ACR 01-0025 SmartReader 2

Model: ACR 01-0025 | Order No: 01-0025

ACR 01-0025 SmartReader 2

Model: ACR 01-0025 | Order No: 01-0025

SmartReader 2 data logger with built in temperature sensor, plug in relative humidity sensor and two extra channels.

SmartReader 2 data logger with built in temperature sensor, plug in relative humidity sensor and two extra channels.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

ACR 01-0113 SmartReader Plus 2 Self-Contained Data Logger-

ACR 01-0113 SmartReader Plus 2 Self-Contained Data Logger

Model: ACR 01-0113 | Order No: 01-0113

Monitor and record temperature and relative humidity with this self-contained data logger. Additionally, it features an onboard RH sensor that is temperature compensated, which permits reliable, worry-free RH readings.


ACR SmartReader 2 Four Channel - 32KB, Temperature and Relative Humidity Data Logger

The SmartReader 2 data logger has a built-in temperature sensor, a plug-in relative humidity sensor and comes equipped with two extra channels to connect your choice of either temperature/relative humidity probes or thermistor probe. The RH plug-in sensor is field replaceable guaranteeing you the ability to continuously record.


Features:

  • Four channels
  • Monitor and record temperature and relative humidity
  • Option to monitor remote temperature, RH and/or resistance
  • Use with a variety of different temperature probes (see list above)
  • N.I.S.T. traceable measurements
  • Includes calibration certificate

Applications:

  • Food process verification
  • Pharmaceutical storage
  • Transportation of temperature-sensitive goods
  • Equipment run time
  • HVAC/R system testing and balancing

Specifications:

GENERAL SPECIFICATIONS
Catalog Number 01-0025
Size 107mm x 74mm x 22mm (4.2" x 2.9" x 0.9")
Weight 110 g (3.75 oz)
Case Material Noryl® Plastic
Battery 3.6 volt Lithium, 1 Amp-Hour
Resolution 8-bit (1 part in 256)
Mounting Magnetic backing or locking eyelet
Clock Accuracy ± 2 seconds per day
Sampling Methods Continuous (First-in First-out), Stop When Full (Fill-then-stop)
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
PC Requirements Windows PC with at least one free USB or serial port (depending on interface)
Software Requirements TrendReader® 2 (Compatible with Windows 2000 SP4, XP SP1 and Vista 32 bit)
Memory Size 32 KB (capable of storing up to 32,767 readings)
Sampling Rates User selectable rates from 8 seconds to 5 days in 4-second increments
RH Sensor Capacitive thin polymer film
Response Time Adequate ventilation increases the response time which is approximately 5 minutes in still air
Number of Channels Four (4):
  • One (1) for the internal temperature sensor
  • One (1) for the internal RHsensor
  • The remaining two channels are reserved for an optional remoteEH-020A probe [temperature and RH probe])
Environmental Conditions Like all relative humidity sensors, when exposed to contaminants and/or extreme environmental conditions, accuracy degradation could result. For maximum long-term stability, sensor should not be exposed or subjected to organic solvents, corrosive agents (strong acids, SO2, H2SO4, CI2, HCl, H2S, etc.), and strong bases (compounds with PH greater than 7). Dust settling on the sensor surface will not affect sensor performance except possibly to decrease the speed of response.
SENSOR SPECIFICATIONS
Internal Temperature Sensor
Type NTC Thermistor - 10,000 Ohm @ 25°C (77°F)
Range -40°C to 70°C (-40°F to 158°F)
Accuracy ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F)
Resolution 0.4°C (0.7°F) @ 25°C; better than 1°C (1.8°F) between -25°C and 70°C
(-13°F and 158°F); better than 2.0°C (3.6°F) between -40°C and -25°C
(-40°F and -13°F)
Internal Relative Humidity Sensor
Type Capactive thin polymer film
Range 0 to 95% RH (non-condensing)
Accuracy ±4% RH from 10 to 90% RH (-20 to 40°C [-4 to 104°F])
Resolution Better than 0.4% RH between 25 and 60% RH @ 25°C (77°F)
Click here for complete specifications on the ACR ACR 01-0025

What's included with the ACR ACR 01-0025

  • ACR 01-0025 SmartReader 2

Click on a category to view a selection of compatible accessories with the ACR 01-0025 SmartReader 2.

