Additel AM1751-12-SP Secondary Reference PRT Probe, 12 x 0.25", -328 to 1238°F, spade lugs

Model: AM1751-12-SP

Additel AM1751-12-SP Secondary Reference PRT Probe, 12 x 0.25", -328 to 1238°F, spade lugs

Model: AM1751-12-SP

Built for furnace and bath calibration, this secondary reference PRT measures from -328 to 1238°F and holds ±0.015°C accuracy at the triple point of water. An Inconel sheath protects the 100 ohm platinum sensor to 670°C along a 12" stem, while the four spade lugs fit any 4-wire terminal, and an Additel 9071 adapter bridges them to an ADT282.

Built for furnace and bath calibration, this secondary reference PRT measures from -328 to 1238°F and holds ±0.015°C accuracy at the triple point of water. An Inconel sheath protects the 100 ohm platinum sensor to 670°C along a 12" stem, while the four spade lugs fit any 4-wire terminal, and an Additel 9071 adapter bridges them to an ADT282.

Your Price $3021.00 USD
Availability 2 to 3 Weeks
Quantity

Additel AM1751-12-SP Offers

Features

  • 100 Ω platinum sensor with a 0.003925 Ω/Ω/°C temperature coefficient, fully meeting the ITS-90 criteria for reference thermometers
  • Calibrated accuracy of ±0.015°C at the triple point of water, ±0.025°C at -40°C and ±0.05°C at 661°C
  • Measures -328 to 1238°F (-200 to 670°C)
  • Long term drift under 0.01°C at the triple point of water after 100 hours at 661°C
  • Short term stability under 0.007°C and hysteresis of 0.005°C
  • Thermal shock under 0.005°C after 10 thermal cycles from minimum to maximum temperature
  • Inconel™ sheath protects the sensing element from contamination up to 670°C
  • 32 mm sensing element sits 3 mm from the tip for fast, well-defined immersion
  • 0.25" (6.35 mm) stem, 12" (305 mm) long
  • 9 second response to 63% of a step change in water moving at 1 meter per second
  • Four-wire spade lugs terminate the leads for any readout that accepts them; an Additel 9071 adapter is required to reach an ADT282 smart connector port
  • Teflon™ insulated copper leads, 4 conductors, 6.5 feet (2 meters) long
  • Handle rated -58 to 356°F (-50 to 180°C)

Applications

  • Comparison calibration of RTDs, thermocouples and thermistors against a reference
  • Reference channel on a precision thermometer readout
  • Temperature loop verification in the instrument shop
  • Dry-well, fluid-bath and furnace calibration across an extended range
  • Cryogenic work down to liquid nitrogen temperatures

Additel AM1751-12-SP Specifications

Measurement
Temperature Range -328 to 1238°F (-200 to 670°C)
Calibrated Accuracy (k=2) ±0.025°C at -40°C
±0.015°C at 0.01°C
±0.035°C at 420°C
±0.05°C at 661°C
Nominal Resistance at 0.01°C 100 Ω
Temperature Coefficient 0.003925 Ω/Ω/°C
Long Term Drift <0.01°C at TPW after 100 hours at 661°C
Short Term Stability <0.007°C
Thermal Shock <0.005°C after 10 thermal cycles from minimum to maximum temperatures
Hysteresis 0.005°C
Self-Heating 50 mW/°C
Response Time 9 seconds for 63% response to a step change in water moving at 1 meter per second
Measurement Current 0.5 mA or 1 mA
Sensor Length 1.26" (32 mm)
Sensor Location 0.12" (3 mm) from tip
Insulation Resistance >1000 MΩ at room temperature
General
Sheath Material Inconel™
Sheath Dimensions 0.25" (6.35 mm) OD x 12" (305 mm) L
Connector Four-wire spade lugs
External Leads Teflon™ insulated copper wire, 4 leads, 6.5 feet (2 meters)
Handle Dimensions 0.59" (15 mm) OD x 2.56" (65 mm) L
Handle Temperature Range -58 to 356°F (-50 to 180°C)
Calibration ISO 17025 accredited calibration
Click here for complete specifications on the Additel AM1751-12-SP

