  • 3-point user calibration mechanism available for each of the two measurements
  • Compatible with DracalView GUI and dracal-usb-get CLI
  • Two levels of particulate filters, improving probe life
  • Convenient remote temperature and humidity probe
  • It provides the user with additional data: dew point, humidex, heat index, and altitude
  • Installation time: Less than 10 minutes
  • Free DAQ software: Real-time data visualization and logging
  • Data integration: Command-line tools for direct data access and integration

Applications

  • LIMS integration
  • Test chamber
  • GMP and GLP compliance verification
  • Site supervision
  • Greenhouse
  • Server rooms
  • Manufacturing
  • Pre-certification
  • Humidity control
  • Scientific research
  • Building automation
  • Engineering and R&D
  • Environmental chamber

Dracal USB-TRH450-CAL Specifications

Temperature
Operating Range -40 to 257°F (-40 to 125°C)
Accuracy -40 to 68°F (-40 to 20°C):
Typ.: ±0.36°F (±0.2°C)
Maximum: ±0.54°F (±0.3°C)

68 to 140°F (20 to 60°C):
Typ.: ±0.18°F (±0.1°C)
Maximum: ±0.54°F (±0.3°C)

140 to 257°F (60 to 125°C):
Typ.: ±0.72°F (±0.4°C)
Maximum: ±1.08°F (±0.6°C)

-40 to 257°F (-40 to 125°C):
Typ.: ±0.72°F (±0.4°C)
Maximum: ±1.08°F (±0.6°C)
Resolution Typ.: 0.027°F (0.015°C)
Repeatability Typ.: 0.108°F (0.06°C)
Response Time t63%: 10s
Factory Calibrated Yes, individually
Relative Humidity
Operating Range 0 to 100% RH, non-condensing
Accuracy 0 to 80% RH at 77°F (25°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

80 to 100% RH at 77°F (25°C):
Typ.: ±2% RH
Maximum: ±3% RH

0 to 80% RH from 50 to 122°F (10 to 50°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

0 to 100% RH from 32 to 176°F (0 to 80°C):
Typ.: ±2% RH
Maximum: ±3% RH
Resolution Typ.: 0.01% RH
Hysteresis At 77°F (25°C): 0.8% RH
Factory Calibrated Yes, individually
Probe
Operating Range -40 to 257°F (-40 to 125°C)
Cable Material: Silicon
Length: 3' (1 m)
Filters Material:
Layer 1: Anodized Aluminum
Layer 2: PTFE membrane

Efficiency: 99.99% for particle size ≥200 nm
Housing and USB cable
Operating Range Temperature: 32 to 158°F (0 to 70°C)
Humidity: 10 to 90% RH, non condensing
Material ABS
IP Rating 51
USB Cable Length 3' (1 m)
General Specifications
Voltage Powered through a USB port, 5 V
Current Consumption ≤18 mA at 5V
Colour Cyan
ADC Resolution 16 bits
Long-Term Stability Maximum: 0.03
Temperature Compensated Yes, by the manufacturer
Lifetime 5 years
Weight 1.76 oz (50 g), without USB cable
Click here for complete specifications on the Dracal USB-TRH450-CAL

What's included with the Dracal USB-TRH450-CAL

  • Sensor
  • USB Cable
  • Quick Installation Guide
  • Data Acquisition Solution to Download
  • Two-Year Warranty

Ask a question about Dracal USB-TRH450-CAL High-Precision USB Temperature and Relative Humidity Sensor with aluminum probe, -40 to 257°F, ±0.18°F

Customer Reviews for the Dracal USB-TRH450-CAL

Dracal USB-TRH450-CAL Offers

The TRH450, a member of the TRH series, is designed for environmental measurements of temperature and relative humidity with enhanced accuracy of ±0.18°F (±0.1°C) for temperature and ±1.5 %RH for relative humidity. It offers an extended operating range of -40 to 257°F (-40 to 125°C), fine resolution, and robust protection thanks to an anodized aluminum tip and PTFE membrane. Powered via USB with a 1-meter cable, it is ideal for applications requiring precise monitoring in challenging conditions.

