AEMC C.A 6116 Multifunction Installation Tester

Model: C.A 6116 | Order No: 2138.01

AEMC C.A 6116 Multifunction Installation Tester

Model: C.A 6116 | Order No: 2138.01

An all-in-one testing tool designed for electrical installation testing. Includes modes for testing voltage/current/frequency, insulation resistance, ground resistance, RCDs/GFCIs, active power, harmonics and phase rotation.

An all-in-one testing tool designed for electrical installation testing. Includes modes for testing voltage/current/frequency, insulation resistance, ground resistance, RCDs/GFCIs, active power, harmonics and phase rotation.

This product has been discontinued. Contact us for more information.


An all-in-one tool for electrical installation testing complying with the international standards (IEC 60364-6,NF C 15-100,VDE 100, XP C 16-600, etc). The Model C.A 6116 combines smart design, ergonomics, simplicity, rapid measurement and accuracy. Suitable for all types of neutral systems (TT, TN, IT), it can be used in all industrial, commercial and residential markets.

The C.A 6116 is specifically designed to be quick and easy to learn. The user can view all the essential results at a glance on the large backlit graphic display. The rotary switch on the instrument's front panel gives direct access to all the functions. A wide range of audible alarms and visual symbols are available for quick interpretation of the results in accordance with the standards.


Applications

  • Initial electrical testing of a new installation
  • Electrical testing after renovation
  • Periodic testing of an installation
  • Maintenance and troubleshooting on an installation

Key Features

  • Installation testing according to the international standards(IEC 60364-6,NF C 15-100,VDE 100, XP C 16-600)
  • Fast operation with simple access to measurement functions and results
  • User-friendly with its large 5.7" backlit graphic screen
  • Excellent measurement stability, especially in industrial environments that are affected by disturbances
  • Simple, reliable connections
  • Onscreen help for each function
  • Suitable for all types of neutral systems
  • Customized, hierarchical storage of measurement results
  • 600V CAT III

Specifications

INSULATION
Rated voltage Utest: 50 /100 / 250 / 500 / 1000 V DC
Range / Resolution / Accuracy 0.01 MΩ to 2 GΩ / 1 kΩto 1 MΩ / ±(5 % of measurement + 3 cts)
EART H
3P EARTH
Range / Resolution / Accuracy 0.50 to 4 kΩ / 0.01 Ω to 1 Ω / ±(2 % of measurement + 2 cts)
Others Auxiliary stake resistance measurement (up, to 40 kΩ)
EARTH WITH POWER ON
Installation voltage / Frequency 90 to 550 V / 15.3 to 17.5 Hz - 45 to 65 Hz
1P EARTH
High-current mode with tripping (TRIP) Test current: 5 A
Range / Resolution / Accuracy 0.10 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(5 % of measurement + 2 cts)
Mode without tripping (NO TRIP) Test current: 6 mA – 9 mA – 12 mA (by default)
Range / Resolution / Accuracy 0.20 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(5 % of measurement + 3 cts)
1P SELECTIVE EARTH
Range / Resolution / Accuracy 0.20 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(10 % of measurement + 10 cts)
RCDs
Installation voltage / Frequency 90 V to 550 V / 15.3 Hz to 17.5 Hz / 45 Hz to 65 Hz
IΔn 10/30/100/300/500/650/1,000 mA or variable - Test in step and pulse modes
No-trip test at ½IΔn – Duration: 1,000 ms or 2,000 ms
Measurement of tripping time at ½IΔn / 2 IΔn (selective) / 5 IΔn
Step mode 0.3 IΔn to 1.06 IΔn in steps of 3.3 % IΔn
CONTINUITY
Test voltage/ I rated 9.5 VDC / I > 200 mA up to 39.99 Ω and 12 mA up to 399.9 kΩ with buzzer
Range / Resolution / Accuracy 0 Ω to 399.9 kΩ / 0.01 Ω to 100 Ω / ±(1.5 % of measurement + 2 cts)
LOOP IMPEDANCE (Zi and Zs)
High-current mode with tripping (TRIP) Test current: 5 A
Range / Resolution / Accuracy 0.1 Ω to 4,000 Ω/ 0.01 Ω to 1 Ω / ± (10 % of measurement + 5 cts)
NO TRIP mode (Zs only) Test current: 6 mA – 9 mA – 12 mA (by default)
Range / Resolution / Accuracy 0.2 Ω to 4,000 Ω / 0.01 Ω to 1 Ω / ± (10 % of measurement + 5 cts)
Calculation of short-circuit current 0.1 A to 40 kA
Other Measurement of the resistive and inductive components of the impedances Zs and Zi
CURRENT 5 mA to 19.99 A (MN77 clamp) / 5 mA to 19.99 A (C177 clamp) / 20 mA to 200 A (C177A clamp) Current measurement from 1 mA available with MN77 & C177 by connecting voltage on the product
VOLTAGE 0 to 550 V AC/DC
FREQUENCY DC / 15.3 to 500 Hz
ACTIVE POWER 0 to 110 kW single-phase - 0 to 330 kW three-phase Simultaneous display of of voltage and current waveforms.
HARMONICS Voltage and current harmonics / Orders 0 to 50 / THD
PHASE ROTATION 20 to 550 VAC

What's included with the AEMC C.A 6116

  • AEMC C.A 6116 Multifunction Installation Tester
  • Customer Reviews for the AEMC C.A 6116

    Ask a question about AEMC C.A 6116 Multifunction Installation Tester

    An all-in-one tool for electrical installation testing complying with the international standards (IEC 60364-6,NF C 15-100,VDE 100, XP C 16-600, etc). The Model C.A 6116 combines smart design, ergonomics, simplicity, rapid measurement and accuracy. Suitable for all types of neutral systems (TT, TN, IT), it can be used in all industrial, commercial and residential markets.

