The 8526-220V can be used for testing and evaluating a variety of DC power sources. The loads can operate in CC, CV, CR or CP mode.

The 8526-220V can be used for testing and evaluating a variety of DC power sources. The loads can operate in CC, CV, CR or CP mode.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Chargers and Power Adapters category for similar products.

Or let's do a search and help you find what you need:


B&K 8526-220V Offers

These loads can operate in CC, CV, CR or CP mode while voltage/current or resistance/power values are measured and displayed in real time. Load terminals are isolated and floating. Over temperature, over power, over voltage, over current and reverse polarity protection will help protect your valuable prototype and circuits.

Features

  • Constant current (CC), resistance (CR), voltage (CV) and power (CP) operation
  • 8500 Series contains models with wide voltage and current range, 0 to 500 V, 0 to 240 A (5000 W max)
  • Built-in transient generator
  • Short circuit test
  • Over-Current/Over-Voltage/Over-Power/Over-Temperature Protection
  • USB to TTL serial converter cables and application software included
  • List mode operation for increased throughput
  • Battery testing mode to provide A*hr rating of battery (ending voltage level is adjustable)
  • Flexible triggering: Create trigger events by front panel keystroke, back panel TTL signal, or software.
  • Remote voltage sensing to compensate for the effect of voltage drop in wires

Applications

  • Batteries
  • Fuel Cells
  • Solar Cells
  • Evaluating and Testing DC Power Sources

B&K 8526-220V Specifications

Input Voltage 0 – 500 V
Input Current 0 – 120 A
Input Power 5000 W
Current Measurement 0 – 12 A
Voltage Measurement 0 – 18 V
Battery Testing Functiion Input = 0.1 V – 120 V, Max measurement capacity = 999 Ah, Resolution = 10 mA, Timer range = 1-60000 sec
Transition Mode Range of Frequency 0.1 Hz-1 kHz, Frequency error rate
AC Input 220V
Safety EN61010-1:2001, EU Low Voltage Directive 73/23/EEC amended by 93/68/EEC
Click here for complete specifications on the B&K 8526-220V

What's included with the B&K 8526-220V

  • B&K Precision 8526-220V DC Electronic Load
  • Power Cord
  • Installation CD with Application Software
  • Instruction Manual
  • USB to TTL Serial Converter IT-E132B
  • Certificate of Calibration and Test Report

Ask a question about B&K Precision 8526-220V DC Electronic Load, Programmable, 5000W, 120A, 220V

Customer Reviews for the B&K 8526-220V

B&K 8526-220V Offers

These loads can operate in CC, CV, CR or CP mode while voltage/current or resistance/power values are measured and displayed in real time. Load terminals are isolated and floating. Over temperature, over power, over voltage, over current and reverse polarity protection will help protect your valuable prototype and circuits.

Features

  • Constant current (CC), resistance (CR), voltage (CV) and power (CP) operation
  • 8500 Series contains models with wide voltage and current range, 0 to 500 V, 0 to 240 A (5000 W max)
  • Built-in transient generator
  • Short circuit test
  • Over-Current/Over-Voltage/Over-Power/Over-Temperature Protection
  • USB to TTL serial converter cables and application software included
  • List mode operation for increased throughput
  • Battery testing mode to provide A*hr rating of battery (ending voltage level is adjustable)
  • Flexible triggering: Create trigger events by front panel keystroke, back panel TTL signal, or software.
  • Remote voltage sensing to compensate for the effect of voltage drop in wires

Applications

  • Batteries
  • Fuel Cells
  • Solar Cells
  • Evaluating and Testing DC Power Sources

B&K 8526-220V Specifications

Input Voltage 0 – 500 V
Input Current 0 – 120 A
Input Power 5000 W
Current Measurement 0 – 12 A
Voltage Measurement 0 – 18 V
Battery Testing Functiion Input = 0.1 V – 120 V, Max measurement capacity = 999 Ah, Resolution = 10 mA, Timer range = 1-60000 sec
Transition Mode Range of Frequency 0.1 Hz-1 kHz, Frequency error rate
AC Input 220V
Safety EN61010-1:2001, EU Low Voltage Directive 73/23/EEC amended by 93/68/EEC
Click here for complete specifications on the B&K 8526-220V

What's included with the B&K 8526-220V

  • B&K Precision 8526-220V DC Electronic Load
  • Power Cord
  • Installation CD with Application Software
  • Instruction Manual
  • USB to TTL Serial Converter IT-E132B
  • Certificate of Calibration and Test Report

Ask a question about B&K Precision 8526-220V DC Electronic Load, Programmable, 5000W, 120A, 220V