AEMC 502 True RMS Clamp Meter, 400A AC, 600V AC/DC

Model: 502 | Order No: 2117.66 | UPC: 685338110036

AEMC 502 True RMS Clamp Meter, 400A AC, 600V AC/DC

Model: 502 | Order No: 2117.66 | UPC: 685338110036

A strong mechanical case design, quality materials, full ranges and compliance to international safety and quality standards ensure a professional and reliable tool. Measures True RMS, 400A AC, 600V AC/DC, Ohms, and Continuity.

A strong mechanical case design, quality materials, full ranges and compliance to international safety and quality standards ensure a professional and reliable tool. Measures True RMS, 400A AC, 600V AC/DC, Ohms, and Continuity.

This product has been discontinued. Click here for the replacement model(s).


AEMC 502 Offers

The AEMC 502 Clamp-on Meter is a general-purpose professional clamp-on. It is a True RMS clamp-on which provides RMS measurements for measuring in non-linear electrical environments.

This clamp-on multimeter is auto-ranging, and provides the user with AAC,VAC, VDC, Ohms, Continuity, as well as a frequency measurement function. The jaw opening for the Model 502 is 1.1" (28mm).

Features

  • Compact size - fits into your pocket
  • 400AAC current measurements
  • 600VAC volts measurements
  • Resistance measurements to 400Ω
  • Continuity with beeper below 35Ω
  • Hold function to "freeze" readings
  • Large easy-to-read 4000-count display
  • 42-segment bargraph
  • Includes test leads and a soft carrying pouch

Applications

  • Industrial, commercial, HVAC/R and residential troubleshooting
  • Power panel, junction box and battery bank monitoring
  • Electrical testing and troubleshooting on traditional and non-linear leads, such as adjustable speed drives and computers

AEMC 502 Specifications

AC Current
Range 0.05 to 400A
Resolution 40A: 0.01A
400A: 0.1A
Basic Accuracy 50 to 60Hz: ±1.9% of Reading + 5cts; 60 to 500Hz: ±2.5% of Reading + 5cts
Frequency Range 50 to 500Hz
Overload Protection 600Arms
DC Amperes
Range 0.10 to 400A
Resolution 40A: 0.1V
400A: 0.1A
Accuracy ±2.5% of Reading + 10cts
Overload Protection 600Arms
AC Volts
Input Range 0.5 to 600V
Range 400V / 600V
Resolution 0.1V / 1V
Accuracy 50 to 60Hz: ±0.8% of Reading + 5cts; 60 to 500Hz: ±1.5% of Reading + 5cts
Input Impedance 10MW
Overload Protection 600Vrms
Frequency Voltage Input
Range 4kHz, 40kHz, 400kHz
Resolution 1Hz, 10Hz, 100Hz
Minimum Input Signal 5Vrms
Accuracy ±0.1% of Reading + 1ct
Input Impedance 10MW
Overload Protection 600Vrms
DC Volts
Range 0.2 to 600V
Resolution 400V: 0.1V; 600V: 1V
Accuracy ±1% of Reading + 2cts
Input Impedance 10MW
Overload Protection 600Vrms
Continuity
Range Beeper
Measurement <40W
Max. Test Voltage 1.5VDC
Overload Protection 600Vrms
General Specifications
Jaw Opening Size 1.02" (26mm)
Battery Two 1.5V AAA batteries
Low Battery Indicator Symbol displayed when the battery is below the required voltage
Auto Power Off The meter will power itself OFF if there is no push button or rotary switch operation for 30 minutes
Dimensions 7.60 x 1.97 x 1.1" (193 x 50 x 28mm)
Weight 8.11oz (230g) with batteries

What's Included with the AEMC 502

  • AC Clamp-on Meter
  • Set of Two Test Leads
  • Soft Carrying Case
  • 2 x 1.5V AAA Batteries
  • Manual

Customer Reviews for the AEMC 502

Ask a question about AEMC 502 True RMS Clamp Meter, 400A AC, 600V AC/DC

AEMC 502 Offers

The AEMC 502 Clamp-on Meter is a general-purpose professional clamp-on. It is a True RMS clamp-on which provides RMS measurements for measuring in non-linear electrical environments.

This clamp-on multimeter is auto-ranging, and provides the user with AAC,VAC, VDC, Ohms, Continuity, as well as a frequency measurement function. The jaw opening for the Model 502 is 1.1" (28mm).

Features

  • Compact size - fits into your pocket
  • 400AAC current measurements
  • 600VAC volts measurements
  • Resistance measurements to 400Ω
  • Continuity with beeper below 35Ω
  • Hold function to "freeze" readings
  • Large easy-to-read 4000-count display
  • 42-segment bargraph
  • Includes test leads and a soft carrying pouch

Applications

  • Industrial, commercial, HVAC/R and residential troubleshooting
  • Power panel, junction box and battery bank monitoring
  • Electrical testing and troubleshooting on traditional and non-linear leads, such as adjustable speed drives and computers

AEMC 502 Specifications

AC Current
Range 0.05 to 400A
Resolution 40A: 0.01A
400A: 0.1A
Basic Accuracy 50 to 60Hz: ±1.9% of Reading + 5cts; 60 to 500Hz: ±2.5% of Reading + 5cts
Frequency Range 50 to 500Hz
Overload Protection 600Arms
DC Amperes
Range 0.10 to 400A
Resolution 40A: 0.1V
400A: 0.1A
Accuracy ±2.5% of Reading + 10cts
Overload Protection 600Arms
AC Volts
Input Range 0.5 to 600V
Range 400V / 600V
Resolution 0.1V / 1V
Accuracy 50 to 60Hz: ±0.8% of Reading + 5cts; 60 to 500Hz: ±1.5% of Reading + 5cts
Input Impedance 10MW
Overload Protection 600Vrms
Frequency Voltage Input
Range 4kHz, 40kHz, 400kHz
Resolution 1Hz, 10Hz, 100Hz
Minimum Input Signal 5Vrms
Accuracy ±0.1% of Reading + 1ct
Input Impedance 10MW
Overload Protection 600Vrms
DC Volts
Range 0.2 to 600V
Resolution 400V: 0.1V; 600V: 1V
Accuracy ±1% of Reading + 2cts
Input Impedance 10MW
Overload Protection 600Vrms
Continuity
Range Beeper
Measurement <40W
Max. Test Voltage 1.5VDC
Overload Protection 600Vrms
General Specifications
Jaw Opening Size 1.02" (26mm)
Battery Two 1.5V AAA batteries
Low Battery Indicator Symbol displayed when the battery is below the required voltage
Auto Power Off The meter will power itself OFF if there is no push button or rotary switch operation for 30 minutes
Dimensions 7.60 x 1.97 x 1.1" (193 x 50 x 28mm)
Weight 8.11oz (230g) with batteries

What's Included with the AEMC 502

  • AC Clamp-on Meter
  • Set of Two Test Leads
  • Soft Carrying Case
  • 2 x 1.5V AAA Batteries
  • Manual

Ask a question about AEMC 502 True RMS Clamp Meter, 400A AC, 600V AC/DC

Customer Reviews for the AEMC 502

More AEMC Products

Calibration Lab