Dracal USB-TRH420-CAL Precision USB Temperature and Relative Humidity Sensor with 2-layer filter, -40 to 158°F, ±0.18°F

Model: USB-TRH420-CAL | Order No: 608033

Dracal USB-TRH420-CAL Precision USB Temperature and Relative Humidity Sensor with 2-layer filter, -40 to 158°F, ±0.18°F

Model: USB-TRH420-CAL | Order No: 608033

Ideal for environmental temperature and relative humidity acquisition, this sensor features a 2-layer filter that protects against dust, soot, and other contaminants. Additionally, this calibratable sensor boasts ±0.18°F (±0.1°C) accuracy and has a USB port that makes it usable in minutes.

Ideal for environmental temperature and relative humidity acquisition, this sensor features a 2-layer filter that protects against dust, soot, and other contaminants. Additionally, this calibratable sensor boasts ±0.18°F (±0.1°C) accuracy and has a USB port that makes it usable in minutes.

Your Price $246.99 USD
Availability 2 to 3 Weeks
Quantity

Dracal USB-TRH420-CAL Offers

The TRH420, a member of the TRH series, is a USB sensor designed for environmental temperature and relative humidity measurements, offering improved precision of ±0.18°F (±0.1°C) for temperature and ±1.5%RH for relative humidity. Its digitally calibrated, linearized, and factory-compensated sensor allows precise and interchangeable measurements, with a probe operating range of 40 to 158°F (-40 to 70°C). With a resolution of 0.027°F (0.015°C) for temperature and 0.01% RH for relative humidity, it is ideally suited for applications requiring precise monitoring of these parameters. Its 1-meter USB cable and USB-powered operation provide excellent installation flexibility, while its robust design protects it against challenging environmental conditions.

Like all Dracal measurement instruments, the TRH420 is compatible with free software tools, making it an essential component of a DAQ solution. For those who wish to integrate the TRH420 into their system, there are two options available: command line tools and VCP mode (VCP- model, sold separately). If you prefer a graphical interface, DracalView is the appropriate choice.

Features

  • 3-point user calibration mechanism available for each of the two measurements
  • Compatible with DracalView GUI and dracal-usb-get CLI
  • Two levels of particulate filters, improving probe life
  • Convenient remote temperature and humidity probe
  • It provides the user with additional data: dew point, humidex, heat index, and altitude
  • Installation time: Less than 10 minutes
  • Free DAQ software: Real-time data visualization and logging
  • Data integration: Command-line tools for direct data access and integration

Applications

  • LIMS integration
  • Weather station
  • GMP and GLP compliance verification
  • Environmental studies
  • Greenhouse
  • Server rooms
  • Manufacturing
  • Pre-certification
  • Humidity control
  • Scientific research
  • Building automation
  • Engineering and R&D
  • Environmental chamber

Dracal USB-TRH420-CAL Specifications

Temperature
Operating Range -40 to 158°F (-40 to 70°C)
Accuracy -40 to 68°F (-40 to 20°C):
Typ.: ±0.36°F (±0.2°C)
Maximum: ±0.54°F (±0.3°C)

68 to 140°F (20 to 60°C):
Typ.: ±0.18°F (±0.1°C)
Maximum: ±0.54°F (±0.3°C)

140 to 158°F (60 to 70°C):
Typ.: ±0.27°F (±0.15°C)
Maximum: ±0.54°F (±0.3°C)

-40 to 158°F (-40 to 70°C):
Typ.: ±0.36°F (±0.2°C)
Maximum: ±0.54°F (±0.3°C)
Resolution Typ.: 0.027°F (0.015°C)
Repeatability Typ.: 0.108°F (0.06°C)
Response Time t63%: 10s
Factory Calibrated Yes, individually
Relative Humidity
Operating Range 0 to 100% RH, non-condensing
Accuracy 0 to 80% RH at 77°F (25°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

80 to 100 % RH at 77°F (25°C):
Typ.: ±2% RH
Maximum: ±3% RH

0 to 80% RH from 50 to 122°F (10 to 50°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

0 to 100% RH from 32 to 158°F (0 to 70°C):
Typ.: ±2% RH
Maximum: ±3% RH
Resolution Typ.: 0.01% RH
Hysteresis At 77°F (25°C): 0.8% RH
Factory Calibrated Yes, individually
Probe
Operating Range -40 to 158°F (-40 to 70°C)
Cable Material: PVC
Length: 3' (1 m)
Filters Material:
Layer 1: Polyethylene terephthalate (PET) mesh
Layer 2: PTFE membrane

Efficiency: 99.99% for particle size ≥200 nm
Housing and USB cable
Operating Range Temperature: 32 to 158°F (0 to 70°C)
Humidity: 10 to 90% RH, non condensing
Material ABS
IP Rating 51
USB Cable Length 3' (1 m)
General Specifications
Voltage Powered through a USB port, 5 V
Current Consumption ≤18 mA at 5V
Colour Cyan
ADC Resolution 16 bits
Long-Term Stability Yes
Temperature Compensated Yes, by the manufacturer
Lifetime 5 years
Weight 1.41 oz (40 g), without USB cable
Click here for complete specifications on the Dracal USB-TRH420-CAL

