AEMC MN373 AC Current Probe, Lead, 100mV/A, 2.4A

Model: MN373 | Order No: 2116.28 | UPC: 685338030204

AEMC MN373 AC Current Probe, Lead, 100mV/A, 2.4A

Model: MN373 | Order No: 2116.28 | UPC: 685338030204

This small and compact Current Probe is designed to meet the most stringent demands in industry and electrical contracting. Model MN373 meets EN 61010, 600V, Cat. III safety standards and is CE Marked and UL approved for Canada and United States. Features a measurement range of 0.01 to 150A.

This small and compact Current Probe is designed to meet the most stringent demands in industry and electrical contracting. Model MN373 meets EN 61010, 600V, Cat. III safety standards and is CE Marked and UL approved for Canada and United States. Features a measurement range of 0.01 to 150A.

Sale Price $213.75 USD
Regular Price $225.00 USD
Availability 1 Week
Quantity

Add In-House Traceable Calibration to your MN373

Add In-House Traceable Calibration to your MN373


AEMC MN373 Offers

The MN373 is a dual range current probe designed to measure low current (to 200A) with high accuracy and phase shift. The MN373 has an integral 5 ft (1.5m) lead terminated by shrouded banana plugs.

Features

  • Small, compact size
  • Measurement range of 0.01 to 150A
  • Large jaw opening accommodates conductors up to 250MCM
  • Designed for DMMs, loggers, recorders and oscilloscopes
  • 40Hz to 10kHz response
  • 1000mV/A AC – 10mV/A AC output signals
  • Designed to EN 61010, 600V, Cat. III safety standard
  • UL approved for Canada and United States
  • Double Insulation
  • CE Mark

Applications

  • Measuring in breaker panels
  • Industrial loads
  • HVAC/R
  • Residential and commercial sites
  • 5A secondary current transformers (CTs) monitoring

AEMC MN373 Specifications

Nominal Range 2A & 150A
Measurement Range 0.1 to 150A
Transformation Ratio Voltage output
Output Signal 2A: 1000mV/A; 150A: 10mV/A
Accuracy (2A Range) 0.01 to 0.1A: 5% of Reading ± 2mV
0.1 to 1A: 3% of Reading ± 1mV
1 to 2.4A: 1% of Reading
Phase Shift (2A Range) Not Specified
Overload (2A Range) 2.4A for 10 min ON & 30 min OFF
Accuracy (150A Range) 0.1 to 1A: 3% of Reading ± 200µV
1 to 20A: 2% of Reading ± 200µV
20 to 80A: 1% of Reading
80 to 150A: 3% of Reading
150 to 200A: Not Specified
Phase Shift (150A Range) 0.1 to 1A: Not Specified
1 to 20A: ≤3°
20 to 80A: ≤2°
80 to 150A: ≤3°
150 to 200A: ≤4°
Overload 240A for 10 min ON, 30 min OFF
Frequency Range 40 to 10kHz
Limit Operating 200A permanently to 1kH
Derating above 3kHz: 200A x (1/0.333F), F in kHz to 1kHz
Crest Factor 2A: 3 at 2A Peak with an error (due to CF) of 3%
150A: 3 at 150A Peak with an error (due to CF) of 3%
Working/Common Mode Voltage 600Vrms
Output Termination 5ft Lead
Click here for complete specifications on the AEMC MN373

What's included with the AEMC MN373

  • AEMC MN373 AC Current Probe, Lead, 100mV/A, 2.4A
  • Customer Reviews for the AEMC MN373

    Ask a question about AEMC MN373 AC Current Probe, Lead, 100mV/A, 2.4A

    AEMC MN373 Offers

    The MN373 is a dual range current probe designed to measure low current (to 200A) with high accuracy and phase shift. The MN373 has an integral 5 ft (1.5m) lead terminated by shrouded banana plugs.

    Features

    • Small, compact size
    • Measurement range of 0.01 to 150A
    • Large jaw opening accommodates conductors up to 250MCM
    • Designed for DMMs, loggers, recorders and oscilloscopes
    • 40Hz to 10kHz response
    • 1000mV/A AC – 10mV/A AC output signals
    • Designed to EN 61010, 600V, Cat. III safety standard
    • UL approved for Canada and United States
    • Double Insulation
    • CE Mark

    Applications

    • Measuring in breaker panels
    • Industrial loads
    • HVAC/R
    • Residential and commercial sites
    • 5A secondary current transformers (CTs) monitoring

    AEMC MN373 Specifications

    Nominal Range 2A & 150A
    Measurement Range 0.1 to 150A
    Transformation Ratio Voltage output
    Output Signal 2A: 1000mV/A; 150A: 10mV/A
    Accuracy (2A Range) 0.01 to 0.1A: 5% of Reading ± 2mV
    0.1 to 1A: 3% of Reading ± 1mV
    1 to 2.4A: 1% of Reading
    Phase Shift (2A Range) Not Specified
    Overload (2A Range) 2.4A for 10 min ON & 30 min OFF
    Accuracy (150A Range) 0.1 to 1A: 3% of Reading ± 200µV
    1 to 20A: 2% of Reading ± 200µV
    20 to 80A: 1% of Reading
    80 to 150A: 3% of Reading
    150 to 200A: Not Specified
    Phase Shift (150A Range) 0.1 to 1A: Not Specified
    1 to 20A: ≤3°
    20 to 80A: ≤2°
    80 to 150A: ≤3°
    150 to 200A: ≤4°
    Overload 240A for 10 min ON, 30 min OFF
    Frequency Range 40 to 10kHz
    Limit Operating 200A permanently to 1kH
    Derating above 3kHz: 200A x (1/0.333F), F in kHz to 1kHz
    Crest Factor 2A: 3 at 2A Peak with an error (due to CF) of 3%
    150A: 3 at 150A Peak with an error (due to CF) of 3%
    Working/Common Mode Voltage 600Vrms
    Output Termination 5ft Lead
    Click here for complete specifications on the AEMC MN373

    What's included with the AEMC MN373

  • AEMC MN373 AC Current Probe, Lead, 100mV/A, 2.4A
  • Ask a question about AEMC MN373 AC Current Probe, Lead, 100mV/A, 2.4A

    Customer Reviews for the AEMC MN373

    More AEMC Products

    Calibration Lab