We Ship Free on Orders Over $99 within the Continental United States

Customer Rating: 4.7/5 Stars

AEMC 6416 Clamp-On Ground Resistance Tester, 1500Ω

Model: 6416 | Order No: 2141.01 | UPC: 685338130485

AEMC 6416 Clamp-On Ground Resistance Tester, 1500Ω

Model: 6416 | Order No: 2141.01 | UPC: 685338130485

Employs stakeless ground loop testing and non-intrusive leakage current measurement, making it ideal for system troubleshooting in commercial, industrial, and utility applications. The 6416 can to take measurements without disconnecting or de-energizing the ground system under test and incorporates visible and audible alarms for dangerous voltage and current levels. Compact and rugged, the 6416 is easy to use in small places and harsh environments.

Employs stakeless ground loop testing and non-intrusive leakage current measurement, making it ideal for system troubleshooting in commercial, industrial, and utility applications. The 6416 can to take measurements without disconnecting or de-energizing the ground system under test and incorporates visible and audible alarms for dangerous voltage and current levels. Compact and rugged, the 6416 is easy to use in small places and harsh environments.

Sale Price $1320.50 USD
Regular Price $1390.00 USD
Availability 1 to 2 Weeks
Quantity

Add In-House Traceable Calibration to your 2141.01

Add In-House Traceable Calibration to your 2141.01


Recommended Accessories


AEMC 6416 Offers

The AEMC Model 6416 Ground Resistance Clamp Meter measures ground rod and grid resistance and impedance without the use of auxiliary rods. With the stakeless testing method, earth ground stakes are no longer necessary. The 6416 Earth Ground Clamp is placed around the earth ground rod or the connecting cable and a known voltage is induced by one half of the clamp while the current is measured by the other half. The tester automatically determines the ground loop resistance at this grounding connection.

The Stakeless testing method eliminates the need to disconnect parallel ground rods and find suitable locations for placing auxiliary ground stakes. This saves time and enables users such as industrial and utility electricians, and field service electricians and contractors, to perform earth ground loop tests in locations where it is not possible to use other techniques, including inside buildings or on power pylons.

A new contact voltage indication feature that warns when the voltage derived from current and resistance measurements detect a potentially dangerous touch condition, as well as selectable test frequency function that provides more accurate results in inductive environments, have been incorporated into the 6416 in order to improve its versatility and security.

Features

  • High sensitivity measurement function of leakage current flowing to ground or circulating in ground loops from 0.2mA to 40A
  • Resistance measurement from 0.01 to 1500Ω
  • Contact voltage indication warns of unsafe conditions
  • Selectable test frequency improves accuracy in inductive environments
  • Noise icon and buzzer alert user to presence of dangerous voltage and current levels
  • Multi-function bright yellow organic display (OLED)
  • Data storage function with time-stamping (up to 2000 measurements stored)
  • Battery life information at power-up and auto power off function
  • Large jaw opening of 35mm
  • Rugged Lexan® head and body construction resists breakage
  • Designed to EN61010-1, 600V Cat. IV safety standards
  • Includes hard carrying case, calibration loop, batteries, USB stick and user manual

Applications

  • Ground electrode system resistance
  • Bonding/continuity checks
  • Cell tower grounding verification
  • Ground measurements on Railroad signalling systems

AEMC 6416 Specifications

Ground Resistance
Range 0.010 to 0.099Ω 0.10 to 0.99Ω 1.0 to 49.9Ω 50.0 to 99.5Ω 100 to 199Ω 200 to 395Ω 400 to 590Ω 600 to 1150Ω 1200 to 1500Ω
Resolution 0.001Ω 0.01Ω 0.1Ω 0.5Ω 10Ω 50Ω 50Ω
Accuracy (% of Reading) ±1.5% ±0.01Ω ±1.5% ±0.01Ω ±1.5% ±0.1Ω ±2% ±0.5Ω ±3% ±1Ω ±5% ±5Ω ±10% ±10Ω 20% approx 25% approx
Auto-Ranging 1mA to 40A
Range 0.200 to 0.99mA 1.000 to 2.990mA< 3.00 to 9.99mA 10.00 to 29.90mA 30.0 to 99.9mA 100.0 to 299.0mA 0.300 to 0.990A 1.000 to 2.990A 3.00 to 39.99A
Resolution 1µA 10µA 10µA 100µA 100µA 1mA 1mA 10mA 10mA
Accuracy (% of Reading) ±2% ±50µA ±2% ±50µA ±2% ±50µA ±2% ±100µA ±2% ±100µA ±2% ±1mA ±2% ±1mA ±2% ±10mA ±2% ±10mA
Current Measurement
Range 0.200 to 0.999mA
Resolution 1µA
Accuracy (% of Reading) ±2% ±50µA
Click here for complete specifications on the AEMC 6416

What's included with the AEMC 6416

  • Clamp-On ground resistance tester
  • Hard carrying case
  • Calibration loop
  • 4 x 1.5V AA batteries

Click on a category to view a selection of compatible accessories with the AEMC 6416 Clamp-On Ground Resistance Tester, 1500&Omega.

