| Voltage Adjustment Range | 0 to 150 V AC with input at 120 V AC |
| Output Isolation | Leakage less than 0.1 mA (25°C, 50% RH) |
| Current Range | 0 to 3 A |
| Maximum Current (Isolated) | 3 A continuous, 4 A intermittent (0 to 130 V) |
| Peak Current (Inrush) | 30 A maximum (inrush limited to one cycle at 30 A) |
| Voltage/Current Sensing | Sine wave average, calibrated in RMS |
| Meter Scale | 0 to 240 V AC 0 to 480 V AC (voltage set at 120) |
| Leakage | 0 to 5000 μA (expanded in 100 to 500 μA portion, compressed to 5 mA full scale) |
| Metering | 4½ multicolor scales, overrange protected |
| Typical Meter Accuracy | ±5% of full scale (volts and current) ±5% at 500 μA (leakage) |
| Soldering Iron Temperature Control | 70 to 99% of power line (100 W maximum) |
| AC Input | 120 V AC ±10%, 60 Hz |
| Dimensions | 10.5 x 5.7 x 12" (267 x 145 x 305 mm) |
| Weight | 22 lbs (10 kg) |
| Voltage Adjustment Range | 0 to 150 V AC with input at 120 V AC |
| Output Isolation | Leakage less than 0.1 mA (25°C, 50% RH) |
| Current Range | 0 to 3 A |
| Maximum Current (Isolated) | 3 A continuous, 4 A intermittent (0 to 130 V) |
| Peak Current (Inrush) | 30 A maximum (inrush limited to one cycle at 30 A) |
| Voltage/Current Sensing | Sine wave average, calibrated in RMS |
| Meter Scale | 0 to 240 V AC 0 to 480 V AC (voltage set at 120) |
| Leakage | 0 to 5000 μA (expanded in 100 to 500 μA portion, compressed to 5 mA full scale) |
| Metering | 4½ multicolor scales, overrange protected |
| Typical Meter Accuracy | ±5% of full scale (volts and current) ±5% at 500 μA (leakage) |
| Soldering Iron Temperature Control | 70 to 99% of power line (100 W maximum) |
| AC Input | 120 V AC ±10%, 60 Hz |
| Dimensions | 10.5 x 5.7 x 12" (267 x 145 x 305 mm) |
| Weight | 22 lbs (10 kg) |