ACR 01-0057 Weatherproof Logger Box ACR 01-0057
NEMA 4X clear-faced weatherproof box for all ACR loggers, Size: 18 x 13 x 10cm (7 x 5 x 4").




ACR 35-0025 Pipe Surface Thermal Probe - General Purpose ACR 35-0025
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 35-0020 Skin Surface Thermal Probe - Human Temperature ACR 35-0020
Stainless steel, 1/3 X 9/64in probe. Thermistor type. Range: 20 to 40°C (68 to 104°F). Length: 5ft (1.5 meters).




ACR 35-0003 Thermal Probe - Oven Temperature ACR 35-0003
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: 70 to 255°C (155 to 490°F). Length: 20ft (6 meters).




ACR 35-0002 Therm-Probe - GP Tip - 80C - SR SRP ACR 35-0002
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: 10 to 170°C (50 to 335°F). Length: 20ft (6 meters).




ACR 35-0001 Thermal Probe - General Purpose Temperature ACR 35-0001
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 29-0013 Terminal Block Strain Relief ACR 29-0013
Strain relief for sensors attached to SmartReader/SmartReader Plus 11-pin terminal blocks.




ACR 01-0088 Logger-PC Interface Cable, 4' ACR 01-0088
Connect the SmartReader Plus data logger to PC computer through a USB port with this interface cable which measures 4' (1.22 m). In addition, this interface cable has a 0.138" (3.5 mm) stereo jack connection.




ACR 01-0077 Logger-PC Interface Cable (IC-101) ACR 01-0077
9-pin PC serial port to logger interface cable. Compatible with SmartReader and SmartReader Plus loggers.




ACR 29-0004 Terminal Block - 11 Pin ACR 29-0004
11-pin female teminal block for SmartReader/SmartReader Plus sensor inputs.




Ask a question about ACR 01-0025 SmartReader 2

Customer Reviews for the ACR ACR 01-0025

ACR SmartReader 2 Four Channel - 32KB, Temperature and Relative Humidity Data Logger

The SmartReader 2 data logger has a built-in temperature sensor, a plug-in relative humidity sensor and comes equipped with two extra channels to connect your choice of either temperature/relative humidity probes or thermistor probe. The RH plug-in sensor is field replaceable guaranteeing you the ability to continuously record.


Features:

  • Four channels
  • Monitor and record temperature and relative humidity
  • Option to monitor remote temperature, RH and/or resistance
  • Use with a variety of different temperature probes (see list above)
  • N.I.S.T. traceable measurements
  • Includes calibration certificate

Applications:

  • Food process verification
  • Pharmaceutical storage
  • Transportation of temperature-sensitive goods
  • Equipment run time
  • HVAC/R system testing and balancing

Specifications:

