SmartReader 2 data logger with built in temperature sensor, plug in relative humidity sensor and two extra channels.
SmartReader 2 data logger with built in temperature sensor, plug in relative humidity sensor and two extra channels.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
The SmartReader 2 data logger has a built-in temperature sensor, a plug-in relative humidity sensor and comes equipped with two extra channels to connect your choice of either temperature/relative humidity probes or thermistor probe. The RH plug-in sensor is field replaceable guaranteeing you the ability to continuously record.
| GENERAL SPECIFICATIONS | |
| Catalog Number | 01-0025 |
| Size | 107mm x 74mm x 22mm (4.2" x 2.9" x 0.9") |
| Weight | 110 g (3.75 oz) |
| Case Material | Noryl® Plastic |
| Battery | 3.6 volt Lithium, 1 Amp-Hour |
| Resolution | 8-bit (1 part in 256) |
| Mounting | Magnetic backing or locking eyelet |
| Clock Accuracy | ± 2 seconds per day |
| Sampling Methods | Continuous (First-in First-out), Stop When Full (Fill-then-stop) |
| Operating Limits | -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing) |
| PC Requirements | Windows PC with at least one free USB or serial port (depending on interface) |
| Software Requirements | TrendReader® 2 (Compatible with Windows 2000 SP4, XP SP1 and Vista 32 bit) |
| Memory Size | 32 KB (capable of storing up to 32,767 readings) |
| Sampling Rates | User selectable rates from 8 seconds to 5 days in 4-second increments |
| RH Sensor | Capacitive thin polymer film |
| Response Time | Adequate ventilation increases the response time which is approximately 5 minutes in still air |
| Number of Channels |
Four (4):
|
| Environmental Conditions | Like all relative humidity sensors, when exposed to contaminants and/or extreme environmental conditions, accuracy degradation could result. For maximum long-term stability, sensor should not be exposed or subjected to organic solvents, corrosive agents (strong acids, SO2, H2SO4, CI2, HCl, H2S, etc.), and strong bases (compounds with PH greater than 7). Dust settling on the sensor surface will not affect sensor performance except possibly to decrease the speed of response. |
| SENSOR SPECIFICATIONS | |
| Internal Temperature Sensor | |
| Type | NTC Thermistor - 10,000 Ohm @ 25°C (77°F) |
| Range | -40°C to 70°C (-40°F to 158°F) |
| Accuracy | ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F) |
| Resolution |
0.4°C (0.7°F) @ 25°C; better than 1°C (1.8°F) between -25°C and 70°C (-13°F and 158°F); better than 2.0°C (3.6°F) between -40°C and -25°C (-40°F and -13°F) |
| Internal Relative Humidity Sensor | |
| Type | Capactive thin polymer film |
| Range | 0 to 95% RH (non-condensing) |
| Accuracy | ±4% RH from 10 to 90% RH (-20 to 40°C [-4 to 104°F]) |
| Resolution | Better than 0.4% RH between 25 and 60% RH @ 25°C (77°F) |
Click on a category to view a selection of compatible accessories with the ACR 01-0025 SmartReader 2.
| GENERAL SPECIFICATIONS | |
| Catalog Number | 01-0025 |
| Size | 107mm x 74mm x 22mm (4.2" x 2.9" x 0.9") |
| Weight | 110 g (3.75 oz) |
| Case Material | Noryl® Plastic |
| Battery | 3.6 volt Lithium, 1 Amp-Hour |
| Resolution | 8-bit (1 part in 256) |
| Mounting | Magnetic backing or locking eyelet |
| Clock Accuracy | ± 2 seconds per day |
| Sampling Methods | Continuous (First-in First-out), Stop When Full (Fill-then-stop) |
| Operating Limits | -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing) |
| PC Requirements | Windows PC with at least one free USB or serial port (depending on interface) |
| Software Requirements | TrendReader® 2 (Compatible with Windows 2000 SP4, XP SP1 and Vista 32 bit) |
| Memory Size | 32 KB (capable of storing up to 32,767 readings) |
| Sampling Rates | User selectable rates from 8 seconds to 5 days in 4-second increments |
| RH Sensor | Capacitive thin polymer film |
| Response Time | Adequate ventilation increases the response time which is approximately 5 minutes in still air |
| Number of Channels |
Four (4):
|
| Environmental Conditions | Like all relative humidity sensors, when exposed to contaminants and/or extreme environmental conditions, accuracy degradation could result. For maximum long-term stability, sensor should not be exposed or subjected to organic solvents, corrosive agents (strong acids, SO2, H2SO4, CI2, HCl, H2S, etc.), and strong bases (compounds with PH greater than 7). Dust settling on the sensor surface will not affect sensor performance except possibly to decrease the speed of response. |
| SENSOR SPECIFICATIONS | |
| Internal Temperature Sensor | |
| Type | NTC Thermistor - 10,000 Ohm @ 25°C (77°F) |
| Range | -40°C to 70°C (-40°F to 158°F) |
| Accuracy | ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F) |
| Resolution |
0.4°C (0.7°F) @ 25°C; better than 1°C (1.8°F) between -25°C and 70°C (-13°F and 158°F); better than 2.0°C (3.6°F) between -40°C and -25°C (-40°F and -13°F) |
| Internal Relative Humidity Sensor | |
| Type | Capactive thin polymer film |
| Range | 0 to 95% RH (non-condensing) |
| Accuracy | ±4% RH from 10 to 90% RH (-20 to 40°C [-4 to 104°F]) |
| Resolution | Better than 0.4% RH between 25 and 60% RH @ 25°C (77°F) |