Specially developed for high-precision submetering and real-time event capture, this advanced power quality meter boasts revenue-grade accuracy and instantaneous power-quality event logging. In addition, this meter comes with a display, a 333 mV or Rogowski coil input, and a 100 to 415 V AC or 100 to 300 V DC power supply.
Specially developed for high-precision submetering and real-time event capture, this advanced power quality meter boasts revenue-grade accuracy and instantaneous power-quality event logging. In addition, this meter comes with a display, a 333 mV or Rogowski coil input, and a 100 to 415 V AC or 100 to 300 V DC power supply.
The Acuvim 3 advanced power quality meters are engineered to provide high-precision power quality metering plus revenue grade, IEC Class 0.1S/ANSI C12.20 Class 0.1 (active energy) four-quadrant power monitoring. With support for synchrophasor applications, it can record real-time power quality disturbances, like dips, swells interruptions, unbalance, flicker, and transients as well as capture critical waveforms triggered by sub-second power quality events. Its enhanced Fast Log capture feature can generate and send reports, providing critical information to mitigate the impact of damaging power quality issues. Compact and robust, this advanced power quality meter features a wide range of flexible communication protocols plus an easy-to-use interface with advanced user management and security.
Features
Power quality metering
IEC 61000-4-30 Class-A compliant measurement for:
Power quality reporting and analysis
Power quality event detection for:
Power quality event to trigger email notification, or DO/RO
Up to 65,535 power quality event logs in circular buffer
Waveform Capture
Fast Log Capture
Reporting
Advanced power and energy metering
IEC 62053-22 Class 0.1S active energy measurements
IEC 62053-24 Class 0.5S reactive energy measurements
Import/export/net/total and Four-Quadrant energy measurements
Time of Use (TOU) support:
Communication protocols
Applications
General | |
Voltage Accuracy | 0.1% reading, 10 to 400 VLN, 690 VLL |
Current Accuracy | 0.1% reading: 1 A nominal: 10 mA to 2 A 5 A nominal: 50 mA to 10 A |
Frequency Accuracy | 1 mHz, 40 to 70 Hz |
Active Energy Accuracy | IEC 62053-22 Class 0.1S ANSI C12.20 Class 0.1 |
Power Quality | IEC 6100-4-30 Class A, testing according to IEC 62586-2 (2017) |
Safety | IEC/UL 61010-1:2010 IEC/UL 61010-2-030:2010 Overvoltage Category III Measurement Category III |
Measurements | |
Voltage RMS | IEC 61557-12 Class 0.1, 10 to 400 VLN, 690 VLL |
Current RMS | IEC 61557-12 Class 0.1 1 A nominal: 10 mA to 2 A 5 A nominal: 50 mA to 10 A |
Frequency | 1 mHz accuracy, 40 to 70 Hz, exceeds requirement of IEC 61557-12 Class 0.02 |
Power and Power Factor (for each phase and system) | Active power: IEC 61557-12 Class 0.1 ReActive power: Exceeds requirement of IEC 61557-12 Class 1 Apparent power: IEC 61557-12 Class 0.2 Power factor: Exceeds requirement of IEC 61557-12 Class 0.5 |
Fundamental Measurements | Line to neutral voltage RMS Line to line voltage RMS Line current RMS Active power Reactive power Apparent power Power factor |
maximumimum/Minimum | maximumimum/minimum of RMS Power and power factors Fundamental measurements records with timestamp |
Demand | Algorithms: Block and rolling window Log peak demand and peak demand time Current demand for each phase and system Per phase and system active power demand: Import/export/net/total Four-quadrant Per phase and system reactive power demand: Import/export/net/total Four-quadrant Per phase and system apparent power demand: Total Four-quadrant |
Energy (per phase and system) | Active energy, IEC 62053-22 Class 0.1S: Import/export/net/total Four-quadrant Reactive energy, IEC 62053-24 Class 0.5S: Import/export/net/total Four-quadrant Per phase and system Apparent energy, IEC 61557-12 Class 0.2: Total Four-quadrant |
TOU Energy and Demand | For system import active energy, import reactive energy, and apparent energy: Up to 8 tariff rates Record maximumimum power demand of billing period Record current and up to 12 historic billing periods |
Power Quality Measurements | Positive/negative/zero sequence for current and voltage Phase angle for current and voltage Harmonics magnitude and angle for current and voltage, up to 127th Flicker |
Communications | |
