Image is for reference only, refer to product info for complete details.
This wireless pressure and temperature gauge is a compact, portable instrument for accurately measuring and calculating HVAC/R data, such as pressure, SuperHeat, SubCool and temperature differential.
This wireless pressure and temperature gauge is a compact, portable instrument for accurately measuring and calculating HVAC/R data, such as pressure, SuperHeat, SubCool and temperature differential.
Use the PT200W wireless pressure and temperature gauge as a stand-alone gauge or pair with a mobile device to set up, store or e-mail client and job lists, job site data, invoices and other convenient, time saving features.
Features
CPS Link™ app Features
Operating Pressure Range | -14.5 to 750 psig |
Pressure Reading Accuracy | 1% of reading ±0.1 psig (0.01 bar) |
Maximum Pressure | 750 psig mwp, 3000 psig burst |
Operating Temperature Range | 23 to 149°F (-5 to 65°C) |
Temperature Reading Accuracy | ±0.36°F (±0.2°C) |
SH, SC & Saturation Temperature Accuracy | ±0.5°F (±0.3°C) |
tH & tL Thermistor Temperature Range | -40 to 302°F (-40 to 150°C) |
Clamp | Opening: 1-1/8" (28.5 mm) Cord Length: 6 ft (1.82 m) |
Storage Temperature Range | -40 to 185°F (-40 to 85°C) |
Operating and Storage Humidity | 0 to 95%, non condensing |
Wireless Range | Power high: Up to 250 ft (76 m) Power normal: Up to 175 ft (53 m) Power low: Up to 100 ft (30 m) |
Power Source | 9 V alkaline battery (ANSI 1604 AC - IEC 6LR61) |
Battery Life | Up to 40 h continuous use |
Auto-Off | 10 mins |
Mechanical Connection | Standard 1/4" female SAE refrigerant hose type (stainless steel) with core depressor |
Gauge to Wireless Device Connection | Patented wireless CPS Link™ technology (US Patent No. 9,043,161) |
Operating Pressure Range | -14.5 to 750 psig |
Pressure Reading Accuracy | 1% of reading ±0.1 psig (0.01 bar) |
Maximum Pressure | 750 psig mwp, 3000 psig burst |
Operating Temperature Range | 23 to 149°F (-5 to 65°C) |
Temperature Reading Accuracy | ±0.36°F (±0.2°C) |
SH, SC & Saturation Temperature Accuracy | ±0.5°F (±0.3°C) |
tH & tL Thermistor Temperature Range | -40 to 302°F (-40 to 150°C) |
Clamp | Opening: 1-1/8" (28.5 mm) Cord Length: 6 ft (1.82 m) |
Storage Temperature Range | -40 to 185°F (-40 to 85°C) |
Operating and Storage Humidity | 0 to 95%, non condensing |
Wireless Range | Power high: Up to 250 ft (76 m) Power normal: Up to 175 ft (53 m) Power low: Up to 100 ft (30 m) |
Power Source | 9 V alkaline battery (ANSI 1604 AC - IEC 6LR61) |
Battery Life | Up to 40 h continuous use |
Auto-Off | 10 mins |
Mechanical Connection | Standard 1/4" female SAE refrigerant hose type (stainless steel) with core depressor |
Gauge to Wireless Device Connection | Patented wireless CPS Link™ technology (US Patent No. 9,043,161) |