AEMC 3711 Clamp-on Ground Resistance Tester

Model: 3711 | Order No: 2117.60

AEMC 3711 Clamp-on Ground Resistance Tester

Model: 3711 | Order No: 2117.60

Industry-leading clamp-on ground resistance tester from the company that invented the concept.

Industry-leading clamp-on ground resistance tester from the company that invented the concept.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

AEMC 6417 Clamp-On Ground Resistance Tester with Bluetooth, 1500 Ω, 40 A-

AEMC 6417 Clamp-On Ground Resistance Tester with Bluetooth, 1500 Ω, 40 A

Model: 6417 | Order No: 2141.02

Use this ground resistance tester to measure grounding electrodes and grid resistance without auxiliary rods. In addition, the clamp-on feature can be used in multi-grounded systems without disconnecting the ground system under test by simply clamping around the ground conductor or rod and measuring the resistance to the ground.


AEMC Instruments 3711 Offers

Key Features

  • Simple and fast clamp-on operation - no leads, no auxiliary rods or spacing requirements. No need to disconnect neutral service
  • Direct reading of ground resistance from 0.01Ω to 1200Ω
  • Direct reading of continuity and ground loop resistance
  • Direct reading of ground leakage or phase current from 1mA to 30Arms
  • Jaw design with large 1.25" (32mm) window - accommodates up to 1000MCM cables
  • Auto-off for power management
  • CE Mark and UL approved
  • Rugged Lexan head and body construction resists breakage
  • Patented design

Check Resistance on Single and Multiple Rods or Grids

The

AEMC 3711 Clamp-on Ground Resistance Tester

measures ground rod and small grid resistance in any environment without the use of auxiliary ground rods.

This Clamp-on Ground Resistance Tester is used on multi-grounded systems without disconnecting the ground under test. Simply clamps around the ground conductor or rod and measures the resistance to ground fast and accurately. By performing measurements on intact ground systems, the user also verifies the quality of the grounding connections and bonds. Resistance and continuity of grounding loops around pads and buildings may also be measured.

This AEMC 3711 Clamp-on Ground Resistance Tester includes a current measurement function. The probe's high sensitivity enables measurement of leakage current flowing to ground or circulating in ground loops down to 1mA and neutral and phase currents to 30Arms. This feature provides additional information which is vital in distribution ground networks carrying higher levels of noise and harmonics that affect power quality.


Applications

  • Measure electrical ground rod and grid resistance
  • Use on multi-grounded systems without disconnecting the ground rod under test
  • Measure resistance and continuity of grounding loops around pads and buildings
  • Measure leakage current flowing to ground or circulating in ground systems
  • Conduct field surveys and retrieve and analyze readings at a later time
  • Use on cell towers and telecommunication sites
  • Use on pools, spas and other consumer installations

For greater capabilities see the AEMC 3731 Clamp-on Ground Resistance Tester


  • Hard carrying case
  • 9V Alkaline battery
  • 25½ calibration check loop
  • User manual

AEMC Instruments 3711 Specifications

Measurement Range
Type Ground Resistance Ranges
Range Autoranging 0.01 to 1200Ω
Measurement Range 0.10 to 1.00Ω / 1.0 to 50.0Ω / 50.0 to 100.0W / 100 to 200Ω / 200 to 400Ω / 400 to 600Ω
Resolution 0.01Ω / 0.1Ω / 0.5Ω / 1Ω / 5Ω / 10Ω
Accuracy in % of Reading ± (2% Reading ± 0.02Ω ) / ± (1.5% Reading ± 0.1Ω ) / ± (2.0% Reading ± 0.5Ω ) / ± (3.0% Reading ± 1Ω ) / ± (6% Reading ± 5Ω ) / ± (10% Reading ± 10Ω )
Resistance Measurement Frequency 1.689kHz
Resistance Overload OL displayed above 1200Ω
Current Measurement Frequency 47 to 800Hz
Current Overload OL displayed above 30Arms
Power Source 9V Alkaline battery
Battery Life typical: 8 hours or approx. 1,000 measurements of 30 seconds
Mechanical Specifications
Display 3-3/4 Digit, 1.73" x 1.10" (44 x 28mm)
Operating Temperature 14° to 131°F (-10° to 55°C)
Storage Temperature 40° to 158°F (-40°C to 70°C)
Relative Humidity 0 to 90% RH @ 14 to 104°F (-10°C to 40°C), 75% RH @ 131°F (55°C)
Dimensions 9.25 x 3.94 x 2.17" (235 x 100 x 55mm)
Jaw Window Diameter 1.25" (32mm)
Jaw Opening 1.38" (35m)
Case Lexan 920A (UL94V)
Colors Gray body, red jaws
Shock Test IEC 68-2-27
Vibration Test IEC 68-2-6
Drop Test (1m); IEC 68-2-32
Dielectric Test 2500VAC
Environmental IP30, IEC 359 Group III
Working Voltage 150V Cat. III - Pollution Degree 2 300V, Cat. II - Pollution Degree 1
Max Overload (A or OHM Function) 100A continuous, 200A (<5s) 50/60Hz</td>
Safety Reference Specifications
Safety Ratings IEC 1010, 150V, Cat. III; IEC 1010, 300V, Cat. III
Agency Approvals CE Mark, UL, CSA

