Lightweight and compact, this portable automated pressure calibrator features an accuracy of 0.02% FS and provides a range of -12.5 to 35 psi (-0.86 to 2.5 bar). With a built-in pump, precision pressure sensor, and internal controller, this calibrator comes complete with four channels and a large touch-screen color display.
Lightweight and compact, this portable automated pressure calibrator features an accuracy of 0.02% FS and provides a range of -12.5 to 35 psi (-0.86 to 2.5 bar). With a built-in pump, precision pressure sensor, and internal controller, this calibrator comes complete with four channels and a large touch-screen color display.
Discontinued!
This product has been discontinued and is no longer available. There are no replacement options.
We can help you find what you need:
Ideal for common gauge and differential pressure measurements, this portable automated pressure calibrator features an internal module and documenting process functionality.
Features
Applications
| Pressure | |
| Maximum Pressure Range | -12.5 to 35 psi (-0.86 to 2.5 bar) |
| Accuracy | 0.02% FS |
| Stability | <0.005% FS |
| Pressure Type | Differential and gauge |
| Over Range Indication | 1.2 |
| Resolution | 6 digits |
| Measurement Units | Pa, hPa, kPa, mPa, bar, mbar, msi, mmHg at 0°C, cmHg at 32°F (0°C), mHg at 32°F (0°C), inHg at 32°F (0°C), inH2O at 39°F (4°C), mmH2O at 39°F (4°C), cmH2O at 39°F (4°C), mH2O at 39°F (4°C), inH2O at 68°F (20°C), mmH2O at 68°F (20°C), cmH2O at 68°F (20°C), mH2O at 68°F (20°C), inH2O at 154°F (68°C), kgf/cm2, mtorr, torr, lb/ft2, tsi, custom |
| Connection | Hose, 5' (1.5 m), with built-in filter to ¼ BSPF, ¼ NPTF, and M20F adapters |
| Pressure Output Rate | <10 seconds (35 psi/5 ml) |
| Electrical Specifications | |
| mA Measure | Range: ±30 mA Resolution: 0.0001 mA Accuracy: 0.01% RD + 0.005% FS Note: Impedance <10Ω |
| V Measure | Range: ±30 mA Resolution: 0.0001 V Accuracy: 0.01% RD + 0.005% FS Note: Impedance <1Ω |
| mA Source | Range: 24 mA Resolution: 0.001 mA Accuracy: 0.01% RD + 0.005% FS Note: 20 mA at 1K |
| Loop Power Source | Range: 24 V Accuracy: ±1 V Note: 50 mA (maximum loading) |
| Pressure Switch | Open/close Support for mechanical switches and NPN/PNP digital switches |
| Temperature Compensation | 41 to 95°F (5 to 35°C) |
| Temperature Coefficient | <±(0.001% RD + 0.001% FS)/°C outside of 41 to 95°F (5 to 35°C) |
| General Specifications | |
| Channels | Four total: one electrical, one internal pressure, two external pressure (measure only) |
| Enclosure IP Rating | IP52 water and dust proof |
| Battery | Rechargeable Li-Ion battery, typically 10 hours of operation, recharges in less than 4 hours |
| Display | Color 800 x 480 TFT 5" touch screen |
| Communications | USB, WiFi |
| Automation Functions | Switch test, auto step, leak test |
| Misuse Protection | Up to 30 V on any two sockets |
| Multi Lingual Interface | English, German, French, Italian, Spanish, Portuguese, Chinese, Japanese, and Russian |
| Pump Life | >500,000 cycles |
| Temperature | Operation: 32 to 122°F (0 to 50°C), 0 to 90% RH, less than 3000 m Compensated: 32 to 122°F (0 to 50°C) Storage: -4 to 158°F (-20 to 70°C) |
| Vibration and Shock | Vibration: 4 g (20 to 2000 Hz) Shock: 8 g, 1 m drop test |
| Compliance | CE |
| Software | ACal, PCal, Land, LogII |
| Dimensions | 9.3 x 4.3 x 2.8" (235 x 110 x 70 mm) |
| Weight | <4 lbs (<1.8 kg) |
| Pressure | |
| Maximum Pressure Range | -12.5 to 35 psi (-0.86 to 2.5 bar) |
| Accuracy | 0.02% FS |
| Stability | <0.005% FS |
| Pressure Type | Differential and gauge |
| Over Range Indication | 1.2 |
| Resolution | 6 digits |
| Measurement Units | Pa, hPa, kPa, mPa, bar, mbar, msi, mmHg at 0°C, cmHg at 32°F (0°C), mHg at 32°F (0°C), inHg at 32°F (0°C), inH2O at 39°F (4°C), mmH2O at 39°F (4°C), cmH2O at 39°F (4°C), mH2O at 39°F (4°C), inH2O at 68°F (20°C), mmH2O at 68°F (20°C), cmH2O at 68°F (20°C), mH2O at 68°F (20°C), inH2O at 154°F (68°C), kgf/cm2, mtorr, torr, lb/ft2, tsi, custom |
| Connection | Hose, 5' (1.5 m), with built-in filter to ¼ BSPF, ¼ NPTF, and M20F adapters |
| Pressure Output Rate | <10 seconds (35 psi/5 ml) |
| Electrical Specifications | |
| mA Measure | Range: ±30 mA Resolution: 0.0001 mA Accuracy: 0.01% RD + 0.005% FS Note: Impedance <10Ω |
| V Measure | Range: ±30 mA Resolution: 0.0001 V Accuracy: 0.01% RD + 0.005% FS Note: Impedance <1Ω |
| mA Source | Range: 24 mA Resolution: 0.001 mA Accuracy: 0.01% RD + 0.005% FS Note: 20 mA at 1K |
| Loop Power Source | Range: 24 V Accuracy: ±1 V Note: 50 mA (maximum loading) |
| Pressure Switch | Open/close Support for mechanical switches and NPN/PNP digital switches |
| Temperature Compensation | 41 to 95°F (5 to 35°C) |
| Temperature Coefficient | <±(0.001% RD + 0.001% FS)/°C outside of 41 to 95°F (5 to 35°C) |
| General Specifications | |
| Channels | Four total: one electrical, one internal pressure, two external pressure (measure only) |
| Enclosure IP Rating | IP52 water and dust proof |
| Battery | Rechargeable Li-Ion battery, typically 10 hours of operation, recharges in less than 4 hours |
| Display | Color 800 x 480 TFT 5" touch screen |
| Communications | USB, WiFi |
| Automation Functions | Switch test, auto step, leak test |
| Misuse Protection | Up to 30 V on any two sockets |
| Multi Lingual Interface | English, German, French, Italian, Spanish, Portuguese, Chinese, Japanese, and Russian |
| Pump Life | >500,000 cycles |
| Temperature | Operation: 32 to 122°F (0 to 50°C), 0 to 90% RH, less than 3000 m Compensated: 32 to 122°F (0 to 50°C) Storage: -4 to 158°F (-20 to 70°C) |
| Vibration and Shock | Vibration: 4 g (20 to 2000 Hz) Shock: 8 g, 1 m drop test |
| Compliance | CE |
| Software | ACal, PCal, Land, LogII |
| Dimensions | 9.3 x 4.3 x 2.8" (235 x 110 x 70 mm) |
| Weight | <4 lbs (<1.8 kg) |