Dent PS24HD-C-D-N-C PowerScout 24 HD Multi-Circuit Power Submeter, with enclosure, display, CTEP

Model: PS24HD-C-D-N-C

Dent PS24HD-C-D-N-C PowerScout 24 HD Multi-Circuit Power Submeter, with enclosure, display, CTEP

Model: PS24HD-C-D-N-C

Networked electrical submetering provides meaningful energy data that is used to accurately allocate energy costs, identify energy cost-savings opportunities, and lower utility bills. The flexible design of the PowerScout 24 HD allows it to monitor voltage, current, power, energy, and many other electrical parameters on any combination of up to 8 three-phase or 24 single-phase electrical devices with a single multi-circuit submeter. Before a submeter can be used for billing applications in California, CTEP-approved meters and CTEP-compliant CTs must be ordered. Comes with a UL 94-V0 enclosure and display.

Networked electrical submetering provides meaningful energy data that is used to accurately allocate energy costs, identify energy cost-savings opportunities, and lower utility bills. The flexible design of the PowerScout 24 HD allows it to monitor voltage, current, power, energy, and many other electrical parameters on any combination of up to 8 three-phase or 24 single-phase electrical devices with a single multi-circuit submeter. Before a submeter can be used for billing applications in California, CTEP-approved meters and CTEP-compliant CTs must be ordered. Comes with a UL 94-V0 enclosure and display.

Sale Price $1868.65 USD
Regular Price $2540.00 USD
Availability 2 to 3 Weeks
Quantity

Dent PS24HD-C-D-N-C Offers

Maximum flexibility for monitoring

The PowerScout 24 HD is a multi-circuit submeter that monitors a variety of electrical parameters on any combination of single and/or three-phase systems. With data updates every 1 second and ANSI C12.20-2010 Class 0.2 revenue-grade accuracy (depending on CT), the PowerScout 24 HD is well-suited for data center monitoring, tenant submetering, and accountability metering in commercial, retail, and industrial facilities

Industry-standard modbus or bacnet

The PowerScout 24 HD supports both Modbus and BACnet communications protocols which are field-selectable. Communication interfaces are available through standard serial RS-485 or Ethernet, using either Modbus, BACnet MS/TP, Modbus TCP, or BACnet IP protocols. PowerScout 24 HD meters are equipped with two independent dry-contact pulse inputs, allowing for monitoring of customer-derived voltage networks. Configure each of the input channels independently with customizable units of measure (i.e., gallons) within ViewPoint HD software.

Interval data recording and RTC

The PowerScout HD Series features interval data recording of kWh. The meter’s non-volatile memory stores up to 63 days of 15-minute kWh data that can be downloaded in the event of lost communication with the RTU. The CSV data file can be quickly downloaded through a direct USB or Ethernet connection using ViewPoint HD software and can be used to backfill any missing data. This feature works automatically in the background to record data - no configuration necessary. In addition, the PowerScout HD Series has a capacitor-backed real-time clock (RTC) to ensure an accurate time stamp on all recorded data records. Unlike other systems, there is no battery to change and the capacitor retains calendar time for up to 1 week. The clock can be synchronized with the PC clock during meter setup.

Easy installation

Every PowerScout is line-powered and designed to operate on any voltage from 90 to 600 V AC. Configure the meter prior to installation using the ViewPoint HD software utility with a direct USB connection or via the built-in web server. Any combination of split-core or flexible RōCoil CTs can be used, however, for Legal Tenant Billing Applications in California, meters and CTs must receive CTEP approval. Patented PhaseChek™ technology ensures proper CT-to-phase installation the first time, eliminating costly return trips to the field.

Features

  • CTEP-approved for legal tenant billing applications in California
  • 24 channels: Multi-circuit submeter monitors voltage, current, power, energy, and many other electrical parameters on any combination of single and/or three-phase systems
  • Two independent voltage inputs allow the PowerScout HD meter to be used on two systems simultaneously
  • 90 to 600 V AC phase-to-phase power supply
  • Phase Loss Alarm can be set through software to be triggered by the voltage dropping below a set threshold
  • ANSI C12.20-2010 Class 0.2 revenue grade
  • Display shows real-time information about the meter configuration and metered data
  • High-voltage cover offers additional level of protection
  • Utilizes either BACnet or Modbus protocol over either serial or Ethernet
  • IEEE-754 data format allows for bidirectional monitoring and eliminates scaling factors
  • Mix-and-match a full range of CTEP-approved solid or split core CTs
  • PhaseChek™ ensures proper CT-to-phase installation the first time
  • CE Mark

