Dent PowerScout PS3037-E-D Revenue Grade Networked Power Meter

Model: PS3037-E-D

Dent PowerScout PS3037-E-D Revenue Grade Networked Power Meter

Model: PS3037-E-D

Revenue-grade power meter with Ethernet and Serial Communications with onboard display. Capable of monitoring voltage, current, power, energy and other parameters.

Revenue-grade power meter with Ethernet and Serial Communications with onboard display. Capable of monitoring voltage, current, power, energy and other parameters.

Sale Price $595.35 USD
Regular Price $630.00 USD
Availability 1 to 2 Weeks
Quantity

Dent PowerScout PS3037 Series Offers

This power meter replaces the former PowerScout 3 plus model. Measurement capabilities include the ability to monitor voltage, current, power, energy and many other parameters.

Featuring a broadband power supply (80-600VAC) and the capability of being paired with a variety of current transformers, including split cores that measure < 1A and RoCoils designed for measuring 4000A. Additionally, communications protocols are field-selectable, allowing users to easily toggle between Modbus or BACnet.

The PowerScout is designed to provide timely and accurate consumption data to gain the upper hand on electrical costs in today's escalating energy market. PowerScout meters can capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring on three-phase or single-phase circuit installations. The PowerScout's flexibility, size, and ease-of-use make them ideal tools for gathering detailed consumption data in commercial, industrial, government and retail environments.

Quick & Easy Setup

Configuring the PS3037 for a new project is faster than ever thanks to the standard USB port. Configure by connecting the meter to a PC outfitted with the ViewPoint software. You'll be able to select a CT type, communication protocol and other parameters. Users with more than one meter will be able to easily share configurations between meters using the ViewPoint software.

Features

  • USB Port for Quick & Easy Setup: Simply connect the PS3037 to a PC, then use ViewPoint software to configure CT type, communication protocol, and other parameters.
  • Optional Display: The scrolling display can be used for quickly reading real-time values and performing diagnostics during setup. Without even connecting to a laptop, know that the meter is configured properly before leaving the job site.
  • Serial & Ethernet on the Same Unit. No longer be limited to choosing either Serial or Ethernet. All Ethernet units (PS3037-E-X) are equipped with both RS-485 and RJ-45 connections standard. Having both communication methods ensures maximum flexibility in the field.
  • DIN Rail Mounting: Compact enough to facilitate in-panel mounting. Use the angled mounting tabs to install flush on the side or back of the panel wall. Or, use the built-in DIN rail channel for quick and easy mounting near the circuit panel.
  • No Integral Voltage Leads: Voltage leads are now user-supplied. Because of this, there is no distinction between "US" and "INTERNATIONAL" PowerScout 3037 instruments. All configurations of the PS3037 can be used throughout the world (50/60Hz)
  • Revenue-Grade Performance: ANSI C12.20-2010 qualified Class 0.2
  • Over 50 measured parameters for energy measurement, monitoring and diagnostics. Monitors voltage, current, power, energy, and many other electrical parameters on single and three-phase systems.
  • Single or 3-phase energy and power meter for submetering applications
  • Choose from a full range of Split-Core or RoCoil Rogowski-style current transformers
  • Patented PhaseChek LED indicators ensure correct CT orientation during installation
  • Line-Powered
  • Equipped with industry-standard Modbus and BACnet Communications
  • Data updates occur every 0.5 second
  • ViewPointSetup Utility software: Verify meter installation, switch between communication protocols, and check real-time values before leaving the job site. ViewPoint 4.0 or later required for the PowerScout 3037.
  • UL & CE Mark
  • 5-Year Warranty

Applications

  • Tenant submetering
  • Net metering
  • Data center
  • Monitoring
  • Commercial
  • Retail
  • Industrial

Specifications

Technical
Service Type Single Phase
WYE: 3 Phase - 4 Wire
Delta: 3 Phase - 3 Wire
Power From L1 Phase to L2 Phase. 80 to 600VAC CAT III 50/60Hz,
70mA Max. Non-user replaceable .5 Amp internal fuse protection
Power Out Unregulated 5VDC output, 140 mA Max, resetting fuse
Voltage Channels AC Line-to-Neutral: 80 to 346V
Phase-to-Phase: 600V, CAT III
Current Channels 3 channels, 0.52 VAC max, 333 mV CTs, 0 to 4,000A
Maximum Current Input 158% of current transducer rating (mV CTs) to maintain accuracy.
Measure up to 4000A with RoCoil CTs
Measurement Type True RMS using high-speed digital signal processing (DSP)
Line Frequency 50/60 Hz
Measurements Volts, Amps, kW, kWh, kVAR, kVARh, kVA, kVAh, aPF, dPF
Accuracy 0.2% (<0.1% typical) ANSI C12.20-2010 Class 0.2
Communications
Direct User selectable Modbus/BACnet Master Slave Token Passing protocol (MS/TP)
or (optional) BACnet IP/Modbus TCP over Ethernet
Baud Rate 9600 (Modbus default), 19200, 38400, 57600, 76800 (BACnet default), 115200
Data Bits 8
Parity None, Even, Odd
Stop Bit 2, 1
Click here for complete specifications on the Dent PS3037-E-D