Communication Interfaces | 2 x Ethernet ports (100BASE-TX) with IEEE1588 support: RJ45 connector, CAT5/5e/6/6a cable 1 Wi-Fi (802.11 b/g/n 2.4 GHz) 1 RS485 port: Baud rates of 2400 to 115,200, pluggable screw terminal connector 1 USB-C port 1 IRIG-B port |
Time Synchronization | NTP PTP IRIG-B |
Serial Port Protocols | Modbus RTU |
Web Server | HTTP/HTTPS |
Ethernet Port Protocols | IPv4, IPv6, DHCP, DNS Modbus TCP, DNP3 TCP, IEC 61850, SNMP, BACnet/IP, PMU (IEEE C37.118) Data post with HTTP(s)/FTP/SFTP/SMPT/SMPT E-mail File download with HTTP(s)/SFPT |
Electrical Characteristics | |
Power Supply | 50/60 Hz, 100 to 415 V AC/100 to 300 V DC |
AC Voltage Inputs | Accuracy range: 10 to 400 VLN, 690 VLL Pickup: 5 V Overload: 1500 V AC continuously; 2500 V AC, 50/60 Hz 1 minute Measurement category: III Frequency range: 40 to 70 Hz (50/60 Hz nominal) |
AC Current Inputs | Nominal current: 1 or 5 A Accuracy range: 1 A nominal: 10 mA to 2 A 5 A nominal: 50 mA to 10 A Pickup: 1 A nominal: 0.5 mA 5 A nominal: 2.5 mA Surge: 20 A continuous, 50 A at 10 second/hour, 500 A at 1 second/hour |
Input and Output (meter base) | 4 digital inputs: Input voltage range: 20 to 150 V AC/DC Input current (maximum): 2.5 mA Start voltage: 15 V Stop voltage: 5 V Pulse frequency (maximum): 100 Hz, 50% duty ratio (5ms ON and 5ms OFF) SOE resolution: 2ms 1 digital output: Dry contact Voltage range: 30 V DC Load current: 60 mA (maximum) Output frequency: 50 Hz, 50% duty ratio (20ms ON, 20ms OFF) Isolation voltage: 5000 V AC |
I/O Modules (up to 3, sold separately) | Digital input: Input voltage range 20 to 160 V AC/DC Input current (maximum) 2 mA Start voltage 15 V Stop voltage 5 V Pulse frequency (maximum) 100 Hz, 50% duty ratio SOE resolution 2ms Digital output (DO) (Photo-MOS): Voltage range 0 to 250 V AC/DC Load current 100 mA(maximum) Output frequency 25 Hz, 50% duty ratio Isolation voltage 2500 V AC Relay output (RO): Switching voltage (maximum) 250 V AC, 30 V DC Load current 5 A(R), 2 A(L) Set time 10ms (maximum) Contact resistance 30 mΩ (maximum) Isolation voltage 2500 V AC Analog output (AO): Output range 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (optional) Accuracy 0.5% Temperature drift 50 ppm/°C typical Isolation voltage 500 V DC Open circuit voltage 15 V Analog input (AI): Input range 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (optional) Accuracy 0.2% Temperature drift 50 ppm/°C typical Isolation voltage 500 V DC |
Mechanical Characteristics | |
Outlines Standard | DIN 43700, ANSI C39.1 Round or square, 3.6 x 3.6" (92 x 92 mm) |
IP Degree of Protection | IP 54: panel mount and touchscreen display, front IP 30: panel mount rear, DIN rail mount, I/O modules |
Environmental Conditions | |
Temperature | Operating: -13 to 158°F (-25 to 70°C) Storage: -40 to 158°F (-40 to 70°C) |
Pressure | Normal |
Humidity | 5 to 95% RH non-condensing |
Altitude | 9842.5' (3000 m) |
Pollution Degree | 2 |
Location/Mounting | Indoor use only |
Electromagnetic Compatibility | |
Immunity to Fast Transients | IEC 61000-4-4: Power, input/output, voltage/current circuits: ±4 kV (5 kHz) Communication: ±4 kV (5 kHz) |
Immunity to Ring Waves | IEC 61000-4-12: Power, input/output, voltage/current circuits: 2.5 kV Communication: 2.5 kV |
Immunity to Electrostatic Discharge | IEC 61000-4-2: Contact discharge: ±4 kV Air discharge: ±8 kV |
Immunity to Voltage Dips and Interruptions | IEC 61000-4-11: 70%, 20 ms 0%, 100 ms |
Immunity to Power Frequency and Magnetic Fields | IEC 61000-4-8: 100 A/m, 1 minute 1000 A/m, 3 seconds |
Immunity to Surges | IEC 61000-4-5: Power, voltage/current circuits: ±4 kV Input/output: 2 kV Communication: 2 kV |
Immunity to Radiated Fields | IEC 61000-4-3: 80 to 1000 MHz: 10 V/m 1 to 2.7 GHz: 3 V/m 2.7 to 6.0 GHz: 1 V/m |
Immunity to Conducted Disturbances | IEC 61000-4-6: 150 kHz to 80 MHz: 10 V |
Immunity to Power Frequency Disturbances | IEC 61000-4-16: 30 V: 1 minute 300 V: 1 s |
Immunity to Damped Oscillatory Wave | IEC 61000-4-18: AC: 2.5 kV (common mode, 1 MHz) 1 kV (differential mode, 1 MHz) 1 kV (differential mode, 10 MHz) DC: 2.5 kV (common mode, 1 MHz) 1 kV (differential mode, 1 MHz) 1 kV (differential mode, 10 MHz) IO: 2.5 kV (common mode, 1 MHz) 1 kV (differential mode, 1 MHz) |
Radiated Emissions | CISPR 32 Class B |
Click on a category to view a selection of compatible accessories with the Accuenergy Acuvim 3 Series Advanced Power Quality Meter with panel mount and display, 333 mV, AC/DC.
