AEMC MN213 AC Current Probe, Lead, 1mA/A, 240A

Model: MN213 | Order No: 2115.75 | UPC: 685338030044

AEMC MN213 AC Current Probe, Lead, 1mA/A, 240A

Model: MN213 | Order No: 2115.75 | UPC: 685338030044

The latest in compact AC current probes. It is designed to meet the most stringent demands in industry and electrical contracting. This model meets EN 61010, 600V, Cat. III safety standards and is CE Marked and UL approved. With a small, compact size it features a measurement range of 0.5 to 240A AC.

The latest in compact AC current probes. It is designed to meet the most stringent demands in industry and electrical contracting. This model meets EN 61010, 600V, Cat. III safety standards and is CE Marked and UL approved. With a small, compact size it features a measurement range of 0.5 to 240A AC.

Sale Price $149.15 USD
Regular Price $157.00 USD
Availability 1 to 2 Weeks
Quantity

Add In-House Traceable Calibration to your MN213

Add In-House Traceable Calibration to your MN213


AEMC MN213 Offers

The MN213 is a general purpose AC current probe, which is designed for DMMs and other measuring instruments with current input. It has a 1000:1 ratio and an output of 1mA per Amp in the primary (inside the jaw). The MN213 has integral 5 ft (1.5m) leads terminated by shrouded banana plugs. The MN213 has protective diodes across the output that limit the voltage in the case if the open secondary.

Features

  • Small, compact size
  • Measurement range of 0.5 to 240A AC
  • Large jaw opening accommodates conductors up to 250MCM
  • Designed for DMMs, loggers, recorders and oscilloscopes
  • 40Hz to 10kHz response
  • 1mA AC/A AC output signals
  • Designed to EN 61010, 600V Cat. III safety standard
  • UL approved for Canada and United States
  • Double Insulation
  • CE Mark

Applications

  • Measuring in breaker panels
  • Industrial loads
  • HVAC/R
  • Residential and commercial sites
  • 5A secondary current transformers (CTs) monitoring
  • Data logging/recording

AEMC MN213 Specifications

Nominal Range 200A
Measurement Range 0.5 to 240A
Transformation Ratio 1000: 1
Output Signal 1mA/A on 1Ω
Accuracy (200A Range) 0.5 to 10A: 3.0% of Reading ± 0.5A
10 to 40A: 2.5% of Reading ± 0.5A
40 to 100A: 2.0% of Reading ± 0.5A
100 to 240A: 1.0% of Reading ± 0.5A
Phase Shift (200A Range) 0.5 to 10A: Not Specified
10 to 40A: ≤5.0°
40 to 100A ≤3.0°
100 to 240A: ≤2.5°
Overload 240A for 10 min ON, 30 min OFF
Frequency Range 40 to 10kHz
Limit Operating Conditions 200A permanently to 1kHz
Derating above 3kHz: 200A x (1/0.333F), F in kHz
Crest Factor 3 at 200Arms with an error (due to CF) of 4%
Working/Common Mode Voltage 600Vrms
Output Termination 5ft Lead
Click here for complete specifications on the AEMC MN213

What's included with the AEMC MN213

  • AEMC MN213 AC Current Probe, Lead, 1mA/A, 240A
  • Customer Reviews for the AEMC MN213

    Ask a question about AEMC MN213 AC Current Probe, Lead, 1mA/A, 240A

    AEMC MN213 Offers

    The MN213 is a general purpose AC current probe, which is designed for DMMs and other measuring instruments with current input. It has a 1000:1 ratio and an output of 1mA per Amp in the primary (inside the jaw). The MN213 has integral 5 ft (1.5m) leads terminated by shrouded banana plugs. The MN213 has protective diodes across the output that limit the voltage in the case if the open secondary.

    Features

    • Small, compact size
    • Measurement range of 0.5 to 240A AC
    • Large jaw opening accommodates conductors up to 250MCM
    • Designed for DMMs, loggers, recorders and oscilloscopes
    • 40Hz to 10kHz response
    • 1mA AC/A AC output signals
    • Designed to EN 61010, 600V Cat. III safety standard
    • UL approved for Canada and United States
    • Double Insulation
    • CE Mark

    Applications

    • Measuring in breaker panels
    • Industrial loads
    • HVAC/R
    • Residential and commercial sites
    • 5A secondary current transformers (CTs) monitoring
    • Data logging/recording

    AEMC MN213 Specifications

    Nominal Range 200A
    Measurement Range 0.5 to 240A
    Transformation Ratio 1000: 1
    Output Signal 1mA/A on 1Ω
    Accuracy (200A Range) 0.5 to 10A: 3.0% of Reading ± 0.5A
    10 to 40A: 2.5% of Reading ± 0.5A
    40 to 100A: 2.0% of Reading ± 0.5A
    100 to 240A: 1.0% of Reading ± 0.5A
    Phase Shift (200A Range) 0.5 to 10A: Not Specified
    10 to 40A: ≤5.0°
    40 to 100A ≤3.0°
    100 to 240A: ≤2.5°
    Overload 240A for 10 min ON, 30 min OFF
    Frequency Range 40 to 10kHz
    Limit Operating Conditions 200A permanently to 1kHz
    Derating above 3kHz: 200A x (1/0.333F), F in kHz
    Crest Factor 3 at 200Arms with an error (due to CF) of 4%
    Working/Common Mode Voltage 600Vrms
    Output Termination 5ft Lead
    Click here for complete specifications on the AEMC MN213

    What's included with the AEMC MN213

  • AEMC MN213 AC Current Probe, Lead, 1mA/A, 240A
  • Ask a question about AEMC MN213 AC Current Probe, Lead, 1mA/A, 240A

    Customer Reviews for the AEMC MN213

    More AEMC Products

    Calibration Lab