-
AEMC 2141.51 Calibration Field Test Loop, 5Ω 2141.51
For use with the AEMC 3710-3731, 6416 & 6417 (Clamp-on).




Review the AEMC Instruments 6416

" data-description="Employs stakeless ground loop testing and non-intrusive leakage current measurement, making it ideal for system troubleshooting in commercial, industrial, and utility applications. The 6416 can to take measurements without disconnecting or de-energizing the ground system under test and incorporates visible and audible alarms for dangerous voltage and current levels. Compact and rugged, the 6416 is easy to use in small places and harsh environments.">

Ask a question about AEMC 6416 Clamp-On Ground Resistance Tester, 1500&Omega

AEMC 6416 Offers

The AEMC Model 6416 Ground Resistance Clamp Meter measures ground rod and grid resistance and impedance without the use of auxiliary rods. With the stakeless testing method, earth ground stakes are no longer necessary. The 6416 Earth Ground Clamp is placed around the earth ground rod or the connecting cable and a known voltage is induced by one half of the clamp while the current is measured by the other half. The tester automatically determines the ground loop resistance at this grounding connection.

The Stakeless testing method eliminates the need to disconnect parallel ground rods and find suitable locations for placing auxiliary ground stakes. This saves time and enables users such as industrial and utility electricians, and field service electricians and contractors, to perform earth ground loop tests in locations where it is not possible to use other techniques, including inside buildings or on power pylons.

A new contact voltage indication feature that warns when the voltage derived from current and resistance measurements detect a potentially dangerous touch condition, as well as selectable test frequency function that provides more accurate results in inductive environments, have been incorporated into the 6416 in order to improve its versatility and security.

Features

  • High sensitivity measurement function of leakage current flowing to ground or circulating in ground loops from 0.2mA to 40A
  • Resistance measurement from 0.01 to 1500Ω
  • Contact voltage indication warns of unsafe conditions
  • Selectable test frequency improves accuracy in inductive environments
  • Noise icon and buzzer alert user to presence of dangerous voltage and current levels
  • Multi-function bright yellow organic display (OLED)
  • Data storage function with time-stamping (up to 2000 measurements stored)
  • Battery life information at power-up and auto power off function
  • Large jaw opening of 35mm
  • Rugged Lexan® head and body construction resists breakage
  • Designed to EN61010-1, 600V Cat. IV safety standards
  • Includes hard carrying case, calibration loop, batteries, USB stick and user manual

Applications

  • Ground electrode system resistance
  • Bonding/continuity checks
  • Cell tower grounding verification
  • Ground measurements on Railroad signalling systems

AEMC 6416 Specifications

Ground Resistance
Range 0.010 to 0.099Ω 0.10 to 0.99Ω 1.0 to 49.9Ω 50.0 to 99.5Ω 100 to 199Ω 200 to 395Ω 400 to 590Ω 600 to 1150Ω 1200 to 1500Ω
Resolution 0.001Ω 0.01Ω 0.1Ω 0.5Ω 10Ω 50Ω 50Ω
Accuracy (% of Reading) ±1.5% ±0.01Ω ±1.5% ±0.01Ω ±1.5% ±0.1Ω ±2% ±0.5Ω ±3% ±1Ω ±5% ±5Ω ±10% ±10Ω 20% approx 25% approx
Auto-Ranging 1mA to 40A
Range 0.200 to 0.99mA 1.000 to 2.990mA< 3.00 to 9.99mA 10.00 to 29.90mA 30.0 to 99.9mA 100.0 to 299.0mA 0.300 to 0.990A 1.000 to 2.990A 3.00 to 39.99A
Resolution 1µA 10µA 10µA 100µA 100µA 1mA 1mA 10mA 10mA
Accuracy (% of Reading) ±2% ±50µA ±2% ±50µA ±2% ±50µA ±2% ±100µA ±2% ±100µA ±2% ±1mA ±2% ±1mA ±2% ±10mA ±2% ±10mA
Current Measurement
Range 0.200 to 0.999mA
Resolution 1µA
Accuracy (% of Reading) ±2% ±50µA
Click here for complete specifications on the AEMC 6416

What's included with the AEMC 6416

  • Clamp-On ground resistance tester
  • Hard carrying case
  • Calibration loop
  • 4 x 1.5V AA batteries

Click on a category to view a selection of compatible accessories with the AEMC 6416 Clamp-On Ground Resistance Tester, 1500&Omega.

-
AEMC 2141.51 Calibration Field Test Loop, 5Ω 2141.51
For use with the AEMC 3710-3731, 6416 & 6417 (Clamp-on).




Ask a question about AEMC 6416 Clamp-On Ground Resistance Tester, 1500&Omega

Review the AEMC Instruments 6416

" data-description="Employs stakeless ground loop testing and non-intrusive leakage current measurement, making it ideal for system troubleshooting in commercial, industrial, and utility applications. The 6416 can to take measurements without disconnecting or de-energizing the ground system under test and incorporates visible and audible alarms for dangerous voltage and current levels. Compact and rugged, the 6416 is easy to use in small places and harsh environments.">

More AEMC Products

Calibration Lab