ACI A Series CO2 Room Carbon Dioxide Transmitter, 0 to 2000 ppm, 0 to 10 V DC

Model: A/CO2-R2 | Order No: 144220/A

ACI A Series CO2 Room Carbon Dioxide Transmitter, 0 to 2000 ppm, 0 to 10 V DC

Model: A/CO2-R2 | Order No: 144220/A

Made for demand control ventilation, this wall-mounted carbon dioxide transmitter measures 0 to 2000 ppm by single beam NDIR. In addition, outputs are 0 to 10 V DC and 4 to 20 mA, with 0-5 V DC field selectable on integral dip switches. Automatic baseline correction removes manual calibration in schools, offices and auditoriums.

Made for demand control ventilation, this wall-mounted carbon dioxide transmitter measures 0 to 2000 ppm by single beam NDIR. In addition, outputs are 0 to 10 V DC and 4 to 20 mA, with 0-5 V DC field selectable on integral dip switches. Automatic baseline correction removes manual calibration in schools, offices and auditoriums.

Sale Price $210.33 USD
Regular Price $401.00 USD
Availability 2 to 3 Weeks
Quantity

ACI A/CO2-R2 Offers

The ACI Carbon Dioxide Room Series (A/CO2-R2) monitors the carbon dioxide (CO2) levels in commercial, school, and office-type environments. The concentration of CO2 is a strong indication of the overall indoor air quality. The A/CO2 Series is based on a single beam, non-dispersive infrared technology and is a cost-efficient solution for measuring carbon dioxide levels for building climate control.

In addition, ABC software eliminates the need for manual calibration. Carbon Dioxide concentration is measured up to 2,000 ppm and is converted into proportional analog outputs. The factory default outputs are 0-10 V DC (Output 1) and 4-20 mA (Output 2), whereas 0-5 V DC is field selectable via integral dip switches.

Thermistor temperature outputs, along with setpoint and override, are available as options for this configuration as well. Please see the order grid for the available sensor options. The A/CO2-R2 Series provides data which can be used in conjunction with a Building Automation System or Demand Control Ventilation to decrease energy consumption while creating a healthier indoor climate.

Applications

  • Demand control ventilation in classrooms and offices
  • Wall-mounted indoor air quality monitoring in occupied spaces
  • Auditorium and gymnasium ventilation control
  • Shopping mall and theatre air quality monitoring
  • Zone CO2 monitoring for building automation systems

ACI A/CO2-R2 Specifications

Sensing Method Technology: Single beam infrared sensing technology (NDIR)
Method: Diffusion
Configuration Room
Measurement Default range: 0 to 2000 ppm
Extended ranges: Up to 10,000 ppm (factory set)
Accuracy: ±40 ppm and ±3% of reading (at 15 to 35°C; 20 to 70% RH and 101.3 kPa)
Extended range accuracy: ±30 ppm and ±5% of reading
Pressure dependence: +1.6% reading per kPa (deviation from standard pressure 101.3 kPa)
Response time: ≤2 minutes, diffusion
Warm-up time: <1 Minute (at full specs <15 minutes)
Temperature output range: Various (See Ordering Grid)
Temperature accuracy: ±1°F (±0.6°C)
Sensor Life and Calibration Sensor life: >15 years (typical)
Calibration: ABC algorithm (Automatic Baseline Correction)
Mounting Mounting height: 4 to 6' (1.2 to 1.8 m)
Sensor coverage area: 7,500 sq ft maximum
Output CO2 output signal: Output 1: 0-5 V DC or 0-10 V DC (Default); Output 2: 4-20 mA (500 Ohm load maximum)
Fail safe: Polarity protected
Power Supply Supply voltage: 24 V AC ±20%, 50/60 Hz (half-wave rectifier) | 16.5 to 40 V DC maximum
Power consumption: 3 VA for 24 V AC, 3 W for 24 V DC (peak); <0.9 W (average)
Connections Type: Screw terminal blocks
Wire size: 16 AWG (1.31 mm²) to 26 AWG (0.129 mm²)
Terminal block torque rating: 0.5 Nm (minimum); 0.6 Nm (maximum)
Enclosure ABS, Plastic, White, UL94-HB
Operating Temperature Range 32 to 122°F (0 to 50°C)
Operating Humidity Range 0 to 95%, non-condensing
Agency Approvals EMC Directive 2014/30/EC | RoHS Directive 2011/65/EU
Dimensions 4.50 x 2.75 x 1.12" (114.30 x 69.85 x 28.45 mm)
Weight 0.23 lbs (0.104 kg)
Click here for complete specifications on the ACI A/CO2-R2

