The photo-ionization sensor detects volatile organic compounds or VOCs and can be added to a standard four gas configuration or combined with non-standard combinations of other sensors. Offers maximum versatility in a portable multi-gas detector that can be used almost anywhere. Five gases can be monitored and displayed at the same time. Lock your instruments settings allowing only authenticated personnel to change your settings. Yellow housing.
The photo-ionization sensor detects volatile organic compounds or VOCs and can be added to a standard four gas configuration or combined with non-standard combinations of other sensors. Offers maximum versatility in a portable multi-gas detector that can be used almost anywhere. Five gases can be monitored and displayed at the same time. Lock your instruments settings allowing only authenticated personnel to change your settings. Yellow housing.
Discontinued!
This product has been discontinued and is no longer available.
There is no direct replacement, however we recommend the:
Not what you're looking for? Let’s do a search and help you find what you need.
| Gas | Measuring range | Resolution | TWA | STEL | LOW | HIGH |
| PID (VOCs) | 0-1000 ppm | 1 ppm | 50 | 100 | 50 | 100 |
| O2 | 0-30.0% | 0.1 | N/A | N/A | 19.5 | 22.5 |
| CO | 0-999 ppm | 1 | 35 | 200 | 35 | 200 |
| H2S | 0-100 ppm | 1 | 10 | 15 | 10 | 15 |
| NH3 | 0-100 ppm | 1 | 25 | 35 | 25 | 50 |
| LEL | 0-100% LEL 0-5% v/v | 1% | N/A | N/A | 10% | 20% |
| General Specifications | ||||
| Size | 5.7 x 2.9 x 1.5 in. / 14.5 x 7.4 x 3.8 cm | |||
| Weight | 13.1 oz. / 370 g | |||
| Temperature | -4 to +122°F / -20 to +50°C 14 to +104°F / -10 to +40°C (PID) | |||
| Alarms | Visual, vibrating, audible (95 dB) Low, High, STEL, TWA, OL (over limit) | |||
| Tests | Sensor integrity, circuitry, battery and audible/visual alarms on activation, battery (continuous) | |||
| Pump | Optional; Sample from up to 66 ft. / 20 m | |||
| Ratings | EMI/RFI: Complies with EMC Directive 89/336/EEC IP 65/66 | |||
| Substance | Ionization Energy | Detectable by | |||
| carbon monoxide | 14.01 | electrochemical sensor | |||
| hydrogen cyanide | 13.6 | electrochemical sensor | |||
| methane | 12.98 | combustible sensor | |||
| sulfur dioxide | 12.32 | electrochemical sensor | |||
| oxygen | 12.08 | O2 sensor | |||
| chlorine | 11.48 | electrochemical sensor | |||
| chlorine dioxide | 10.57 | electrochemical sensor | |||
| hydrogen sulfide | 10.46 | electrochemical sensor | |||
| n-hexane | 10.18 | electrochemical sensor | |||
| ammonia | 10.16 | electrochemical sensor | |||
| phosphine | 9.87 | electrochemical sensor | |||
| nitrogen dioxide | 9.75 | electrochemical sensor | |||
| acetone | 9.69 | — | |||
| MEK | 9.51 | — | |||
| butadiene | 9.07 | — | |||
| toluene | 8.82 | — | |||
Click on a category to view a selection of compatible accessories with the BW M5PID-XWQ0-A-P-D-Y-N-00 GasAlertMicro 5 PID Multi-Gas Detector, VOCs, %LEL, O2, Alkaline Batteries & Pump.