Versatile and compact, this spectrum USB features three sensors capable of measuring five bands of light (ultraviolet, ambient light, color, infrared, and large white light band). Moreover, this calibratable set of sensors is sensitive, stable, and factory temperature compensated for a minimum temperature offset.
Versatile and compact, this spectrum USB features three sensors capable of measuring five bands of light (ultraviolet, ambient light, color, infrared, and large white light band). Moreover, this calibratable set of sensors is sensitive, stable, and factory temperature compensated for a minimum temperature offset.
The SPECTRUM100 is a versatile USB light sensor that simultaneously detects white light, colours (RGB), ultraviolet A and B, infrared, and ambient light, offering various functionalities.
Built around specialized, high-quality sensors, the SPECTRUM100 provides exceptional accuracy and reliable stability in various environments. It supports a wide detection range from 0.0072 to 120,000 lux for ambient and white light, 0 to 20,000 lux for colour and infrared, and offers optimal sensitivity for ultraviolet A and B. Its compact design, USB compatibility, and sturdy construction make it an ideal tool for scientists and engineers.
Like all Dracal measurement instruments, the SPECTRUM100 is compatible with free software tools, making it an essential component of a DAQ solution. For those who wish to integrate the SPECTRUM100 into their system, there are two options available: command line tools and VCP mode (VCP- model, sold separately). If you prefer a graphical interface, DracalView is the appropriate choice.
Features
Applications
ALS | |
Detection Range | 0 to 120,000 lx |
Digital Resolution | 0.072 lx/step |
Dynamic Range | 16 bit |
Tolerance | ≤10% |
Flicker Noise Rejection | 100, 120 Hz |
Dark Offset | Dark light, 3 steps |
Light Spectral Response | Peak: 550 nm |
Built-in Algorithms | Filtron™ |
White Light | |
Detection Range | 0 to 120,000 lx |
Digital Resolution | 0.0072 lx/step |
Dynamic Range | 16 bit |
Tolerance | ≤10% |
Flicker Noise Rejection | 100, 120 Hz |
Dark Offset | Dark light, 3 steps |
Light Spectral Response | Peak: 600 nm |
Built-in Algorithms | O-Trim™ |
Colour (RGB) and Infrared Light | |
Detection Range | Green ch., It = 40mS: 0 to 16,496 lx |
Digital Resolution | 0.007865 lx/step |
Resolution | 16 bit, each channel |
Built-in Algorithms | Filtron™ |
Irradiance Responsivity | 96, 74, 56 counts/μW/cm2 |
RGB Spectral | Response: Typical peak: 650, 550, 450 nm Bandwidth: λ 0.5 ±35, ±35, ±40 nm |
IR Spectral Response | Peak: 850 nm |
Dark Offset | Maximum: 3 steps |
Ultraviolet A and B Light | |
UVA | Responsivity: 0.93 counts/μW/cm2 Spectral response: Peak at 365 nm Spectral bandwidth range: ±10 nm |
UVB | Responsivity: 2.1 counts/μW/cm2 Spectral response: Peak at 330 nm Spectral bandwidth range: ±10 nm |
Resolution | Up to 65536 counts, 16 bits |
Housing and USB Cable | |
Operating Range | Temperature: 32 to 158°F (0 to 70°C) Humidity: Non condensing, 10 to 90% RH |
Material | ABS |
IP Rating | 51 |
USB Cable Length | 3' (1 m) |
Communication | |
Interface | USB 2.0 |
USB Cable Length | Maximum: 6.56' (2 m) |
General Specifications | |
Angle of Half Sensitivity | 55° |
Voltage | Powered through a USB port, 5 V |
Current Consumption | Maximum, at 5V, 25 mA |
Colour | Black |
Dimensions | 2.76 x 0.79 x 0.39" (7 x 2 x 1 cm) |
Weight | 0.28 oz (8 g) |
ALS | |
Detection Range | 0 to 120,000 lx |
Digital Resolution | 0.072 lx/step |
Dynamic Range | 16 bit |
Tolerance | ≤10% |
Flicker Noise Rejection | 100, 120 Hz |
Dark Offset | Dark light, 3 steps |
Light Spectral Response | Peak: 550 nm |
Built-in Algorithms | Filtron™ |
White Light | |
Detection Range | 0 to 120,000 lx |
Digital Resolution | 0.0072 lx/step |
Dynamic Range | 16 bit |
Tolerance | ≤10% |
Flicker Noise Rejection | 100, 120 Hz |
Dark Offset | Dark light, 3 steps |
Light Spectral Response | Peak: 600 nm |
Built-in Algorithms | O-Trim™ |
Colour (RGB) and Infrared Light | |
Detection Range | Green ch., It = 40mS: 0 to 16,496 lx |
Digital Resolution | 0.007865 lx/step |
Resolution | 16 bit, each channel |
Built-in Algorithms | Filtron™ |
Irradiance Responsivity | 96, 74, 56 counts/μW/cm2 |
RGB Spectral | Response: Typical peak: 650, 550, 450 nm Bandwidth: λ 0.5 ±35, ±35, ±40 nm |
IR Spectral Response | Peak: 850 nm |
Dark Offset | Maximum: 3 steps |
Ultraviolet A and B Light | |
UVA | Responsivity: 0.93 counts/μW/cm2 Spectral response: Peak at 365 nm Spectral bandwidth range: ±10 nm |
UVB | Responsivity: 2.1 counts/μW/cm2 Spectral response: Peak at 330 nm Spectral bandwidth range: ±10 nm |
Resolution | Up to 65536 counts, 16 bits |
Housing and USB Cable | |
Operating Range | Temperature: 32 to 158°F (0 to 70°C) Humidity: Non condensing, 10 to 90% RH |
Material | ABS |
IP Rating | 51 |
USB Cable Length | 3' (1 m) |
Communication | |
Interface | USB 2.0 |
USB Cable Length | Maximum: 6.56' (2 m) |
General Specifications | |
Angle of Half Sensitivity | 55° |
Voltage | Powered through a USB port, 5 V |
Current Consumption | Maximum, at 5V, 25 mA |
Colour | Black |
Dimensions | 2.76 x 0.79 x 0.39" (7 x 2 x 1 cm) |
Weight | 0.28 oz (8 g) |