An all-in-one testing tool designed for electrical installation testing. Includes modes for testing voltage/current/frequency, insulation resistance, ground resistance, RCDs/GFCIs, active power, harmonics and phase rotation.
An all-in-one testing tool designed for electrical installation testing. Includes modes for testing voltage/current/frequency, insulation resistance, ground resistance, RCDs/GFCIs, active power, harmonics and phase rotation.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
Features
An all-in-one tool for electrical installation testing complying with the international standards (IEC 60364-6,NF C 15-100,VDE 100, XP C 16-600, etc). The Model C.A 6116 combines smart design, ergonomics, simplicity, rapid measurement and accuracy. Suitable for all types of neutral systems (TT, TN, IT), it can be used in all industrial, commercial and residential markets.
The C.A 6116 is specifically designed to be quick and easy to learn. The user can view all the essential results at a glance on the large backlit graphic display. The rotary switch on the instrument's front panel gives direct access to all the functions. A wide range of audible alarms and visual symbols are available for quick interpretation of the results in accordance with the standards.
Applications
| INSULATION | |
| Rated voltage | Utest: 50 /100 / 250 / 500 / 1000 V DC |
| Range / Resolution / Accuracy | 0.01 MΩ to 2 GΩ / 1 kΩto 1 MΩ / ±(5 % of measurement + 3 cts) |
| 3P EARTH | |
| Range / Resolution / Accuracy | 0.50 to 4 kΩ / 0.01 Ω to 1 Ω / ±(2 % of measurement + 2 cts) |
| Others | Auxiliary stake resistance measurement (up, to 40 kΩ) |
| EARTH WITH POWER ON | |
| Installation voltage / Frequency | 90 to 550 V / 15.3 to 17.5 Hz - 45 to 65 Hz |
| 1P EARTH | |
| High-current mode with tripping (TRIP) | Test current: 5 A |
| Range / Resolution / Accuracy | 0.10 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(5 % of measurement + 2 cts) |
| Mode without tripping (NO TRIP) | Test current: 6 mA – 9 mA – 12 mA (by default) |
| Range / Resolution / Accuracy | 0.20 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(5 % of measurement + 3 cts) |
| 1P SELECTIVE EARTH | |
| Range / Resolution / Accuracy | 0.20 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(10 % of measurement + 10 cts) |
| RCDs | |
| Installation voltage / Frequency | 90 V to 550 V / 15.3 Hz to 17.5 Hz / 45 Hz to 65 Hz |
| IΔn | 10/30/100/300/500/650/1,000 mA or variable - Test in step and pulse modes |
| No-trip test | at ½IΔn – Duration: 1,000 ms or 2,000 ms |
| Measurement of tripping time | at ½IΔn / 2 IΔn (selective) / 5 IΔn |
| Step mode | 0.3 IΔn to 1.06 IΔn in steps of 3.3 % IΔn |
| CONTINUITY | |
| Test voltage/ I rated | 9.5 VDC / I > 200 mA up to 39.99 Ω and 12 mA up to 399.9 kΩ with buzzer |
| Range / Resolution / Accuracy | 0 Ω to 399.9 kΩ / 0.01 Ω to 100 Ω / ±(1.5 % of measurement + 2 cts) |
| LOOP IMPEDANCE (Zi and Zs) | |
| High-current mode with tripping (TRIP) | Test current: 5 A |
| Range / Resolution / Accuracy | 0.1 Ω to 4,000 Ω/ 0.01 Ω to 1 Ω / ± (10 % of measurement + 5 cts) |
| NO TRIP mode (Zs only) | Test current: 6 mA – 9 mA – 12 mA (by default) |
| Range / Resolution / Accuracy | 0.2 Ω to 4,000 Ω / 0.01 Ω to 1 Ω / ± (10 % of measurement + 5 cts) |