What's included with the AEMC Instruments 3711

  • AEMC 3711 Clamp-on Ground Resistance Tester

Ask a question about AEMC 3711 Clamp-on Ground Resistance Tester

Customer Reviews for the AEMC Instruments 3711

AEMC Instruments 3711 Offers

Key Features

  • Simple and fast clamp-on operation - no leads, no auxiliary rods or spacing requirements. No need to disconnect neutral service
  • Direct reading of ground resistance from 0.01Ω to 1200Ω
  • Direct reading of continuity and ground loop resistance
  • Direct reading of ground leakage or phase current from 1mA to 30Arms
  • Jaw design with large 1.25" (32mm) window - accommodates up to 1000MCM cables
  • Auto-off for power management
  • CE Mark and UL approved
  • Rugged Lexan head and body construction resists breakage
  • Patented design

Check Resistance on Single and Multiple Rods or Grids

The

AEMC 3711 Clamp-on Ground Resistance Tester

measures ground rod and small grid resistance in any environment without the use of auxiliary ground rods.

This Clamp-on Ground Resistance Tester is used on multi-grounded systems without disconnecting the ground under test. Simply clamps around the ground conductor or rod and measures the resistance to ground fast and accurately. By performing measurements on intact ground systems, the user also verifies the quality of the grounding connections and bonds. Resistance and continuity of grounding loops around pads and buildings may also be measured.

This AEMC 3711 Clamp-on Ground Resistance Tester includes a current measurement function. The probe's high sensitivity enables measurement of leakage current flowing to ground or circulating in ground loops down to 1mA and neutral and phase currents to 30Arms. This feature provides additional information which is vital in distribution ground networks carrying higher levels of noise and harmonics that affect power quality.


Applications

  • Measure electrical ground rod and grid resistance
  • Use on multi-grounded systems without disconnecting the ground rod under test
  • Measure resistance and continuity of grounding loops around pads and buildings
  • Measure leakage current flowing to ground or circulating in ground systems
  • Conduct field surveys and retrieve and analyze readings at a later time
  • Use on cell towers and telecommunication sites
  • Use on pools, spas and other consumer installations

For greater capabilities see the AEMC 3731 Clamp-on Ground Resistance Tester


  • Hard carrying case
  • 9V Alkaline battery
  • 25½ calibration check loop
  • User manual

AEMC Instruments 3711 Specifications

Measurement Range
Type Ground Resistance Ranges
Range Autoranging 0.01 to 1200Ω
Measurement Range 0.10 to 1.00Ω / 1.0 to 50.0Ω / 50.0 to 100.0W / 100 to 200Ω / 200 to 400Ω / 400 to 600Ω
Resolution 0.01Ω / 0.1Ω / 0.5Ω / 1Ω / 5Ω / 10Ω
Accuracy in % of Reading ± (2% Reading ± 0.02Ω ) / ± (1.5% Reading ± 0.1Ω ) / ± (2.0% Reading ± 0.5Ω ) / ± (3.0% Reading ± 1Ω ) / ± (6% Reading ± 5Ω ) / ± (10% Reading ± 10Ω )
Resistance Measurement Frequency 1.689kHz
Resistance Overload OL displayed above 1200Ω
Current Measurement Frequency 47 to 800Hz
Current Overload OL displayed above 30Arms
Power Source 9V Alkaline battery
Battery Life typical: 8 hours or approx. 1,000 measurements of 30 seconds
Mechanical Specifications
Display 3-3/4 Digit, 1.73" x 1.10" (44 x 28mm)
Operating Temperature 14° to 131°F (-10° to 55°C)
Storage Temperature 40° to 158°F (-40°C to 70°C)
Relative Humidity 0 to 90% RH @ 14 to 104°F (-10°C to 40°C), 75% RH @ 131°F (55°C)
Dimensions 9.25 x 3.94 x 2.17" (235 x 100 x 55mm)
Jaw Window Diameter 1.25" (32mm)
Jaw Opening 1.38" (35m)
Case Lexan 920A (UL94V)
Colors Gray body, red jaws
Shock Test IEC 68-2-27
Vibration Test IEC 68-2-6
Drop Test (1m); IEC 68-2-32
Dielectric Test 2500VAC
Environmental IP30, IEC 359 Group III
Working Voltage 150V Cat. III - Pollution Degree 2 300V, Cat. II - Pollution Degree 1
Max Overload (A or OHM Function) 100A continuous, 200A (<5s) 50/60Hz</td>
Safety Reference Specifications
Safety Ratings IEC 1010, 150V, Cat. III; IEC 1010, 300V, Cat. III
Agency Approvals CE Mark, UL, CSA

What's included with the AEMC Instruments 3711

  • AEMC 3711 Clamp-on Ground Resistance Tester

Ask a question about AEMC 3711 Clamp-on Ground Resistance Tester

Customer Reviews for the AEMC Instruments 3711