TPI 712 Combustion Analyzer with pump and soft case

TPI 712
TPI Store

View TPI Products Visit TPI Store

No Reviews yet for this product

MFG Part # TPI 712
Condition New
Our price $849.95

Accurately test flue gases in furnaces and domestic boilers to determine operation efficiency. Time/date documentation for future reference.

  • Fast and easy set-up
  • Fast purge and fuel selection during start-up reduces set-up time
  • Measures CO, O2, pressure,and temperature
  • Calculates CO2and gross ornet efficiency
  • Works on High Efficiencyfurnace
  • Selectable fuels: natural gas, light oil, heavy oil, LPG, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
  • Pump driven for fast response
  • Dual input differential manometer with 3 selectable units of measure: kPa,mBar, inH2O, .001 inH20resolution
  • Tightness test: check forpressure leaks in valves, fittings, and switches with anelapsed time reference
  • Flue probe with built-in thermocouple
  • IR printer port - use optionalA740 Infrared Printer.
  • Soft carrying case
  • Protective rubber boot


Applications:

  • Tuning of residential and furnaces and domestic boilers
  • Ambient and stack testing for CO
  • CO safety measurements in and around combustion sources
  • Temperature checking, including superheat and hydronic differential temperatures
  • Detecting gas leak in gas lines and around gas fueled appliances. Dual input differential manometer with 3 selectable units of measure: kPa, mBar,inH20


Specifications:

  • Carbon Monoxide (CO) Measurement      Range 0 to 10,000 ppm, Resolution 1 ppm, Accuracy +/-5ppm or 5% of reading whichever is greater
  • Oxygen (02) Measurement     Range 0 to 25%, Resolution 0.1%, Accuracy ±0.3%
  • Carbon Dioxide (CO2)     Range 0 to 25%, Resolution 0.1%, Accuracy Calculated
  • Nitric Oxide Measurement     N/A
  • NOX Measurement     N/A
  • Temperature Measurement     Range -40 to 1472°F, or -40 to 800°C, Resolution 1°F or °C, Accuracy (K-type) ±0.3%, ±2°F or ±1°C
  • Draft/Pressure Measurement     Selectable Ranges mBar,kPa, and inH2O Ranges -150 mBar to +150 mBar -15 kPa to +15 kPa -60 inH2O to +60 in H20, Resolution 0.01mBar, Accuracy ±0/5% fsd
  • Gross/Net Efficiency     Range 0 to 100%, Resolution 0.1%, Accuracy Calculated
  • CO/CO2 Ratio     Range 0 to 0.999, Resolution 0.001, Accuracy Calculated
  • Combustible Gas Level Indication     Yes (For flue gasses)
  • Operating Temperature     14°F to 122°F (-10°C to 50°C)
  • Charger Input Voltage    110V to 230V (50/60Hz)
  • Selectable Fuels     Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
  • Display Type     Backlit 3 line LCD
  • Data Storage     50 Locations
  • Data Logging     Yes (5 pages)
  • Print Capability     Yes, via optional IR printer (A740)
  • PC Communication     Yes via optional IR adapter (A767)
  • Date & Time Function     24 Hour Real Time Clock
  • Dimensions     200mm x 90mm x 60mm
  • Weight     500g
  • Conformity     BS7927 (and the draft BS7967)