Applications

  • Data Centers
  • Tenant Submetering
  • Bi-Directional Metering
  • Real-Time Power Monitoring in commercial, retail, and industrial environments

Dent PS24HD-C-D-N-C Specifications

Technical
Service Type Single phase, split phase, three phase-four wire (WYE), three phase-three wire (Delta)
Power From L1 Phase to L2 Phase. 90 to 600 V AC RMS CAT III 50/60 Hz, 500 mA AC Maximum. Use of 12-volt auxiliary output requires 100 V AC minimum input voltage
AC Protection 0.5 A fuse 200 kA interrupt capacity
Power Out Unregulated 12 V DC output, 200 mA, self-resetting fuse
Channels Voltage: 90 to 346 V AC line-to-neutral, 600 V line-to-line, CAT III. Two voltage reference inputs
Current: 24 channels, 0.525 V AC maximum, 333 mV CTs, 0 to 4000 A depending on CT
Maximum Current Input 150% of current transducer rating (mV CTs) to maintain accuracy. Measure up to 4000 A with RōCoil CTs
Measurement Type True RMS using high-speed digital signal processing (DSP) with continuous sampling
Line Frequency 50/60 Hz (45 to 70 Hz measurable range). Measurement taken L1-N.
Waveform Sampling 1.8 kHz
Parameter Update Rate 1 second
Measurements Volts, Amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, Import (Received) kWh, Export (Delivered) kWh, Net kWh, Import (Received) kVAh, Export (Delivered) kVAh, Net kVAh, Import (Received) kVARh, Export (Delivered) kVARh, Net kVARh, THD, Theta, Frequency. All parameters for each phase and element total
Accuracy 0.2% ANSI C12.20-2010 Class 0.2
Resolution Values in IEEE-754 single precision floating point format (32 bit)
Display 4-line display, tri-color backlight (PhaseChek™)
Alarm Output User-configurable Phase Loss Alarm
Pulse Inputs Two inputs. 3.3 V sourcing voltage (current limited) to customer dry contact pulse output. Maximum pulse rate 10 Hz (50 mSec minimum transition time)
Communication
Hardware RS-485, Ethernet, and USB (for configuration only)
Supported Protocols Modbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP
General Specifications
Mounting Enclosure
Enclosure Material: ABS Plastic, 94-V0 flammability rating. Connections: 1" EMT conduit
Dimensions 13.3 x 9.8 x 3.1" (33.7 x 25.1 x 8.0 cm)
Click here for complete specifications on the Dent PS24HD-C-D-N-C

What's included with the Dent PS24HD-C-D-N-C

  • Dent PS24HD-C-D-N-C PowerScout 24 HD Multi-Circuit Power Submeter, with enclosure, display, CTEP

Ask a question about Dent PS24HD-C-D-N-C PowerScout 24 HD Multi-Circuit Power Submeter, with enclosure, display, CTEP

Customer Reviews for the Dent PS24HD-C-D-N-C

Dent PS24HD-C-D-N-C Offers

Maximum flexibility for monitoring

The PowerScout 24 HD is a multi-circuit submeter that monitors a variety of electrical parameters on any combination of single and/or three-phase systems. With data updates every 1 second and ANSI C12.20-2010 Class 0.2 revenue-grade accuracy (depending on CT), the PowerScout 24 HD is well-suited for data center monitoring, tenant submetering, and accountability metering in commercial, retail, and industrial facilities

Industry-standard modbus or bacnet

The PowerScout 24 HD supports both Modbus and BACnet communications protocols which are field-selectable. Communication interfaces are available through standard serial RS-485 or Ethernet, using either Modbus, BACnet MS/TP, Modbus TCP, or BACnet IP protocols. PowerScout 24 HD meters are equipped with two independent dry-contact pulse inputs, allowing for monitoring of customer-derived voltage networks. Configure each of the input channels independently with customizable units of measure (i.e., gallons) within ViewPoint HD software.

Interval data recording and RTC

The PowerScout HD Series features interval data recording of kWh. The meter’s non-volatile memory stores up to 63 days of 15-minute kWh data that can be downloaded in the event of lost communication with the RTU. The CSV data file can be quickly downloaded through a direct USB or Ethernet connection using ViewPoint HD software and can be used to backfill any missing data. This feature works automatically in the background to record data - no configuration necessary. In addition, the PowerScout HD Series has a capacitor-backed real-time clock (RTC) to ensure an accurate time stamp on all recorded data records. Unlike other systems, there is no battery to change and the capacitor retains calendar time for up to 1 week. The clock can be synchronized with the PC clock during meter setup.