Like all Dracal measurement instruments, the TRH450 is compatible with free software tools, making it an essential component of a DAQ solution. For those who wish to integrate the TRH450 into their system, there are two options available: command line tools and VCP mode (VCP- model, sold separately). If you prefer a graphical interface, DracalView is the appropriate choice.

Features

  • 3-point user calibration mechanism available for each of the two measurements
  • Compatible with DracalView GUI and dracal-usb-get CLI
  • Two levels of particulate filters, improving probe life
  • Convenient remote temperature and humidity probe
  • It provides the user with additional data: dew point, humidex, heat index, and altitude
  • Installation time: Less than 10 minutes
  • Free DAQ software: Real-time data visualization and logging
  • Data integration: Command-line tools for direct data access and integration

Applications

  • LIMS integration
  • Test chamber
  • GMP and GLP compliance verification
  • Site supervision
  • Greenhouse
  • Server rooms
  • Manufacturing
  • Pre-certification
  • Humidity control
  • Scientific research
  • Building automation
  • Engineering and R&D
  • Environmental chamber

Dracal USB-TRH450-CAL Specifications

Temperature
Operating Range -40 to 257°F (-40 to 125°C)
Accuracy -40 to 68°F (-40 to 20°C):
Typ.: ±0.36°F (±0.2°C)
Maximum: ±0.54°F (±0.3°C)

68 to 140°F (20 to 60°C):
Typ.: ±0.18°F (±0.1°C)
Maximum: ±0.54°F (±0.3°C)

140 to 257°F (60 to 125°C):
Typ.: ±0.72°F (±0.4°C)
Maximum: ±1.08°F (±0.6°C)

-40 to 257°F (-40 to 125°C):
Typ.: ±0.72°F (±0.4°C)
Maximum: ±1.08°F (±0.6°C)
Resolution Typ.: 0.027°F (0.015°C)
Repeatability Typ.: 0.108°F (0.06°C)
Response Time t63%: 10s
Factory Calibrated Yes, individually
Relative Humidity
Operating Range 0 to 100% RH, non-condensing
Accuracy 0 to 80% RH at 77°F (25°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

80 to 100% RH at 77°F (25°C):
Typ.: ±2% RH
Maximum: ±3% RH

0 to 80% RH from 50 to 122°F (10 to 50°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

0 to 100% RH from 32 to 176°F (0 to 80°C):
Typ.: ±2% RH
Maximum: ±3% RH
Resolution Typ.: 0.01% RH
Hysteresis At 77°F (25°C): 0.8% RH
Factory Calibrated Yes, individually
Probe
Operating Range -40 to 257°F (-40 to 125°C)
Cable Material: Silicon
Length: 3' (1 m)
Filters Material:
Layer 1: Anodized Aluminum
Layer 2: PTFE membrane

Efficiency: 99.99% for particle size ≥200 nm
Housing and USB cable
Operating Range Temperature: 32 to 158°F (0 to 70°C)
Humidity: 10 to 90% RH, non condensing
Material ABS
IP Rating 51
USB Cable Length 3' (1 m)
General Specifications
Voltage Powered through a USB port, 5 V
Current Consumption ≤18 mA at 5V
Colour Cyan
ADC Resolution 16 bits
Long-Term Stability Maximum: 0.03
Temperature Compensated Yes, by the manufacturer
Lifetime 5 years
Weight 1.76 oz (50 g), without USB cable
Click here for complete specifications on the Dracal USB-TRH450-CAL

What's included with the Dracal USB-TRH450-CAL

  • Sensor
  • USB Cable
  • Quick Installation Guide
  • Data Acquisition Solution to Download
  • Two-Year Warranty

Ask a question about Dracal USB-TRH450-CAL High-Precision USB Temperature and Relative Humidity Sensor with aluminum probe, -40 to 257°F, ±0.18°F

Customer Reviews for the Dracal USB-TRH450-CAL

More Dracal Products

Calibration Lab