The multi-circuit power metering system monitors kWh, power, energy, demand, peak demand, and time-of-use in high-density applications. It is best used for tenant submetering, commercial facilities, as well as branch circuit monitoring of multiple units.
The multi-circuit power metering system monitors kWh, power, energy, demand, peak demand, and time-of-use in high-density applications. It is best used for tenant submetering, commercial facilities, as well as branch circuit monitoring of multiple units.
Discontinued!
This product has been discontinued and is no longer available.
There is no direct replacement, however we recommend the:
Not what you're looking for? Let’s do a search and help you find what you need.
Features
Applications
| Measure | |
| kWh | Accuracy ± (%rdg): 0.5 seconds Range: 0 to 999999.9 kwh |
| V | Accuracy ± (%rdg): 0.5% Range: 10 to 400 V |
| I | Accuracy ± (%rdg): 0.5% Range: 5 mA to 10000 A |
| P | Accuracy ± (%rdg): 0.5% Range: 4000.0 kW |
| Q | Accuracy ± (%rdg): 0.5% Range: 4000.0 kvar |
| S | Accuracy ± (%rdg): 0.5% Range: 4000.0 kVA |
| PF | Accuracy ± (%rdg): 0.5% Range: -1.000 to 1.000 |
| Freq | Accuracy ± (%rdg): 0.2% Range: 45 to 65 Hz |
| Active Power Demand | Accuracy ± (%rdg): 0.5% Range: 4000.0 kW |
| Current Demand | Accuracy ± (%rdg): 0.5% Range: 5 mA to 10000 A |
| Harmonic | Accuracy ± (%rdg): 1% Range: 0 to 100% |
| Unbalance | Accuracy ± (%rdg): 1% Range: 0 to 100% |
| Meter Running Time | Range: 0 to 999999.9 hours |
| Digital Input (DI) | |
| Input | Style: Dry node Current (maximum): 2 mA Voltage range: 15 to 30 V |
| Voltage | Start: 12 V Stop: 10 V |
| Pulse Frequency (MAX | 100 Hz, 50% duty cycle |
| SOE Resolution | 2 ms |
| Auxiliary Power of DI | |
| Output Voltage | 24 VDC |
| Rated Power | 1 W |
| Digital Output (DO) (Photo-MOS) | |
| Voltage | Range: 0 to 250 VAC-DC Isolation: 2500 VAC |
| Load Current | 100 mA (maximum) |
| Output Frequency | 25 Hz, 50% duty ratio (20 ms ON, 20 ms OFF) |
| Operating Environment | |
| Temperature | Operation: -13 to 158°F (-25 to 70°C) Storage: -40 to 185°F (-40 to 85°C) |
| Humidity | 5 to 95% non-condensing |
| Altitude | 3000 m |
| Power Supply | |
| Operating Range | 100 to 415 VAC, 50 to 60 Hz; 100 to 300 VDC |
| Burden | 10 VA |
| Measure | |
| kWh | Accuracy ± (%rdg): 0.5 seconds Range: 0 to 999999.9 kwh |
| V | Accuracy ± (%rdg): 0.5% Range: 10 to 400 V |
| I | Accuracy ± (%rdg): 0.5% Range: 5 mA to 10000 A |
| P | Accuracy ± (%rdg): 0.5% Range: 4000.0 kW |
| Q | Accuracy ± (%rdg): 0.5% Range: 4000.0 kvar |
| S | Accuracy ± (%rdg): 0.5% Range: 4000.0 kVA |
| PF | Accuracy ± (%rdg): 0.5% Range: -1.000 to 1.000 |
| Freq | Accuracy ± (%rdg): 0.2% Range: 45 to 65 Hz |
| Active Power Demand | Accuracy ± (%rdg): 0.5% Range: 4000.0 kW |
| Current Demand | Accuracy ± (%rdg): 0.5% Range: 5 mA to 10000 A |
| Harmonic | Accuracy ± (%rdg): 1% Range: 0 to 100% |
| Unbalance | Accuracy ± (%rdg): 1% Range: 0 to 100% |
| Meter Running Time | Range: 0 to 999999.9 hours |
| Digital Input (DI) | |
| Input | Style: Dry node Current (maximum): 2 mA Voltage range: 15 to 30 V |
| Voltage | Start: 12 V Stop: 10 V |
| Pulse Frequency (MAX | 100 Hz, 50% duty cycle |
| SOE Resolution | 2 ms |
| Auxiliary Power of DI | |
| Output Voltage | 24 VDC |
| Rated Power | 1 W |
| Digital Output (DO) (Photo-MOS) | |
| Voltage | Range: 0 to 250 VAC-DC Isolation: 2500 VAC |
| Load Current | 100 mA (maximum) |
| Output Frequency | 25 Hz, 50% duty ratio (20 ms ON, 20 ms OFF) |
| Operating Environment | |
| Temperature | Operation: -13 to 158°F (-25 to 70°C) Storage: -40 to 185°F (-40 to 85°C) |
| Humidity | 5 to 95% non-condensing |
| Altitude | 3000 m |
| Power Supply | |
| Operating Range | 100 to 415 VAC, 50 to 60 Hz; 100 to 300 VDC |
| Burden | 10 VA |