AEMC MN82 AC Current Probe for the 6471 and 6472, 40A

Model: MN82 | Order No: 2135.71 | UPC: 685338139860

AEMC MN82 AC Current Probe for the 6471 and 6472, 40A

Model: MN82 | Order No: 2135.71 | UPC: 685338139860

Designed specifically for use with the AEMC 6471 and 6472 Ground Resistance Tester. When a single probe is used in conjunction with the traditional fall-all-potential method, selective grounds can be measured by moving the probe from point to point around the grounding system.

Designed specifically for use with the AEMC 6471 and 6472 Ground Resistance Tester. When a single probe is used in conjunction with the traditional fall-all-potential method, selective grounds can be measured by moving the probe from point to point around the grounding system.

Sale Price $288.80 USD
Regular Price $304.00 USD
Availability 2 to 3 Weeks
Quantity

Recommended Accessories


AEMC MN82 Offers

When two MN82 probes are used in conjunction with the AEMC 6471 and 6472, grounding electrodes can be measured without the necessity of installing auxiliary rods and conducting a full potential measurement. This is also referred to as the stakeless method.

AEMC MN82 Specifications

Range and Resolution 0.00 to 9.99mA: 0.01mA
10.0 to 99.9mA: 0.1mA
100 to 999mA: 1mA
1.00 to 9.99A: 0.01A
10 to 40A: 0.1A
Frequency Range and Accuracy (0.5 to 100mA) 16 to 49Hz: ±(15% + 2cts)
50 to 99Hz: ±(7% + 2cts)
100 to 400Hz: ±(5% + 2cts)
Frequency Range and Accuracy (0.1 to 40A) 16 to 49Hz: > 20%
50 to 99Hz: ±(15% + 2cts)
100 to 400Hz: ±(7% + 2cts)
Click here for complete specifications on the AEMC MN82

What's included with the AEMC MN82

  • AEMC MN82 AC Current Probe for the 6471 and 6472, 40A
  • Click on a category to view a selection of compatible accessories with the AEMC MN82 AC Current Probe for the 6471 and 6472, 40A.

    AEMC 2952.70 Replacement Lead for the SR182 and MN82, 6ft 2952.70
    Replacement 6 ft Extension Lead for use with the AEMC MN82 and SR182.




    Customer Reviews for the AEMC MN82

    Ask a question about AEMC MN82 AC Current Probe for the 6471 and 6472, 40A

    AEMC MN82 Offers

    When two MN82 probes are used in conjunction with the AEMC 6471 and 6472, grounding electrodes can be measured without the necessity of installing auxiliary rods and conducting a full potential measurement. This is also referred to as the stakeless method.

    AEMC MN82 Specifications

    Range and Resolution 0.00 to 9.99mA: 0.01mA
    10.0 to 99.9mA: 0.1mA
    100 to 999mA: 1mA
    1.00 to 9.99A: 0.01A
    10 to 40A: 0.1A
    Frequency Range and Accuracy (0.5 to 100mA) 16 to 49Hz: ±(15% + 2cts)
    50 to 99Hz: ±(7% + 2cts)
    100 to 400Hz: ±(5% + 2cts)
    Frequency Range and Accuracy (0.1 to 40A) 16 to 49Hz: > 20%
    50 to 99Hz: ±(15% + 2cts)
    100 to 400Hz: ±(7% + 2cts)
    Click here for complete specifications on the AEMC MN82

    What's included with the AEMC MN82

  • AEMC MN82 AC Current Probe for the 6471 and 6472, 40A
  • Click on a category to view a selection of compatible accessories with the AEMC MN82 AC Current Probe for the 6471 and 6472, 40A.

    AEMC 2952.70 Replacement Lead for the SR182 and MN82, 6ft 2952.70
    Replacement 6 ft Extension Lead for use with the AEMC MN82 and SR182.




    Ask a question about AEMC MN82 AC Current Probe for the 6471 and 6472, 40A

    Customer Reviews for the AEMC MN82

    More AEMC Products

    Calibration Lab