GENERAL SPECIFICATIONS
Catalog Number 01-0025
Size 107mm x 74mm x 22mm (4.2" x 2.9" x 0.9")
Weight 110 g (3.75 oz)
Case Material Noryl® Plastic
Battery 3.6 volt Lithium, 1 Amp-Hour
Resolution 8-bit (1 part in 256)
Mounting Magnetic backing or locking eyelet
Clock Accuracy ± 2 seconds per day
Sampling Methods Continuous (First-in First-out), Stop When Full (Fill-then-stop)
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
PC Requirements Windows PC with at least one free USB or serial port (depending on interface)
Software Requirements TrendReader® 2 (Compatible with Windows 2000 SP4, XP SP1 and Vista 32 bit)
Memory Size 32 KB (capable of storing up to 32,767 readings)
Sampling Rates User selectable rates from 8 seconds to 5 days in 4-second increments
RH Sensor Capacitive thin polymer film
Response Time Adequate ventilation increases the response time which is approximately 5 minutes in still air
Number of Channels Four (4):
  • One (1) for the internal temperature sensor
  • One (1) for the internal RHsensor
  • The remaining two channels are reserved for an optional remoteEH-020A probe [temperature and RH probe])
Environmental Conditions Like all relative humidity sensors, when exposed to contaminants and/or extreme environmental conditions, accuracy degradation could result. For maximum long-term stability, sensor should not be exposed or subjected to organic solvents, corrosive agents (strong acids, SO2, H2SO4, CI2, HCl, H2S, etc.), and strong bases (compounds with PH greater than 7). Dust settling on the sensor surface will not affect sensor performance except possibly to decrease the speed of response.
SENSOR SPECIFICATIONS
Internal Temperature Sensor
Type NTC Thermistor - 10,000 Ohm @ 25°C (77°F)
Range -40°C to 70°C (-40°F to 158°F)
Accuracy ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F)
Resolution 0.4°C (0.7°F) @ 25°C; better than 1°C (1.8°F) between -25°C and 70°C
(-13°F and 158°F); better than 2.0°C (3.6°F) between -40°C and -25°C
(-40°F and -13°F)
Internal Relative Humidity Sensor
Type Capactive thin polymer film
Range 0 to 95% RH (non-condensing)
Accuracy ±4% RH from 10 to 90% RH (-20 to 40°C [-4 to 104°F])
Resolution Better than 0.4% RH between 25 and 60% RH @ 25°C (77°F)
Click here for complete specifications on the ACR ACR 01-0025

What's included with the ACR ACR 01-0025

  • ACR 01-0025 SmartReader 2

Click on a category to view a selection of compatible accessories with the ACR 01-0025 SmartReader 2.

ACR 01-0057 Weatherproof Logger Box ACR 01-0057
NEMA 4X clear-faced weatherproof box for all ACR loggers, Size: 18 x 13 x 10cm (7 x 5 x 4").




ACR 35-0025 Pipe Surface Thermal Probe - General Purpose ACR 35-0025
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 35-0020 Skin Surface Thermal Probe - Human Temperature ACR 35-0020
Stainless steel, 1/3 X 9/64in probe. Thermistor type. Range: 20 to 40°C (68 to 104°F). Length: 5ft (1.5 meters).




ACR 35-0003 Thermal Probe - Oven Temperature ACR 35-0003
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: 70 to 255°C (155 to 490°F). Length: 20ft (6 meters).




ACR 35-0002 Therm-Probe - GP Tip - 80C - SR SRP ACR 35-0002
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: 10 to 170°C (50 to 335°F). Length: 20ft (6 meters).




ACR 35-0001 Thermal Probe - General Purpose Temperature ACR 35-0001
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 29-0013 Terminal Block Strain Relief ACR 29-0013
Strain relief for sensors attached to SmartReader/SmartReader Plus 11-pin terminal blocks.




ACR 01-0088 Logger-PC Interface Cable, 4' ACR 01-0088
Connect the SmartReader Plus data logger to PC computer through a USB port with this interface cable which measures 4' (1.22 m). In addition, this interface cable has a 0.138" (3.5 mm) stereo jack connection.




ACR 01-0077 Logger-PC Interface Cable (IC-101) ACR 01-0077
9-pin PC serial port to logger interface cable. Compatible with SmartReader and SmartReader Plus loggers.




ACR 29-0004 Terminal Block - 11 Pin ACR 29-0004
11-pin female teminal block for SmartReader/SmartReader Plus sensor inputs.




Ask a question about ACR 01-0025 SmartReader 2

Customer Reviews for the ACR ACR 01-0025