AEMC SR604 AC Current Probe, Lead, 1mA/A, 1200A AC

Model: SR604 | Order No: 2113.44 | UPC: 685338040036

AEMC SR604 AC Current Probe, Lead, 1mA/A, 1200A AC

Model: SR604 | Order No: 2113.44 | UPC: 685338040036

This Current Probe is designed for use with DMMs, loggers and other instruments that have a current input in utility and industrial environments. The unique ergonomic design allows it to easily clamp onto cables or small bus bars. It is assembled to the highest safety and performance standards including the CE Mark and is UL approved for Canada and United States.

This Current Probe is designed for use with DMMs, loggers and other instruments that have a current input in utility and industrial environments. The unique ergonomic design allows it to easily clamp onto cables or small bus bars. It is assembled to the highest safety and performance standards including the CE Mark and is UL approved for Canada and United States.

Sale Price $202.35 USD
Regular Price $213.00 USD
Availability 1 Week
Quantity

Add In-House Traceable Calibration to your SR604

Add In-House Traceable Calibration to your SR604


AEMC SR604 Offers

This general purpose 1000AAC current probe has a 1000:1 ratio and output of 1mA per amp measured in the jaw. The probe has an integral 5 ft (1.5m) lead terminated shrouded banana plugs. The rounded jaw design on this probe makes it well-suited for power applications where high accuracy and low phase shift is important. The SR604 works as a traditional current transformer (with a ratio of 1000:1) and provides current outputs in mA/A for use on DMMs, power and harmonic meters, data loggers, recorders or instruments with current ranges.

Features

  • Measurement range of 100mA to 1200AAC
  • Large jaw opening accommodates conductors up to two 500kcmil
  • Improved ergonomic design and easy operation
  • Conforms to EN 61010, 600V Cat. III
  • Low phase shift for power measurement
  • Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters

Applications

  • Power quality measuring
  • Large industrial loads
  • Measuring around cable bundles
  • Power load monitoring
  • Waveform analysis

AEMC SR604 Specifications

Nominal Range 1000A
Measurement Range 0.1 to 1200A
Transformation Ratio 1000:1
Output Signal 1mA AC/A AC: (1A AC at 1000A)
Accuracy (1000A Range) 0.1 to 10A: ≤3% + 0.1A
50A: 1.5% of Reading; 200A: 0.75% of Reading
1000A: 0.5% of Reading
1200A: 0.5% of Reading
Phase Shift (1000A Range) 50A: 1.5°
200A: 0.75°
1000A: 0.5°
1200A: 0.5°
Overload 1200A for 40 min ON, 20 min OFF
Frequency Range 30Hz to 5kHz
Current derating above 1kHz using the formula: 1000A x 1/F (in kHz)
Load Impedance 5Ω max
Working/Common Mode Voltage 600V Cat. III
Output Termination Lead
Click here for complete specifications on the AEMC SR604

What's included with the AEMC SR604

  • AEMC SR604 AC Current Probe, Lead, 1mA/A, 1200A AC
  • Customer Reviews for the AEMC SR604

    Ask a question about AEMC SR604 AC Current Probe, Lead, 1mA/A, 1200A AC

    AEMC SR604 Offers

    This general purpose 1000AAC current probe has a 1000:1 ratio and output of 1mA per amp measured in the jaw. The probe has an integral 5 ft (1.5m) lead terminated shrouded banana plugs. The rounded jaw design on this probe makes it well-suited for power applications where high accuracy and low phase shift is important. The SR604 works as a traditional current transformer (with a ratio of 1000:1) and provides current outputs in mA/A for use on DMMs, power and harmonic meters, data loggers, recorders or instruments with current ranges.

    Features

    • Measurement range of 100mA to 1200AAC
    • Large jaw opening accommodates conductors up to two 500kcmil
    • Improved ergonomic design and easy operation
    • Conforms to EN 61010, 600V Cat. III
    • Low phase shift for power measurement
    • Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters

    Applications

    • Power quality measuring
    • Large industrial loads
    • Measuring around cable bundles
    • Power load monitoring
    • Waveform analysis

    AEMC SR604 Specifications

    Nominal Range 1000A
    Measurement Range 0.1 to 1200A
    Transformation Ratio 1000:1
    Output Signal 1mA AC/A AC: (1A AC at 1000A)
    Accuracy (1000A Range) 0.1 to 10A: ≤3% + 0.1A
    50A: 1.5% of Reading; 200A: 0.75% of Reading
    1000A: 0.5% of Reading
    1200A: 0.5% of Reading
    Phase Shift (1000A Range) 50A: 1.5°
    200A: 0.75°
    1000A: 0.5°
    1200A: 0.5°
    Overload 1200A for 40 min ON, 20 min OFF
    Frequency Range 30Hz to 5kHz
    Current derating above 1kHz using the formula: 1000A x 1/F (in kHz)
    Load Impedance 5Ω max
    Working/Common Mode Voltage 600V Cat. III
    Output Termination Lead
    Click here for complete specifications on the AEMC SR604

    What's included with the AEMC SR604

  • AEMC SR604 AC Current Probe, Lead, 1mA/A, 1200A AC
  • Ask a question about AEMC SR604 AC Current Probe, Lead, 1mA/A, 1200A AC

    Customer Reviews for the AEMC SR604

    More AEMC Products

    Calibration Lab