What's included with the Dent PS3037-E-D

  • Revenue Grade Networked Power Meter
  • Certificate of Calibration (COC)

How to Install the Dent PowerScout 3037 Revenue Grade Networked Power Meters


This video will walk professionals through each step to install the Dent PowerScout 3037 power meter. Feel at ease and confident installing this power meter with all of the suggested tools and supplies mentioned at the beginning of the video.

Click on a category to view a selection of compatible accessories with the Dent PowerScout PS3037-E-D Revenue Grade Networked Power Meter.

Dent CT-HSC-020-U Mini Hinged Current Transformer, 20A CT-HSC-020-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 20A amp rating.




Dent CT-HSC-050-U Mini Hinged Current Transformer, 50A CT-HSC-050-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 50A amp rating.




Dent CT-HMC-0100-U Midi Hinged Current Transformer, 100A CT-HMC-0100-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 100A amp rating.




Dent CT-HMC-0200-U Midi Hinged Current Transformer, 200A CT-HMC-0200-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 200A amp rating.




Dent CT-SCS-0050-U Small Split Core Current Transformer, 50A CT-SCS-0050-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 0.75Ó and offers a 50A amp rating.




Dent CT-SCM-0100-U Medium Split Core Current Transformer, 100A CT-SCM-0100-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 100A amp rating.




Dent CT-SCM-0200-U Medium Split Core Current Transformer, 200A CT-SCM-0200-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 200A amp rating.




Dent CT-SCM-0400-U Medium Split Core Current Transformer, 400A CT-SCM-0400-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 400A amp rating.




Dent CT-SCM-0600-U Medium Split Core Current Transformer, 600A CT-SCM-0600-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 600A amp rating.




Dent CT-SCL-1000-U Large Split Core Current Transformer, 1000A CT-SCL-1000-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 2.0" and offers a 1000A amp rating.




Customer Reviews for the Dent PS3037-E-D

Ask a question about Dent PowerScout PS3037-E-D Revenue Grade Networked Power Meter

Dent PowerScout PS3037 Series Offers

This power meter replaces the former PowerScout 3 plus model. Measurement capabilities include the ability to monitor voltage, current, power, energy and many other parameters.

Featuring a broadband power supply (80-600VAC) and the capability of being paired with a variety of current transformers, including split cores that measure < 1A and RoCoils designed for measuring 4000A. Additionally, communications protocols are field-selectable, allowing users to easily toggle between Modbus or BACnet.

The PowerScout is designed to provide timely and accurate consumption data to gain the upper hand on electrical costs in today's escalating energy market. PowerScout meters can capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring on three-phase or single-phase circuit installations. The PowerScout's flexibility, size, and ease-of-use make them ideal tools for gathering detailed consumption data in commercial, industrial, government and retail environments.

Quick & Easy Setup

Configuring the PS3037 for a new project is faster than ever thanks to the standard USB port. Configure by connecting the meter to a PC outfitted with the ViewPoint software. You'll be able to select a CT type, communication protocol and other parameters. Users with more than one meter will be able to easily share configurations between meters using the ViewPoint software.

