Dracal USB-I2C-SPS30 Adapter for Particulate Matter Sensor, I2C to USB, 400 kHz

Model: USB-I2C-SPS30 | Order No: 612001

Dracal USB-I2C-SPS30 Adapter for Particulate Matter Sensor, I2C to USB, 400 kHz

Model: USB-I2C-SPS30 | Order No: 612001

Designed for real-time data acquisition, this USB adapter for the SPS30 particulate matter sensor is ideal for indoor air quality monitoring. Moreover, this converter comes with downloadable software that automatically identifies the SPS30 and is suitable with PCs and most Android devices with an available USB port.

Designed for real-time data acquisition, this USB adapter for the SPS30 particulate matter sensor is ideal for indoor air quality monitoring. Moreover, this converter comes with downloadable software that automatically identifies the SPS30 and is suitable with PCs and most Android devices with an available USB port.

Your Price $128.99 USD
Availability 2 to 3 Weeks
Quantity

Dracal USB-I2C-SPS30 Offers

The USB-I2C-SPS30 is an I2C to USB converter designed for the Sensirion SPS30 particle sensor, offering fast communication with a PC via USB 2.0. It allows fast sampling (10 per second) and is powered via the USB port, with low current consumption (15 mA). Compact and lightweight, it is suitable for portable use but is not waterproof. It operates from 32 to 158°F (0 to 70°C) and a humidity level of 10 to 90% RH.

Like all Dracal measurement instruments, the USB-I2C-SPS30 is compatible with free software tools, making it an essential component of a DAQ solution. For those who wish to integrate the USB-I2C-SPS30 into their system, command line tools are available. If you prefer a graphical interface, DracalView is the appropriate choice.

Features

  • I2C converter
  • Compatible with DracalView GUI and dracal-usb-get CLI
  • Compatible with Sensirion SPS30
  • Detects particle sizes of 0.3 to 10 μM
  • Installation time: Less than 10 minutes
  • Free DAQ software: Real-time data visualization and logging
  • Data integration: Command-line tools for direct data access and integration

Applications

  • Indoor air quality
  • Warehouses
  • Monitoring and control of processes
  • LIMS integration
  • Greenhouse
  • Server rooms
  • Manufacturing
  • Scientific research
  • Building automation
  • Engineering and R&D

Dracal USB-I2C-SPS30 Specifications

USB Adapter Specifications
Operating Range Temperature: 32 to 158°F (0 to 70°C)
Humidity: 10 to 90 % RH, non-condensing
Sensor Wires Length 2.76" (7 cm)
Communication Interface Computer side: USB
Sensor side: I2C
I2C Speed: 400 kHz
Maximum sampling rate: 10 samples/second
Material ABS
IP Rating 51
USB Cable Length 3' (1 m)
Color Cyan
Maximum USB Cable Length 6.56' (2 m)
Power Supply Voltage Powered through a USB port, 5 V
Current Consumption At 5V, 15 mA
Certification RoHS
Dimensions Housing: 34.65 x 11.02 x 5.51" (88 x 28 x 14 cm)
Weight 0.85 oz (24 g), without USB cable
SPS30 Specifications
Mass Concentration Range: 0 to 1000 μg/m³

Size range
PM1.0: 0.3 to 1μm
PM2.5: 0.3 to 2.5 μm
PM4: 0.3 to 4 μm
PM104: 0.3 to 10 μm
Mass Concentration Precision 1, 2 PM1 and PM2.5
0 to 100 μg/m³: ±10 μg/m³
100 to 1000 μg/m³: ±10% m.v.

PM4 and PM10
0 to 100 μg/m³: ±25 μg/m³
100 to 1000 μg/m³: ±25% m.v
Maximum Long-term Mass Concentration Precision Limit Drift 0 to 100 μg/m³: ±1.25 μg/m³/year
100 to 1000 μg/m³: ±1.25% m.v./year
Number Concentration Range: 0 to 3000 #/cm³

Size range
PM0.5: 0.3 to 0.5 μm
PM1.0: 0.3 to 1 μm
PM2.5: 0.3 to 2.5 μm
PM4: 0.3 to 4 μm
PM10: 0.3 to 10 μm
Number Concentration Precision 1, 2 PM0.5, PM1, PM2.5
0 to 1000 #/cm³: ±100 #/cm³
1000 to 3000 #/cm³: ±10% m.v.

PM4, PM10
0 to 1000 #/cm³: ±250 #/cm³
1000 to 3000 #/cm³: ±25% m.v.
Maximum Long-term Number Concentration Precision Limit Drift2 0 to 1000 #/cm³: ±12.5 #/cm³/year
1000 to 3000 #/cm³: ±1.25% m.v./year
Sampling Interval 1 ±0.04 s
Typical Start-up Time5 (number concentration) 200 to 3000 #/cm³: 8 s
100 to 200 #/cm³: 16 s
50 to 100 #/cm³: 30 s
Sensor Output Characteristics PM2.5 mass concentration: Calibrated to TSI DustTrak™ DRX 8533 Ambient Mode
PM2.5 number concentration: Calibrated to TSI OPS 3330
Lifetime 24 hour/day operation: >10 years
Acoustic Emission Level 25 dB(A) at 0.2 m maximum
Long-term Acoustic Emission Level Drift +0.5 dB(A)/year at 0.2 m maximum
Additional T-Dependent mass and number concentration precision limit drift2 Temperature difference to 77°F (25°C): typ. ±0.5% m.v.
Voltage 4.5 to 5.5 V
Current Consumption Maximum/ at 5V: 80 mA
Weight Approximately 0.93 oz (26.3 g)
Click here for complete specifications on the Dracal USB-I2C-SPS30