What's included with the ACI A/CO2-R2

  • Sensor
  • Limited Five-Year Warranty

Ask a question about ACI A Series CO2 Room Carbon Dioxide Transmitter, 0 to 2000 ppm, 0 to 10 V DC

Customer Reviews for the ACI A/CO2-R2

ACI A/CO2-R2 Offers

The ACI Carbon Dioxide Room Series (A/CO2-R2) monitors the carbon dioxide (CO2) levels in commercial, school, and office-type environments. The concentration of CO2 is a strong indication of the overall indoor air quality. The A/CO2 Series is based on a single beam, non-dispersive infrared technology and is a cost-efficient solution for measuring carbon dioxide levels for building climate control.

In addition, ABC software eliminates the need for manual calibration. Carbon Dioxide concentration is measured up to 2,000 ppm and is converted into proportional analog outputs. The factory default outputs are 0-10 V DC (Output 1) and 4-20 mA (Output 2), whereas 0-5 V DC is field selectable via integral dip switches.

Thermistor temperature outputs, along with setpoint and override, are available as options for this configuration as well. Please see the order grid for the available sensor options. The A/CO2-R2 Series provides data which can be used in conjunction with a Building Automation System or Demand Control Ventilation to decrease energy consumption while creating a healthier indoor climate.

Applications

  • Demand control ventilation in classrooms and offices
  • Wall-mounted indoor air quality monitoring in occupied spaces
  • Auditorium and gymnasium ventilation control
  • Shopping mall and theatre air quality monitoring
  • Zone CO2 monitoring for building automation systems

ACI A/CO2-R2 Specifications

Sensing Method Technology: Single beam infrared sensing technology (NDIR)
Method: Diffusion
Configuration Room
Measurement Default range: 0 to 2000 ppm
Extended ranges: Up to 10,000 ppm (factory set)
Accuracy: ±40 ppm and ±3% of reading (at 15 to 35°C; 20 to 70% RH and 101.3 kPa)
Extended range accuracy: ±30 ppm and ±5% of reading
Pressure dependence: +1.6% reading per kPa (deviation from standard pressure 101.3 kPa)
Response time: ≤2 minutes, diffusion
Warm-up time: <1 Minute (at full specs <15 minutes)
Temperature output range: Various (See Ordering Grid)
Temperature accuracy: ±1°F (±0.6°C)
Sensor Life and Calibration Sensor life: >15 years (typical)
Calibration: ABC algorithm (Automatic Baseline Correction)
Mounting Mounting height: 4 to 6' (1.2 to 1.8 m)
Sensor coverage area: 7,500 sq ft maximum
Output CO2 output signal: Output 1: 0-5 V DC or 0-10 V DC (Default); Output 2: 4-20 mA (500 Ohm load maximum)
Fail safe: Polarity protected
Power Supply Supply voltage: 24 V AC ±20%, 50/60 Hz (half-wave rectifier) | 16.5 to 40 V DC maximum
Power consumption: 3 VA for 24 V AC, 3 W for 24 V DC (peak); <0.9 W (average)
Connections Type: Screw terminal blocks
Wire size: 16 AWG (1.31 mm²) to 26 AWG (0.129 mm²)
Terminal block torque rating: 0.5 Nm (minimum); 0.6 Nm (maximum)
Enclosure ABS, Plastic, White, UL94-HB
Operating Temperature Range 32 to 122°F (0 to 50°C)
Operating Humidity Range 0 to 95%, non-condensing
Agency Approvals EMC Directive 2014/30/EC | RoHS Directive 2011/65/EU
Dimensions 4.50 x 2.75 x 1.12" (114.30 x 69.85 x 28.45 mm)
Weight 0.23 lbs (0.104 kg)
Click here for complete specifications on the ACI A/CO2-R2

What's included with the ACI A/CO2-R2

  • Sensor
  • Limited Five-Year Warranty