General | |
Voltage Accuracy | 0.1% reading, 10 to 400 VLN, 690 VLL |
Current Accuracy | 0.1% reading: 1 A nominal: 10 mA to 2 A 5 A nominal: 50 mA to 10 A |
Frequency Accuracy | 1 mHz, 40 to 70 Hz |
Active Energy Accuracy | IEC 62053-22 Class 0.1S ANSI C12.20 Class 0.1 |
Power Quality | IEC 6100-4-30 Class A, testing according to IEC 62586-2 (2017) |
Safety | IEC/UL 61010-1:2010 IEC/UL 61010-2-030:2010 Overvoltage Category III Measurement Category III |
Measurements | |
Voltage RMS | IEC 61557-12 Class 0.1, 10 to 400 VLN, 690 VLL |
Current RMS | IEC 61557-12 Class 0.1 1 A nominal: 10 mA to 2 A 5 A nominal: 50 mA to 10 A |
Frequency | 1 mHz accuracy, 40 to 70 Hz, exceeds requirement of IEC 61557-12 Class 0.02 |
Power and Power Factor (for each phase and system) | Active power: IEC 61557-12 Class 0.1 ReActive power: Exceeds requirement of IEC 61557-12 Class 1 Apparent power: IEC 61557-12 Class 0.2 Power factor: Exceeds requirement of IEC 61557-12 Class 0.5 |
Fundamental Measurements | Line to neutral voltage RMS Line to line voltage RMS Line current RMS Active power Reactive power Apparent power Power factor |
maximumimum/Minimum | maximumimum/minimum of RMS Power and power factors Fundamental measurements records with timestamp |
Demand | Algorithms: Block and rolling window Log peak demand and peak demand time Current demand for each phase and system Per phase and system active power demand: Import/export/net/total Four-quadrant Per phase and system reactive power demand: Import/export/net/total Four-quadrant Per phase and system apparent power demand: Total Four-quadrant |
Energy (per phase and system) | Active energy, IEC 62053-22 Class 0.1S: Import/export/net/total Four-quadrant Reactive energy, IEC 62053-24 Class 0.5S: Import/export/net/total Four-quadrant Per phase and system Apparent energy, IEC 61557-12 Class 0.2: Total Four-quadrant |
TOU Energy and Demand | For system import active energy, import reactive energy, and apparent energy: Up to 8 tariff rates Record maximumimum power demand of billing period Record current and up to 12 historic billing periods |
Power Quality Measurements | Positive/negative/zero sequence for current and voltage Phase angle for current and voltage Harmonics magnitude and angle for current and voltage, up to 127th Flicker |
Communications | |
Communication Interfaces | 2 x Ethernet ports (100BASE-TX) with IEEE1588 support: RJ45 connector, CAT5/5e/6/6a cable 1 Wi-Fi (802.11 b/g/n 2.4 GHz) 1 RS485 port: Baud rates of 2400 to 115,200, pluggable screw terminal connector 1 USB-C port 1 IRIG-B port |
Time Synchronization | NTP PTP IRIG-B |
Serial Port Protocols | Modbus RTU |
Web Server | HTTP/HTTPS |
Ethernet Port Protocols | IPv4, IPv6, DHCP, DNS Modbus TCP, DNP3 TCP, IEC 61850, SNMP, BACnet/IP, PMU (IEEE C37.118) Data post with HTTP(s)/FTP/SFTP/SMPT/SMPT E-mail File download with HTTP(s)/SFPT |
Electrical Characteristics | |
Power Supply | 50/60 Hz, 100 to 415 V AC/100 to 300 V DC |
AC Voltage Inputs | Accuracy range: 10 to 400 VLN, 690 VLL Pickup: 5 V Overload: 1500 V AC continuously; 2500 V AC, 50/60 Hz 1 minute Measurement category: III Frequency range: 40 to 70 Hz (50/60 Hz nominal) |
AC Current Inputs | Nominal current: 1 or 5 A Accuracy range: 1 A nominal: 10 mA to 2 A 5 A nominal: 50 mA to 10 A Pickup: 1 A nominal: 0.5 mA 5 A nominal: 2.5 mA Surge: 20 A continuous, 50 A at 10 second/hour, 500 A at 1 second/hour |