    The C.A 6116 is specifically designed to be quick and easy to learn. The user can view all the essential results at a glance on the large backlit graphic display. The rotary switch on the instrument's front panel gives direct access to all the functions. A wide range of audible alarms and visual symbols are available for quick interpretation of the results in accordance with the standards.


    Applications

    • Initial electrical testing of a new installation
    • Electrical testing after renovation
    • Periodic testing of an installation
    • Maintenance and troubleshooting on an installation

    Key Features

    • Installation testing according to the international standards(IEC 60364-6,NF C 15-100,VDE 100, XP C 16-600)
    • Fast operation with simple access to measurement functions and results
    • User-friendly with its large 5.7" backlit graphic screen
    • Excellent measurement stability, especially in industrial environments that are affected by disturbances
    • Simple, reliable connections
    • Onscreen help for each function
    • Suitable for all types of neutral systems
    • Customized, hierarchical storage of measurement results
    • 600V CAT III

    Specifications

    INSULATION
    Rated voltage Utest: 50 /100 / 250 / 500 / 1000 V DC
    Range / Resolution / Accuracy 0.01 MΩ to 2 GΩ / 1 kΩto 1 MΩ / ±(5 % of measurement + 3 cts)
    EART H
    3P EARTH
    Range / Resolution / Accuracy 0.50 to 4 kΩ / 0.01 Ω to 1 Ω / ±(2 % of measurement + 2 cts)
    Others Auxiliary stake resistance measurement (up, to 40 kΩ)
    EARTH WITH POWER ON
    Installation voltage / Frequency 90 to 550 V / 15.3 to 17.5 Hz - 45 to 65 Hz
    1P EARTH
    High-current mode with tripping (TRIP) Test current: 5 A
    Range / Resolution / Accuracy 0.10 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(5 % of measurement + 2 cts)
    Mode without tripping (NO TRIP) Test current: 6 mA – 9 mA – 12 mA (by default)
    Range / Resolution / Accuracy 0.20 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(5 % of measurement + 3 cts)
    1P SELECTIVE EARTH
    Range / Resolution / Accuracy 0.20 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(10 % of measurement + 10 cts)
    RCDs
    Installation voltage / Frequency 90 V to 550 V / 15.3 Hz to 17.5 Hz / 45 Hz to 65 Hz
    IΔn 10/30/100/300/500/650/1,000 mA or variable - Test in step and pulse modes
    No-trip test at ½IΔn – Duration: 1,000 ms or 2,000 ms
    Measurement of tripping time at ½IΔn / 2 IΔn (selective) / 5 IΔn
    Step mode 0.3 IΔn to 1.06 IΔn in steps of 3.3 % IΔn
    CONTINUITY
    Test voltage/ I rated 9.5 VDC / I > 200 mA up to 39.99 Ω and 12 mA up to 399.9 kΩ with buzzer
    Range / Resolution / Accuracy 0 Ω to 399.9 kΩ / 0.01 Ω to 100 Ω / ±(1.5 % of measurement + 2 cts)
    LOOP IMPEDANCE (Zi and Zs)
    High-current mode with tripping (TRIP) Test current: 5 A
    Range / Resolution / Accuracy 0.1 Ω to 4,000 Ω/ 0.01 Ω to 1 Ω / ± (10 % of measurement + 5 cts)
    NO TRIP mode (Zs only) Test current: 6 mA – 9 mA – 12 mA (by default)
    Range / Resolution / Accuracy 0.2 Ω to 4,000 Ω / 0.01 Ω to 1 Ω / ± (10 % of measurement + 5 cts)
    Calculation of short-circuit current 0.1 A to 40 kA
    Other Measurement of the resistive and inductive components of the impedances Zs and Zi
    CURRENT 5 mA to 19.99 A (MN77 clamp) / 5 mA to 19.99 A (C177 clamp) / 20 mA to 200 A (C177A clamp) Current measurement from 1 mA available with MN77 & C177 by connecting voltage on the product
    VOLTAGE 0 to 550 V AC/DC
    FREQUENCY DC / 15.3 to 500 Hz
    ACTIVE POWER 0 to 110 kW single-phase - 0 to 330 kW three-phase Simultaneous display of of voltage and current waveforms.
    HARMONICS Voltage and current harmonics / Orders 0 to 50 / THD
    PHASE ROTATION 20 to 550 VAC

    What's included with the AEMC C.A 6116

  • AEMC C.A 6116 Multifunction Installation Tester
  • Ask a question about AEMC C.A 6116 Multifunction Installation Tester

    Customer Reviews for the AEMC C.A 6116

    More AEMC Products