What's included with the Additel AM1751-12-SP

  • Secondary Reference PRT Probe
  • ISO 17025 Accredited Calibration Certificate

Ask a question about Additel AM1751-12-SP Secondary Reference PRT Probe, 12 x 0.25", -328 to 1238°F, spade lugs

Customer Reviews for the Additel AM1751-12-SP

Additel AM1751-12-SP Offers

Features

  • 100 Ω platinum sensor with a 0.003925 Ω/Ω/°C temperature coefficient, fully meeting the ITS-90 criteria for reference thermometers
  • Calibrated accuracy of ±0.015°C at the triple point of water, ±0.025°C at -40°C and ±0.05°C at 661°C
  • Measures -328 to 1238°F (-200 to 670°C)
  • Long term drift under 0.01°C at the triple point of water after 100 hours at 661°C
  • Short term stability under 0.007°C and hysteresis of 0.005°C
  • Thermal shock under 0.005°C after 10 thermal cycles from minimum to maximum temperature
  • Inconel™ sheath protects the sensing element from contamination up to 670°C
  • 32 mm sensing element sits 3 mm from the tip for fast, well-defined immersion
  • 0.25" (6.35 mm) stem, 12" (305 mm) long
  • 9 second response to 63% of a step change in water moving at 1 meter per second
  • Four-wire spade lugs terminate the leads for any readout that accepts them; an Additel 9071 adapter is required to reach an ADT282 smart connector port
  • Teflon™ insulated copper leads, 4 conductors, 6.5 feet (2 meters) long
  • Handle rated -58 to 356°F (-50 to 180°C)

Applications

  • Comparison calibration of RTDs, thermocouples and thermistors against a reference
  • Reference channel on a precision thermometer readout
  • Temperature loop verification in the instrument shop
  • Dry-well, fluid-bath and furnace calibration across an extended range
  • Cryogenic work down to liquid nitrogen temperatures

Additel AM1751-12-SP Specifications

Measurement
Temperature Range -328 to 1238°F (-200 to 670°C)
Calibrated Accuracy (k=2) ±0.025°C at -40°C
±0.015°C at 0.01°C
±0.035°C at 420°C
±0.05°C at 661°C
Nominal Resistance at 0.01°C 100 Ω
Temperature Coefficient 0.003925 Ω/Ω/°C
Long Term Drift <0.01°C at TPW after 100 hours at 661°C
Short Term Stability <0.007°C
Thermal Shock <0.005°C after 10 thermal cycles from minimum to maximum temperatures
Hysteresis 0.005°C
Self-Heating 50 mW/°C
Response Time 9 seconds for 63% response to a step change in water moving at 1 meter per second
Measurement Current 0.5 mA or 1 mA
Sensor Length 1.26" (32 mm)
Sensor Location 0.12" (3 mm) from tip
Insulation Resistance >1000 MΩ at room temperature
General
Sheath Material Inconel™
Sheath Dimensions 0.25" (6.35 mm) OD x 12" (305 mm) L
Connector Four-wire spade lugs
External Leads Teflon™ insulated copper wire, 4 leads, 6.5 feet (2 meters)
Handle Dimensions 0.59" (15 mm) OD x 2.56" (65 mm) L
Handle Temperature Range -58 to 356°F (-50 to 180°C)
Calibration ISO 17025 accredited calibration
Click here for complete specifications on the Additel AM1751-12-SP

What's included with the Additel AM1751-12-SP

  • Secondary Reference PRT Probe
  • ISO 17025 Accredited Calibration Certificate

Ask a question about Additel AM1751-12-SP Secondary Reference PRT Probe, 12 x 0.25", -328 to 1238°F, spade lugs