Input and Output (meter base) | 4 digital inputs: Input voltage range: 20 to 150 V AC/DC Input current (maximum): 2.5 mA Start voltage: 15 V Stop voltage: 5 V Pulse frequency (maximum): 100 Hz, 50% duty ratio (5ms ON and 5ms OFF) SOE resolution: 2ms 1 digital output: Dry contact Voltage range: 30 V DC Load current: 60 mA (maximum) Output frequency: 50 Hz, 50% duty ratio (20ms ON, 20ms OFF) Isolation voltage: 5000 V AC |
I/O Modules (up to 3, sold separately) | Digital input: Input voltage range 20 to 160 V AC/DC Input current (maximum) 2 mA Start voltage 15 V Stop voltage 5 V Pulse frequency (maximum) 100 Hz, 50% duty ratio SOE resolution 2ms Digital output (DO) (Photo-MOS): Voltage range 0 to 250 V AC/DC Load current 100 mA(maximum) Output frequency 25 Hz, 50% duty ratio Isolation voltage 2500 V AC Relay output (RO): Switching voltage (maximum) 250 V AC, 30 V DC Load current 5 A(R), 2 A(L) Set time 10ms (maximum) Contact resistance 30 mΩ (maximum) Isolation voltage 2500 V AC Analog output (AO): Output range 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (optional) Accuracy 0.5% Temperature drift 50 ppm/°C typical Isolation voltage 500 V DC Open circuit voltage 15 V Analog input (AI): Input range 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (optional) Accuracy 0.2% Temperature drift 50 ppm/°C typical Isolation voltage 500 V DC |
Mechanical Characteristics | |
Outlines Standard | DIN 43700, ANSI C39.1 Round or square, 3.6 x 3.6" (92 x 92 mm) |
IP Degree of Protection | IP 54: panel mount and touchscreen display, front IP 30: panel mount rear, DIN rail mount, I/O modules |
Environmental Conditions | |
Temperature | Operating: -13 to 158°F (-25 to 70°C) Storage: -40 to 158°F (-40 to 70°C) |
Pressure | Normal |
Humidity | 5 to 95% RH non-condensing |
Altitude | 9842.5' (3000 m) |
Pollution Degree | 2 |
Location/Mounting | Indoor use only |
Electromagnetic Compatibility | |
Immunity to Fast Transients | IEC 61000-4-4: Power, input/output, voltage/current circuits: ±4 kV (5 kHz) Communication: ±4 kV (5 kHz) |
Immunity to Ring Waves | IEC 61000-4-12: Power, input/output, voltage/current circuits: 2.5 kV Communication: 2.5 kV |
Immunity to Electrostatic Discharge | IEC 61000-4-2: Contact discharge: ±4 kV Air discharge: ±8 kV |
Immunity to Voltage Dips and Interruptions | IEC 61000-4-11: 70%, 20 ms 0%, 100 ms |
Immunity to Power Frequency and Magnetic Fields | IEC 61000-4-8: 100 A/m, 1 minute 1000 A/m, 3 seconds |
Immunity to Surges | IEC 61000-4-5: Power, voltage/current circuits: ±4 kV Input/output: 2 kV Communication: 2 kV |
Immunity to Radiated Fields | IEC 61000-4-3: 80 to 1000 MHz: 10 V/m 1 to 2.7 GHz: 3 V/m 2.7 to 6.0 GHz: 1 V/m |
Immunity to Conducted Disturbances | IEC 61000-4-6: 150 kHz to 80 MHz: 10 V |
Immunity to Power Frequency Disturbances | IEC 61000-4-16: 30 V: 1 minute 300 V: 1 s |
Immunity to Damped Oscillatory Wave | IEC 61000-4-18: AC: 2.5 kV (common mode, 1 MHz) 1 kV (differential mode, 1 MHz) 1 kV (differential mode, 10 MHz) DC: 2.5 kV (common mode, 1 MHz) 1 kV (differential mode, 1 MHz) 1 kV (differential mode, 10 MHz) IO: 2.5 kV (common mode, 1 MHz) 1 kV (differential mode, 1 MHz) |
Radiated Emissions | CISPR 32 Class B |
Click on a category to view a selection of compatible accessories with the Accuenergy Acuvim 3 Series Advanced Power Quality Meter with panel mount and display, 333 mV, AC/DC.