This Current Probe is designed for use in utility and industrial environments. The unique ergonomic design allows it to easily clamp onto cables or small bus bars. It is assembled to the highest safety and performance standards including the CE Mark and is UL approved for Canada and United States.

This Current Probe is designed for use in utility and industrial environments. The unique ergonomic design allows it to easily clamp onto cables or small bus bars. It is assembled to the highest safety and performance standards including the CE Mark and is UL approved for Canada and United States.

Sale Price $279.30 USD
Regular Price $294.00 USD
Availability 4 to 5 Weeks
Quantity

Add In-House Traceable Calibration to your SR634

Add In-House Traceable Calibration to your SR634


AEMC SR634 Offers

This a general purpose 1000AAC current probe designed for use with instruments that require a 5A current input. It works as a traditional current transformer (with ratios of 250:5, 500:5 or 1000:5) and has an output of 5mA per amp measured in the jaw. The SR634 has jack output termination that accept 4mm banana plugs. The rounded jaw design on this probe makes it well-suited for power applications where high accuracy and low phase shift is important.

Features

  • Measurement range of 100mA to 1200AAC
  • Large jaw opening accommodates conductors up to two 500kcmil
  • Improved ergonomic design and easy operation
  • Conforms to EN 61010, 600V CAT III
  • Low phase shift for power measurement
  • Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters

Applications

  • Power quality measuring
  • Large industrial loads
  • Measuring around cable bundles
  • Power load monitoring
  • Waveform analysis

AEMC SR634 Specifications

Nominal Range 250, 500, 1000A
Measurement Range 0.1 to 1200A
Transformation Ratio 250:5, 500:5, 1000:5
Output Signal 5mA, 10mA, 20mA AC/A AC (5A AC at 250, 500 or 1000A)
Accuracy (250A Range) 1 to 5A: ≤10% ± 0.1A
5A: 10% of Reading
12.5A: 5% of Reading
50A: 2.5% of Reading
250A: 2% of Reading
300A: 2% of Reading
Phase Shift (250A Range) 12.5A: 10°
50A: 10°
250A: 10°
300A: 10°
Accuracy (500A Range) 1 to 10A: ≤6% ± 0.1A
10A: 6% of Reading
25A: 3% of Reading
100A: 2% of Reading
500A: 1% of Reading
600A: 1% of Reading
Phase Shift (500A Range) 10A: 6°
25A: 4°
100A: 3°
500A: 2.5°
600A: 2.5°
Accuracy (1000A Range) 1 to 20A: ≤6% ± 0.1A
20A: 5% of Reading
50A: 3% of Reading
200A: 1.5% of Reading
1000A: 1% of Reading
1200A: 1% of Reading
Phase Shift (1000A Range) 20A: 5°
50A: 3°
200A: 1.5°
1000A: 1°
1200A: 1°
Overload 1200A for 30 min ON, 15 min OFF
Frequency Range 30Hz to 5kHz
Current derating above 1kHz using the formula: 1000A x 1/F (in kHz)
Load Impedance 0.4Ω max
Working/Common Mode Voltage 600V Cat. III
Output Termination Jack
Click here for complete specifications on the AEMC SR634

What's included with the AEMC SR634

  • AEMC SR634 AC Current Probe, 250, 500, 1200A AC
  • Customer Reviews for the AEMC SR634

    Ask a question about AEMC SR634 AC Current Probe, 250, 500, 1200A AC

    AEMC SR634 Offers

    This a general purpose 1000AAC current probe designed for use with instruments that require a 5A current input. It works as a traditional current transformer (with ratios of 250:5, 500:5 or 1000:5) and has an output of 5mA per amp measured in the jaw. The SR634 has jack output termination that accept 4mm banana plugs. The rounded jaw design on this probe makes it well-suited for power applications where high accuracy and low phase shift is important.

    Features

    • Measurement range of 100mA to 1200AAC
    • Large jaw opening accommodates conductors up to two 500kcmil
    • Improved ergonomic design and easy operation
    • Conforms to EN 61010, 600V CAT III
    • Low phase shift for power measurement
    • Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters

    Applications

    • Power quality measuring
    • Large industrial loads
    • Measuring around cable bundles
    • Power load monitoring
    • Waveform analysis

    AEMC SR634 Specifications

    Nominal Range 250, 500, 1000A
    Measurement Range 0.1 to 1200A
    Transformation Ratio 250:5, 500:5, 1000:5
    Output Signal 5mA, 10mA, 20mA AC/A AC (5A AC at 250, 500 or 1000A)
    Accuracy (250A Range) 1 to 5A: ≤10% ± 0.1A
    5A: 10% of Reading
    12.5A: 5% of Reading
    50A: 2.5% of Reading
    250A: 2% of Reading
    300A: 2% of Reading
    Phase Shift (250A Range) 12.5A: 10°
    50A: 10°
    250A: 10°
    300A: 10°
    Accuracy (500A Range) 1 to 10A: ≤6% ± 0.1A
    10A: 6% of Reading
    25A: 3% of Reading
    100A: 2% of Reading
    500A: 1% of Reading
    600A: 1% of Reading
    Phase Shift (500A Range) 10A: 6°
    25A: 4°
    100A: 3°
    500A: 2.5°
    600A: 2.5°
    Accuracy (1000A Range) 1 to 20A: ≤6% ± 0.1A
    20A: 5% of Reading
    50A: 3% of Reading
    200A: 1.5% of Reading
    1000A: 1% of Reading
    1200A: 1% of Reading
    Phase Shift (1000A Range) 20A: 5°
    50A: 3°
    200A: 1.5°
    1000A: 1°
    1200A: 1°
    Overload 1200A for 30 min ON, 15 min OFF
    Frequency Range 30Hz to 5kHz
    Current derating above 1kHz using the formula: 1000A x 1/F (in kHz)
    Load Impedance 0.4Ω max
    Working/Common Mode Voltage 600V Cat. III
    Output Termination Jack
    Click here for complete specifications on the AEMC SR634