What's included with the Dracal USB-I2C-SPS30

  • Adapter
  • Quick Installation Guide
  • Data Acquisition Solution to Download
  • Two-Year Warranty

Ask a question about Dracal USB-I2C-SPS30 Adapter for Particulate Matter Sensor, I2C to USB, 400 kHz

Customer Reviews for the Dracal USB-I2C-SPS30

Dracal USB-I2C-SPS30 Offers

The USB-I2C-SPS30 is an I2C to USB converter designed for the Sensirion SPS30 particle sensor, offering fast communication with a PC via USB 2.0. It allows fast sampling (10 per second) and is powered via the USB port, with low current consumption (15 mA). Compact and lightweight, it is suitable for portable use but is not waterproof. It operates from 32 to 158°F (0 to 70°C) and a humidity level of 10 to 90% RH.

Like all Dracal measurement instruments, the USB-I2C-SPS30 is compatible with free software tools, making it an essential component of a DAQ solution. For those who wish to integrate the USB-I2C-SPS30 into their system, command line tools are available. If you prefer a graphical interface, DracalView is the appropriate choice.

Features

  • I2C converter
  • Compatible with DracalView GUI and dracal-usb-get CLI
  • Compatible with Sensirion SPS30
  • Detects particle sizes of 0.3 to 10 μM
  • Installation time: Less than 10 minutes
  • Free DAQ software: Real-time data visualization and logging
  • Data integration: Command-line tools for direct data access and integration

Applications

  • Indoor air quality
  • Warehouses
  • Monitoring and control of processes
  • LIMS integration
  • Greenhouse
  • Server rooms
  • Manufacturing
  • Scientific research
  • Building automation
  • Engineering and R&D

Dracal USB-I2C-SPS30 Specifications

USB Adapter Specifications
Operating Range Temperature: 32 to 158°F (0 to 70°C)
Humidity: 10 to 90 % RH, non-condensing
Sensor Wires Length 2.76" (7 cm)
Communication Interface Computer side: USB
Sensor side: I2C
I2C Speed: 400 kHz
Maximum sampling rate: 10 samples/second
Material ABS
IP Rating 51
USB Cable Length 3' (1 m)
Color Cyan
Maximum USB Cable Length 6.56' (2 m)
Power Supply Voltage Powered through a USB port, 5 V
Current Consumption At 5V, 15 mA
Certification RoHS
Dimensions Housing: 34.65 x 11.02 x 5.51" (88 x 28 x 14 cm)
Weight 0.85 oz (24 g), without USB cable
SPS30 Specifications
Mass Concentration Range: 0 to 1000 μg/m³

Size range
PM1.0: 0.3 to 1μm
PM2.5: 0.3 to 2.5 μm
PM4: 0.3 to 4 μm
PM104: 0.3 to 10 μm
Mass Concentration Precision 1, 2 PM1 and PM2.5
0 to 100 μg/m³: ±10 μg/m³
100 to 1000 μg/m³: ±10% m.v.

PM4 and PM10
0 to 100 μg/m³: ±25 μg/m³
100 to 1000 μg/m³: ±25% m.v
Maximum Long-term Mass Concentration Precision Limit Drift 0 to 100 μg/m³: ±1.25 μg/m³/year
100 to 1000 μg/m³: ±1.25% m.v./year
Number Concentration Range: 0 to 3000 #/cm³

Size range
PM0.5: 0.3 to 0.5 μm
PM1.0: 0.3 to 1 μm
PM2.5: 0.3 to 2.5 μm
PM4: 0.3 to 4 μm
PM10: 0.3 to 10 μm
Number Concentration Precision 1, 2 PM0.5, PM1, PM2.5
0 to 1000 #/cm³: ±100 #/cm³
1000 to 3000 #/cm³: ±10% m.v.

PM4, PM10
0 to 1000 #/cm³: ±250 #/cm³
1000 to 3000 #/cm³: ±25% m.v.
Maximum Long-term Number Concentration Precision Limit Drift2 0 to 1000 #/cm³: ±12.5 #/cm³/year
1000 to 3000 #/cm³: ±1.25% m.v./year
Sampling Interval 1 ±0.04 s
Typical Start-up Time5 (number concentration) 200 to 3000 #/cm³: 8 s
100 to 200 #/cm³: 16 s
50 to 100 #/cm³: 30 s
Sensor Output Characteristics PM2.5 mass concentration: Calibrated to TSI DustTrak™ DRX 8533 Ambient Mode
PM2.5 number concentration: Calibrated to TSI OPS 3330
Lifetime 24 hour/day operation: >10 years
Acoustic Emission Level 25 dB(A) at 0.2 m maximum
Long-term Acoustic Emission Level Drift +0.5 dB(A)/year at 0.2 m maximum
Additional T-Dependent mass and number concentration precision limit drift2 Temperature difference to 77°F (25°C): typ. ±0.5% m.v.
Voltage 4.5 to 5.5 V
Current Consumption Maximum/ at 5V: 80 mA
Weight Approximately 0.93 oz (26.3 g)
Click here for complete specifications on the Dracal USB-I2C-SPS30

What's included with the Dracal USB-I2C-SPS30

  • Adapter
  • Quick Installation Guide
  • Data Acquisition Solution to Download
  • Two-Year Warranty

Ask a question about Dracal USB-I2C-SPS30 Adapter for Particulate Matter Sensor, I2C to USB, 400 kHz

Customer Reviews for the Dracal USB-I2C-SPS30

More Dracal Products