Easy installation

Every PowerScout is line-powered and designed to operate on any voltage from 90 to 600 V AC. Configure the meter prior to installation using the ViewPoint HD software utility with a direct USB connection or via the built-in web server. Any combination of split-core or flexible RōCoil CTs can be used, however, for Legal Tenant Billing Applications in California, meters and CTs must receive CTEP approval. Patented PhaseChek™ technology ensures proper CT-to-phase installation the first time, eliminating costly return trips to the field.

Features

  • CTEP-approved for legal tenant billing applications in California
  • 24 channels: Multi-circuit submeter monitors voltage, current, power, energy, and many other electrical parameters on any combination of single and/or three-phase systems
  • Two independent voltage inputs allow the PowerScout HD meter to be used on two systems simultaneously
  • 90 to 600 V AC phase-to-phase power supply
  • Phase Loss Alarm can be set through software to be triggered by the voltage dropping below a set threshold
  • ANSI C12.20-2010 Class 0.2 revenue grade
  • Display shows real-time information about the meter configuration and metered data
  • High-voltage cover offers additional level of protection
  • Utilizes either BACnet or Modbus protocol over either serial or Ethernet
  • IEEE-754 data format allows for bidirectional monitoring and eliminates scaling factors
  • Mix-and-match a full range of CTEP-approved solid or split core CTs
  • PhaseChek™ ensures proper CT-to-phase installation the first time
  • CE Mark

Applications

  • Data Centers
  • Tenant Submetering
  • Bi-Directional Metering
  • Real-Time Power Monitoring in commercial, retail, and industrial environments

Dent PS24HD-C-D-N-C Specifications

Technical
Service Type Single phase, split phase, three phase-four wire (WYE), three phase-three wire (Delta)
Power From L1 Phase to L2 Phase. 90 to 600 V AC RMS CAT III 50/60 Hz, 500 mA AC Maximum. Use of 12-volt auxiliary output requires 100 V AC minimum input voltage
AC Protection 0.5 A fuse 200 kA interrupt capacity
Power Out Unregulated 12 V DC output, 200 mA, self-resetting fuse
Channels Voltage: 90 to 346 V AC line-to-neutral, 600 V line-to-line, CAT III. Two voltage reference inputs
Current: 24 channels, 0.525 V AC maximum, 333 mV CTs, 0 to 4000 A depending on CT
Maximum Current Input 150% of current transducer rating (mV CTs) to maintain accuracy. Measure up to 4000 A with RōCoil CTs
Measurement Type True RMS using high-speed digital signal processing (DSP) with continuous sampling
Line Frequency 50/60 Hz (45 to 70 Hz measurable range). Measurement taken L1-N.
Waveform Sampling 1.8 kHz
Parameter Update Rate 1 second
Measurements Volts, Amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, Import (Received) kWh, Export (Delivered) kWh, Net kWh, Import (Received) kVAh, Export (Delivered) kVAh, Net kVAh, Import (Received) kVARh, Export (Delivered) kVARh, Net kVARh, THD, Theta, Frequency. All parameters for each phase and element total
Accuracy 0.2% ANSI C12.20-2010 Class 0.2
Resolution Values in IEEE-754 single precision floating point format (32 bit)
Display 4-line display, tri-color backlight (PhaseChek™)
Alarm Output User-configurable Phase Loss Alarm
Pulse Inputs Two inputs. 3.3 V sourcing voltage (current limited) to customer dry contact pulse output. Maximum pulse rate 10 Hz (50 mSec minimum transition time)
Communication
Hardware RS-485, Ethernet, and USB (for configuration only)
Supported Protocols Modbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP
General Specifications
Mounting Enclosure
Enclosure Material: ABS Plastic, 94-V0 flammability rating. Connections: 1" EMT conduit
Dimensions 13.3 x 9.8 x 3.1" (33.7 x 25.1 x 8.0 cm)
Click here for complete specifications on the Dent PS24HD-C-D-N-C

What's included with the Dent PS24HD-C-D-N-C

  • Dent PS24HD-C-D-N-C PowerScout 24 HD Multi-Circuit Power Submeter, with enclosure, display, CTEP

Ask a question about Dent PS24HD-C-D-N-C PowerScout 24 HD Multi-Circuit Power Submeter, with enclosure, display, CTEP

Customer Reviews for the Dent PS24HD-C-D-N-C

More Dent Products