| Calculation of short-circuit current | 0.1 A to 40 kA |
| Other | Measurement of the resistive and inductive components of the impedances Zs and Zi |
| CURRENT | 5 mA to 19.99 A (MN77 clamp) / 5 mA to 19.99 A (C177 clamp) / 20 mA to 200 A (C177A clamp) Current measurement from 1 mA available with MN77 & C177 by connecting voltage on the product |
| VOLTAGE | 0 to 550 V AC/DC |
| FREQUENCY | DC / 15.3 to 500 Hz |
| ACTIVE POWER | 0 to 110 kW single-phase - 0 to 330 kW three-phase Simultaneous display of of voltage and current waveforms. |
| HARMONICS | Voltage and current harmonics / Orders 0 to 50 / THD |
| PHASE ROTATION | 20 to 550 VAC |
| INSULATION | |
| Rated voltage | Utest: 50 /100 / 250 / 500 / 1000 V DC |
| Range / Resolution / Accuracy | 0.01 MΩ to 2 GΩ / 1 kΩto 1 MΩ / ±(5 % of measurement + 3 cts) |
| 3P EARTH | |
| Range / Resolution / Accuracy | 0.50 to 4 kΩ / 0.01 Ω to 1 Ω / ±(2 % of measurement + 2 cts) |
| Others | Auxiliary stake resistance measurement (up, to 40 kΩ) |
| EARTH WITH POWER ON | |
| Installation voltage / Frequency | 90 to 550 V / 15.3 to 17.5 Hz - 45 to 65 Hz |
| 1P EARTH | |
| High-current mode with tripping (TRIP) | Test current: 5 A |
| Range / Resolution / Accuracy | 0.10 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(5 % of measurement + 2 cts) |
| Mode without tripping (NO TRIP) | Test current: 6 mA – 9 mA – 12 mA (by default) |
| Range / Resolution / Accuracy | 0.20 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(5 % of measurement + 3 cts) |
| 1P SELECTIVE EARTH | |
| Range / Resolution / Accuracy | 0.20 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(10 % of measurement + 10 cts) |
| RCDs | |
| Installation voltage / Frequency | 90 V to 550 V / 15.3 Hz to 17.5 Hz / 45 Hz to 65 Hz |
| IΔn | 10/30/100/300/500/650/1,000 mA or variable - Test in step and pulse modes |
| No-trip test | at ½IΔn – Duration: 1,000 ms or 2,000 ms |
| Measurement of tripping time | at ½IΔn / 2 IΔn (selective) / 5 IΔn |
| Step mode | 0.3 IΔn to 1.06 IΔn in steps of 3.3 % IΔn |
| CONTINUITY | |
| Test voltage/ I rated | 9.5 VDC / I > 200 mA up to 39.99 Ω and 12 mA up to 399.9 kΩ with buzzer |
| Range / Resolution / Accuracy | 0 Ω to 399.9 kΩ / 0.01 Ω to 100 Ω / ±(1.5 % of measurement + 2 cts) |
| LOOP IMPEDANCE (Zi and Zs) | |
| High-current mode with tripping (TRIP) | Test current: 5 A |
| Range / Resolution / Accuracy | 0.1 Ω to 4,000 Ω/ 0.01 Ω to 1 Ω / ± (10 % of measurement + 5 cts) |
| NO TRIP mode (Zs only) | Test current: 6 mA – 9 mA – 12 mA (by default) |
| Range / Resolution / Accuracy | 0.2 Ω to 4,000 Ω / 0.01 Ω to 1 Ω / ± (10 % of measurement + 5 cts) |
| Calculation of short-circuit current | 0.1 A to 40 kA |
| Other | Measurement of the resistive and inductive components of the impedances Zs and Zi |
| CURRENT | 5 mA to 19.99 A (MN77 clamp) / 5 mA to 19.99 A (C177 clamp) / 20 mA to 200 A (C177A clamp) Current measurement from 1 mA available with MN77 & C177 by connecting voltage on the product |
| VOLTAGE | 0 to 550 V AC/DC |
| FREQUENCY | DC / 15.3 to 500 Hz |
| ACTIVE POWER | 0 to 110 kW single-phase - 0 to 330 kW three-phase Simultaneous display of of voltage and current waveforms. |
| HARMONICS | Voltage and current harmonics / Orders 0 to 50 / THD |
| PHASE ROTATION | 20 to 550 VAC |