Mounted through a duct wall, this humidity transmitter reads relative humidity in the air stream to ±3% accuracy with a thermoset polymer capacitive element protected by a factory-fitted hydrophobic filter. Zero, span and full-scale test positions let a technician confirm the loop is live and correctly wired before leaving site.
Mounted through a duct wall, this humidity transmitter reads relative humidity in the air stream to ±3% accuracy with a thermoset polymer capacitive element protected by a factory-fitted hydrophobic filter. Zero, span and full-scale test positions let a technician confirm the loop is live and correctly wired before leaving site.
The ACI Relative Humidity Duct utilizes a thermoset polymer capacitive sensing element with a factory fitted hydrophobic filter to improve its moisture resistance. The sensing elements multilayer construction also provides excellent resistance in applications where dust, dirt, oils and common environmental chemicals are found. The RH duct sensors include on board DIP switches which allow the user to select the desired output signal and can be powered by AC or DC power sources. Each unit also contains 0%, 50%, and 100% test options to verify that the transmitter is both working and wired properly.
Features
Applications
| RH Measurement Range | 0 to 100% |
| RH Accuracy @ 77°F (25°C) | ± 1% over 20% RH Range between 20 to 90% | ± 2%, or 3% from 10 to 95% |
| RH Stability | Repeatability | Sensitivity | Less than 2% drift / 5 years | 0.5% RH | 0.1% RH |
| RH Output Load Resistance | 4 to 20 mA: 700 Ohms maximum | 0 to 5 V DC or 0 to 10 V DC: 4K Ohms Minimum |
| RH Output Signal | 2-wire: 4 to 20 mA (Factory Default) | 3-wire: 0 to 5 or 0 to 10 V DC and 4 to 20 mA (Field Selectable) |
| RH Response Time (T63) | 20 Seconds Typical |
| RH Transmitter Stabilization Time | 30 Minutes (Recommended time before doing accuracy verification) |
| RH Supply Current (VA) | Voltage Output: 8 mA maximum (0.32 VA) | Current Output: 24 mA maximum (0.83 VA) |
| RH Supply Voltage (Reverse Polarity Protected) | 0 to 5 V DC: 12 to 40 V DC / 18 to 28 V AC | 0 to 10 V DC: 18 to 40 V DC / 18 to 28 V AC |
| RH Sensor Type | Capacitive with Hydrophobic Filter |
| RH Connections | Wire Size | Screw Terminal Blocks (Polarity Sensitive) | 16 (1.31 mm2) to 26 AWG (0.129 mm2) |
| RH Terminal Block Torque Rating | 4.43 to 5.31 lb-in (0.5 to 0.6 Nm) |
| Operating RH Range | 0 to 95% RH, non-condensing (Conformally Coated PCB's) |
| Operating Temperature Range | -40 to 140°F (-40 to 60°C) |
| Storage Temperature Range | -40 to 149°F (-40 to 65°C) |
| Agency Approvals | UKCA, CE, RoHS, WEEE |
| RH Measurement Range | 0 to 100% |
| RH Accuracy @ 77°F (25°C) | ± 1% over 20% RH Range between 20 to 90% | ± 2%, or 3% from 10 to 95% |
| RH Stability | Repeatability | Sensitivity | Less than 2% drift / 5 years | 0.5% RH | 0.1% RH |
| RH Output Load Resistance | 4 to 20 mA: 700 Ohms maximum | 0 to 5 V DC or 0 to 10 V DC: 4K Ohms Minimum |
| RH Output Signal | 2-wire: 4 to 20 mA (Factory Default) | 3-wire: 0 to 5 or 0 to 10 V DC and 4 to 20 mA (Field Selectable) |
| RH Response Time (T63) | 20 Seconds Typical |
| RH Transmitter Stabilization Time | 30 Minutes (Recommended time before doing accuracy verification) |
| RH Supply Current (VA) | Voltage Output: 8 mA maximum (0.32 VA) | Current Output: 24 mA maximum (0.83 VA) |
| RH Supply Voltage (Reverse Polarity Protected) | 0 to 5 V DC: 12 to 40 V DC / 18 to 28 V AC | 0 to 10 V DC: 18 to 40 V DC / 18 to 28 V AC |
| RH Sensor Type | Capacitive with Hydrophobic Filter |
| RH Connections | Wire Size | Screw Terminal Blocks (Polarity Sensitive) | 16 (1.31 mm2) to 26 AWG (0.129 mm2) |
| RH Terminal Block Torque Rating | 4.43 to 5.31 lb-in (0.5 to 0.6 Nm) |
| Operating RH Range | 0 to 95% RH, non-condensing (Conformally Coated PCB's) |
| Operating Temperature Range | -40 to 140°F (-40 to 60°C) |
| Storage Temperature Range | -40 to 149°F (-40 to 65°C) |
| Agency Approvals | UKCA, CE, RoHS, WEEE |