What's included with the Dracal USB-TRH420-CAL

  • Sensor
  • USB Cable
  • Quick Installation Guide
  • Data Acquisition Solution to Download
  • Two-Year Warranty

Ask a question about Dracal USB-TRH420-CAL Precision USB Temperature and Relative Humidity Sensor with 2-layer filter, -40 to 158°F, ±0.18°F

Customer Reviews for the Dracal USB-TRH420-CAL

Dracal USB-TRH420-CAL Offers

The TRH420, a member of the TRH series, is a USB sensor designed for environmental temperature and relative humidity measurements, offering improved precision of ±0.18°F (±0.1°C) for temperature and ±1.5%RH for relative humidity. Its digitally calibrated, linearized, and factory-compensated sensor allows precise and interchangeable measurements, with a probe operating range of 40 to 158°F (-40 to 70°C). With a resolution of 0.027°F (0.015°C) for temperature and 0.01% RH for relative humidity, it is ideally suited for applications requiring precise monitoring of these parameters. Its 1-meter USB cable and USB-powered operation provide excellent installation flexibility, while its robust design protects it against challenging environmental conditions.

Like all Dracal measurement instruments, the TRH420 is compatible with free software tools, making it an essential component of a DAQ solution. For those who wish to integrate the TRH420 into their system, there are two options available: command line tools and VCP mode (VCP- model, sold separately). If you prefer a graphical interface, DracalView is the appropriate choice.

Features

  • 3-point user calibration mechanism available for each of the two measurements
  • Compatible with DracalView GUI and dracal-usb-get CLI
  • Two levels of particulate filters, improving probe life
  • Convenient remote temperature and humidity probe
  • It provides the user with additional data: dew point, humidex, heat index, and altitude
  • Installation time: Less than 10 minutes
  • Free DAQ software: Real-time data visualization and logging
  • Data integration: Command-line tools for direct data access and integration

Applications

  • LIMS integration
  • Weather station
  • GMP and GLP compliance verification
  • Environmental studies
  • Greenhouse
  • Server rooms
  • Manufacturing
  • Pre-certification
  • Humidity control
  • Scientific research
  • Building automation
  • Engineering and R&D
  • Environmental chamber

Dracal USB-TRH420-CAL Specifications

Temperature
Operating Range -40 to 158°F (-40 to 70°C)
Accuracy -40 to 68°F (-40 to 20°C):
Typ.: ±0.36°F (±0.2°C)
Maximum: ±0.54°F (±0.3°C)

68 to 140°F (20 to 60°C):
Typ.: ±0.18°F (±0.1°C)
Maximum: ±0.54°F (±0.3°C)

140 to 158°F (60 to 70°C):
Typ.: ±0.27°F (±0.15°C)
Maximum: ±0.54°F (±0.3°C)

-40 to 158°F (-40 to 70°C):
Typ.: ±0.36°F (±0.2°C)
Maximum: ±0.54°F (±0.3°C)
Resolution Typ.: 0.027°F (0.015°C)
Repeatability Typ.: 0.108°F (0.06°C)
Response Time t63%: 10s
Factory Calibrated Yes, individually
Relative Humidity
Operating Range 0 to 100% RH, non-condensing
Accuracy 0 to 80% RH at 77°F (25°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

80 to 100 % RH at 77°F (25°C):
Typ.: ±2% RH
Maximum: ±3% RH

0 to 80% RH from 50 to 122°F (10 to 50°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

0 to 100% RH from 32 to 158°F (0 to 70°C):
Typ.: ±2% RH
Maximum: ±3% RH
Resolution Typ.: 0.01% RH
Hysteresis At 77°F (25°C): 0.8% RH
Factory Calibrated Yes, individually
Probe
Operating Range -40 to 158°F (-40 to 70°C)
Cable Material: PVC
Length: 3' (1 m)
Filters Material:
Layer 1: Polyethylene terephthalate (PET) mesh
Layer 2: PTFE membrane

Efficiency: 99.99% for particle size ≥200 nm
Housing and USB cable
Operating Range Temperature: 32 to 158°F (0 to 70°C)
Humidity: 10 to 90% RH, non condensing
Material ABS
IP Rating 51
USB Cable Length 3' (1 m)
General Specifications
Voltage Powered through a USB port, 5 V
Current Consumption ≤18 mA at 5V
Colour Cyan
ADC Resolution 16 bits
Long-Term Stability Yes
Temperature Compensated Yes, by the manufacturer
Lifetime 5 years
Weight 1.41 oz (40 g), without USB cable
Click here for complete specifications on the Dracal USB-TRH420-CAL

What's included with the Dracal USB-TRH420-CAL

  • Sensor
  • USB Cable
  • Quick Installation Guide
  • Data Acquisition Solution to Download
  • Two-Year Warranty

Ask a question about Dracal USB-TRH420-CAL Precision USB Temperature and Relative Humidity Sensor with 2-layer filter, -40 to 158°F, ±0.18°F

Customer Reviews for the Dracal USB-TRH420-CAL

More Dracal Products

Calibration Lab