Features

  • USB Port for Quick & Easy Setup: Simply connect the PS3037 to a PC, then use ViewPoint software to configure CT type, communication protocol, and other parameters.
  • Optional Display: The scrolling display can be used for quickly reading real-time values and performing diagnostics during setup. Without even connecting to a laptop, know that the meter is configured properly before leaving the job site.
  • Serial & Ethernet on the Same Unit. No longer be limited to choosing either Serial or Ethernet. All Ethernet units (PS3037-E-X) are equipped with both RS-485 and RJ-45 connections standard. Having both communication methods ensures maximum flexibility in the field.
  • DIN Rail Mounting: Compact enough to facilitate in-panel mounting. Use the angled mounting tabs to install flush on the side or back of the panel wall. Or, use the built-in DIN rail channel for quick and easy mounting near the circuit panel.
  • No Integral Voltage Leads: Voltage leads are now user-supplied. Because of this, there is no distinction between "US" and "INTERNATIONAL" PowerScout 3037 instruments. All configurations of the PS3037 can be used throughout the world (50/60Hz)
  • Revenue-Grade Performance: ANSI C12.20-2010 qualified Class 0.2
  • Over 50 measured parameters for energy measurement, monitoring and diagnostics. Monitors voltage, current, power, energy, and many other electrical parameters on single and three-phase systems.
  • Single or 3-phase energy and power meter for submetering applications
  • Choose from a full range of Split-Core or RoCoil Rogowski-style current transformers
  • Patented PhaseChek LED indicators ensure correct CT orientation during installation
  • Line-Powered
  • Equipped with industry-standard Modbus and BACnet Communications
  • Data updates occur every 0.5 second
  • ViewPointSetup Utility software: Verify meter installation, switch between communication protocols, and check real-time values before leaving the job site. ViewPoint 4.0 or later required for the PowerScout 3037.
  • UL & CE Mark
  • 5-Year Warranty

Applications

  • Tenant submetering
  • Net metering
  • Data center
  • Monitoring
  • Commercial
  • Retail
  • Industrial

Specifications

Technical
Service Type Single Phase
WYE: 3 Phase - 4 Wire
Delta: 3 Phase - 3 Wire
Power From L1 Phase to L2 Phase. 80 to 600VAC CAT III 50/60Hz,
70mA Max. Non-user replaceable .5 Amp internal fuse protection
Power Out Unregulated 5VDC output, 140 mA Max, resetting fuse
Voltage Channels AC Line-to-Neutral: 80 to 346V
Phase-to-Phase: 600V, CAT III
Current Channels 3 channels, 0.52 VAC max, 333 mV CTs, 0 to 4,000A
Maximum Current Input 158% of current transducer rating (mV CTs) to maintain accuracy.
Measure up to 4000A with RoCoil CTs
Measurement Type True RMS using high-speed digital signal processing (DSP)
Line Frequency 50/60 Hz
Measurements Volts, Amps, kW, kWh, kVAR, kVARh, kVA, kVAh, aPF, dPF
Accuracy 0.2% (<0.1% typical) ANSI C12.20-2010 Class 0.2
Communications
Direct User selectable Modbus/BACnet Master Slave Token Passing protocol (MS/TP)
or (optional) BACnet IP/Modbus TCP over Ethernet
Baud Rate 9600 (Modbus default), 19200, 38400, 57600, 76800 (BACnet default), 115200
Data Bits 8
Parity None, Even, Odd
Stop Bit 2, 1
Click here for complete specifications on the Dent PS3037-E-D

What's included with the Dent PS3037-E-D

  • Revenue Grade Networked Power Meter
  • Certificate of Calibration (COC)

How to Install the Dent PowerScout 3037 Revenue Grade Networked Power Meters


This video will walk professionals through each step to install the Dent PowerScout 3037 power meter. Feel at ease and confident installing this power meter with all of the suggested tools and supplies mentioned at the beginning of the video.

Click on a category to view a selection of compatible accessories with the Dent PowerScout PS3037-E-D Revenue Grade Networked Power Meter.

Dent CT-HSC-020-U Mini Hinged Current Transformer, 20A CT-HSC-020-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 20A amp rating.




Dent CT-HSC-050-U Mini Hinged Current Transformer, 50A CT-HSC-050-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 50A amp rating.




Dent CT-HMC-0100-U Midi Hinged Current Transformer, 100A CT-HMC-0100-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 100A amp rating.




Dent CT-HMC-0200-U Midi Hinged Current Transformer, 200A CT-HMC-0200-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 200A amp rating.




Dent CT-SCS-0050-U Small Split Core Current Transformer, 50A CT-SCS-0050-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 0.75Ó and offers a 50A amp rating.




Dent CT-SCM-0100-U Medium Split Core Current Transformer, 100A CT-SCM-0100-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 100A amp rating.




Dent CT-SCM-0200-U Medium Split Core Current Transformer, 200A CT-SCM-0200-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 200A amp rating.




Dent CT-SCM-0400-U Medium Split Core Current Transformer, 400A CT-SCM-0400-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 400A amp rating.




Dent CT-SCM-0600-U Medium Split Core Current Transformer, 600A CT-SCM-0600-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 600A amp rating.




Dent CT-SCL-1000-U Large Split Core Current Transformer, 1000A CT-SCL-1000-U